Comparison of immediate changes of repolarization parameters after left bundle branch area pacing and traditional biventricular pacing in heart failure patients.

6.1
3区
第一作者

Chinese medical journal 2023

Quantitative analysis reveals influencing factors to facilitate successful anodal-ring capture in left bundle branch pacing.

AIMS:Left bundle branch pacing (LBBP) maintains left ventricular synchrony but induces right ventricular conduction delay (RVCD). Although anodal-ring capture (ARC) during bipolar LBBP improves RVCD, it is not achieved in all patients receiving LBBP. This study aimed to analyze the factors influencing ARC implementation.METHODS AND RESULTS:Patients receiving LBBP with intraoperative ARC testing were enrolled. Electrocardiographic parameters were measured, including stimulus-to-QRS duration (stim-QRSd), stimulus-to-left/right ventricular activation time (stim-LVAT/RVAT), and V6-V1 interpeak interval. The distribution of lead-tip sites was described as the corrected longitudinal and lateral distance (longit-/lat-dist). Relative angles of the LBBP lead were measured. Echocardiography in short-axis view was used to measure the intraseptal lead length. Intergroup comparisons, correlation analysis, and stepwise logistic regression were performed. In total, 105 patients were included, among which 65 (62%) patients achieved ARC at a pacing output ≤ 5.0 V/0.5 ms (average 3.1 V/0.5 ms). Anodal-ring capture further shortened the stim-QRSd by 13.1 ± 7.5 ms. Better unipolar-ring (cathodal) threshold and R-wave sensing in LBBP-ARC group indicated the critical role of ring-septum contact in ARC. Longer corrected longit-dist and shorter corrected lat-dist of lead-tip sites were positively correlated with higher success likelihood of ARC, likely due to the greater relative angle in which the lead enters the septum and consequently the longer intraseptal lead length and better ring-septum contact.CONCLUSION:This study elucidated the factors affecting the success likelihood of LBBP-ARC. These findings improve the understanding of LBBP-ARC, providing references for future research and clinical practice.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2023

Distance between the lead-implanted site and tricuspid valve annulus in patients with left bundle branch pacing: Effects on postoperative tricuspid regurgitation deterioration.

BACKGROUND:Left bundle branch pacing (LBBP) is an alternative strategy for His-bundle pacing (HBP); however, little is known about tricuspid regurgitation (TR) deterioration after LBBP implantation.OBJECTIVES:The purpose of this study was to characterize the incidence of post-LBBP TR deterioration and identify predicting factors, especially lead position parameters.METHODS:Patients who received LBBP were continuously enrolled from January 2018 to August 2020. The progression of TR and the anatomic position of LBBP were characterized by echocardiography.RESULTS:A total of 89 patients were enrolled and assigned to 2 subgroups based on the degree of TR before LBBP implantation: 58 (65.2%) with relatively normal tricuspid valve (TV) function (grade 0/1 subgroup: with none/trivial or mild TR) and 31 (34.8%) with more severe TR (grade 2/3 subgroup: with moderate or severe TR). At 19.0 ± 6.5 months of follow-up, 29 patients (32.6%) had TR deterioration, and 23 of them were in the grade 0/1 subgroup. In the grade 0/1 subgroup, patients with TR deterioration had a shorter distance between the lead-implanted site and TV (Lead-TA-dist) than those without TR (19.0 ± 7.6 vs 23.9 ± 5.4; P = .006). The receiver operating characteristic (ROC) curve (area under the curve 0.721; 95% confidence interval [CI] 0.575-0.867; P = .005) indicated the favorable efficacy of Lead-TA-dist for predicting TR deterioration after LBBP. Lead-TA-dist ≤16.1 mm was independently associated with TR deterioration after LBBP (hazard ratio 0.20; 95% CI 0.06-0.76; P = .017).CONCLUSION:TR was a common complication of LBBP implantation. In patients with none/trivial or mild TR, Lead-TA-dist ≤16.1 mm was an independent predictor of TR deterioration after LBBP implantation.

5.5
2区

Heart rhythm 2023

Changes of repolarization parameters after left bundle branch area pacing and the association with echocardiographic response in heart failure patients.

Background: Left bundle branch area pacing (LBBAP) has become a safe and effective option for heart failure (HF) patients indicated for cardiac