张戈军
中国医学科学院阜外医院 放射科
BACKGROUND:Severe degenerative mitral regurgitation (DMR) can cause a poor prognosis if left untreated. For patients considered at prohibitive surgical risk, transcatheter edge-to-edge repair (TEER) has become an accepted alternative therapy. The DragonFly transcatheter valve repair system is an innovative evolution of the mitral TEER device family to treat DMR.AIMS:Herein we report on the DRAGONFLY-DMR trial (ClinicalTrials.gov: NCT04734756), which was a prospective, single-arm, multicentre study on the safety and effectiveness of the DragonFly system.METHODS:A total of 120 eligible patients with prohibitive surgical risk and DMR ≥3+ were screened by a central eligibility committee for enrolment. The study utilised an independent echocardiography core laboratory and clinical event committee. The primary endpoint was the clinical success rate, which measured freedom from all-cause mortality, mitral valve reintervention, and mitral regurgitation (MR) >2+ at 1-year follow-up.RESULTS:At 1 year, the trial successfully achieved its prespecified primary efficacy endpoint, with a clinical success rate of 87.5% (95% confidence interval: 80.1-92.3%). The rates of major adverse events, all-cause mortality, mitral valve reintervention, and heart failure hospitalisation were 9.0%, 5.0%, 0.8%, and 3.4%, respectively. MR ≤2+ was 90.4% at 1 month and 92.0% at 1 year. Over time, left ventricular reverse remodelling was observed (p<0.05), along with significant improvements in the patients' functional and quality-of-life outcomes, shown by an increase in the New York Heart Association Class I/II from 32.4% at baseline to 93.6% at 12 months (p<0.001) and increased Kansas City Cardiomyopathy Questionnaire (KCCQ) score of 31.1±18.2 from baseline to 12 months (p<0.001).CONCLUSIONS:The DRAGONFLY-DMR trial contributes to increasing evidence supporting the safety and efficacy of TEER therapy, specifically the DragonFly system, for treating patients with chronic symptomatic DMR 3+ to 4+ at prohibitive surgical risk.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology 2024
BACKGROUND:Quadricuspid aortic valve (QAV) is a rare congenital heart disease with a limited body of literature. This retrospective cohort study investigates QAV morphology, function, and clinical outcomes.METHODS:Echocardiography was used to assess valvular function. Morphological characteristics such as phenotypes, raphe, regurgitant orifice area (ROA), and aortic dilation (diameter >40 mm) were assessed by cardiac CT. Patients were followed up for the combined event of all-cause death and aortic valve replacement (AVR).RESULTS:Ninety QAV patients (screened from 322385 CT scans) were included (mean age 55.2 ± 13.6 years, 61.1 % male). Isolated significant aortic regurgitation (AR) was present in 75.6 % of patients. The cohort was dominated by type I (four equal leaflets, 37.8 %) and type II (3 larger and 1 smaller leaflets, 42.2 %) QAV. Fused raphe was present in 26.7 % of patients. ROACT was correlated with AR severity and aortic dilation (41.1 %, n = 37). Among patients without AVR at baseline (n = 60), one died and 17 underwent AVR during a median follow-up of 35.0 months (IQR:17.3-62.8). ROACT was associated with an increasing risk of combined event (as a categorical variable with a cut-off of 21.4 mm2, HR = 4.25, 95%CI 1.49-12.17, p = 0.007; as a continuous variable (per mm2 increment), HR = 1.04, 95%CI 1.01-1.07, p = 0.003). Additionally, ROACT had incremental prognostic value when added to the AR severity model (area under the receiver-operating characteristic curve increased from 86.8 to 88.4, p = 0.004).CONCLUSION:QAV is characterized by variable anatomy, progressive AR, concomitant cusp fusion and aortic enlargement. ROACT may be a potential ancillary prognostic marker in patients with QAV.
Journal of cardiovascular computed tomography 2024
Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2024
Although the use of bioabsorbable occluder is expected to reduce the risk of metal occluder-related complications, it has not been approved due to incomplete degradation and new complications. Novel fully bioabsorbable occluders were designed to overcome such limitations. The aim of this study was to investigate the efficacy and safety of a fully biodegradable occluder in patients with ventricular septal defects. 125 patients with perimembranous ventricular septal defect (VSD) larger than 3 mm were screened from April 2019 to January 2020 in seven centers. 108 patients were enrolled and randomized into the bioabsorbable occluder group (n = 54 patients) and nitinol occluder group (n = 54). A non-inferiority design was utilized and all patients underwent transcatheter device occlusion. Outcomes were analyzed with a 24-month follow-up. All patients were successfully implanted and completed the trial. No residual shunt >2 mm was observed during follow-up. Transthoracic echocardiography showed a hyperechoic area corresponding to the bioabsorbable occluder which decreased primarily during the first year after implantation and disappeared within 24 months. Postprocedural arrhythmia was the only occluder-related complication with an incidence of 5.56% and 14.81% for the bioabsorbable and nitinol groups, respectively (P = 0.112). The incidence of sustained conduction block was lower in the bioabsorbable occluder group (0/54 vs. 6/54, P = 0.036) at 24-month follow-up. In conclusion, the novel fully bioabsorbable occluder can be successfully and safely implanted under echocardiography guidance and reduce the incidence of sustained postprocedural arrythmia. The efficacy and safety of this fully biodegradable occluder are non-inferior to that of a traditional nitinol one.
Science bulletin 2023
BACKGROUND:Coronary arteries drain into the left ventricle, known as coronary-left ventricular fistula (CLVF), an extremely rare anomalous coronary artery disease. Little is known about the outcomes following transcatheter closure (TC) or surgical closure (SC) of CLVF.METHOD:This was a single-center retrospective study including 42 consecutive patients who underwent either the TC or SC procedure from January 2011 to December 2021. The baseline and anatomic characteristics of the fistulas, procedural outcomes, and late outcomes were summarized and analyzed.RESULTS:The mean age was 31.6 ± 16.2 years, with 28 male patients (66.7%). Fifteen patients underwent SC group and the remaining received TC group. There were no differences in age, comorbidities, clinical presentations, and anatomic characteristics between the 2 groups. The procedural success rate was similar (93.3% vs. 85.2%, P = 0.639) without operative and in-hospital mortality in both groups. Notably, patients who underwent TC had a significantly shorter postoperative in-hospital length of stay (2.11 ± 1.49 vs. 7.73 ± 2.37 days, P<0.001). The median follow-up time was 4.6 years (2.5-5.7 years, TC group) and 3.98 years (0.42-7.15 years, SC group), respectively. No difference was observed in the incidence of recanalization of the fistula (7.4% vs. 6.7%, P = 1) and myocardial infarction (0% vs. 0%). Cerebral infarction due to discontinuation of anticoagulants happened to two patients in the TC group. Importantly, thrombotic occlusion of the fistulous tract with patent parent coronary artery was found in 7 patients of the TC group.CONCLUSION:Both transcatheter and SC are safe and effective for patients with CLVF. Thrombotic occlusion is a noteworthy late complication, and its presence indicates the use of anticoagulants lifelong.
Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese 2023
Background:Data on outcomes following transcatheter aortic valve replacement with SAPIEN 3 in China is limited as it was approved by the National Medical Products since 2020. The present study was designed to collect clinical data on the SAPIEN 3 aortic valve in Chinese patients with bicuspid aortic valve and tricuspid aortic valve stenosis.Methods:We analyzed the patient characteristics, procedural features and procedural outcomes of the first 438 patients (223 for bicuspid aortic valve and 215 tricuspid aortic valve) from 21 provinces in 74 sites treated with the SAPIEN 3 valve system for transcatheter aortic valve replacement between September 2020 and May 2022.Results:Procedural mortality was 0.7%. 5 cases during the operation were converted to surgery. Among 438 cases, permanent pacemaker implantation was performed in a total of 12 cases (2.7%). The patient had severe leaflet calcification of the aortic valve, with moderate and severe calcification reaching 39.7% and 35.2% respectively. The size of the implanted valves was predominantly 26 mm and 23 mm, reaching 42.5% and 39.5% respectively. The incidence of moderate or severe perivalvular leak in the postoperative period was 0.5%, with a predominance of 90/10 and 80/20 valve deployment height. There was a significant difference in the deployment height of the valve between bicuspid aortic valve and tricuspid aortic valve, with the bicuspid aortic valve having a more deployment height of 90/10. Annulus size in bicuspid aortic valve group was significantly larger than tricuspid aortic valve group. Valve sizing for oversized, within size, and undersized were different between bicuspid aortic valve and tricuspid aortic valve.Conclusions:Procedural success rates were high, with similar and good results for bicuspid aortic valve and tricuspid aortic valve, low perivalvular leak for both valve types, and low permanent pacemaker implantation rates for both valve types. Annulus size, valve sizing and coronary artery height were significantly different in the BAV and TAV group.
Frontiers in cardiovascular medicine 2023
BACKGROUND:Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve.METHODS:Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University.RESULTS:3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) (n = 2) or risk of compression coronary artery (n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001).CONCLUSIONS:In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.
Chinese medical journal 2023
JACC. Cardiovascular interventions 2022
Development of major aortopulmonary collateral arteries are strongly associated with cyanotic congenital heart disease. However, they have rarely been reported in noncyanotic congenital heart disease. We report a rare case of a newborn originally diagnosed with an atrial septal defect, a ventricular septal defect, and pulmonary arterial hypertension who underwent complete repair. Failure to progress postoperatively lead to the delayed diagnosis of aortopulmonary collateral arteries. Percutaneous embolization and surgical ligation of aortopulmonary collateral arteries resulted in rapid recovery.
The Annals of thoracic surgery 2022
the early and med-term follow-up results and technical points of new re-dilated stent in the treatment of pulmonary artery bifurcation opening stenosis, and explore its feasibility and advantages. From March 2019 to October 2020, 10 children [5 males, mean age (7±3) years], mean weight 18.75(13.35,23.05) kg with pulmonary artery bifurcation opening stenosis were treated with new re-dilated stents in the Central China Fuwai Hospital. Including 5 cases of tetralogy of Fallot, 4 cases of pulmonary atresia, 1 case of anomalous origin of coronary artery, all children were given new re-dilated stent implantation. Echocardiography, chest X-ray and electrocardiogram were performed 1 day, 3, 6, 12 months after intervention. Pulmonary artery CTA was performed after 6 or 12 months to evaluate the results, including restenosis, malposition and rupture. A total of 16 stents were implanted in 10 children, 5 cases had simultaneous stenosis of bifurcation openings of pulmonary arteries, and 1 stent was implanted in each of the left and right pulmonary artery openings. The pressure of right ventricular and gradient was significantly decreased immediately after intervention, from preoperative (38-80) mmHg(1 mmHg=0.133 kPa) to postoperative (0-22) mmHg, only one patient's pressure gradient is over 20 mmHg (22 mmHg), and all cases discharged successfully. Stent restenosis, malposition, fracture and other abnormalities were not observed in follow-up. Stents implantation for patients with pulmonary artery bifurcation opening stenosis is very more difficult. A good strategy can ensure that the intervention is safe and effective. It not only avoids the risk of repeated surgery, but also achieves good med-term follow-up results.
Zhonghua yi xue za zhi 2022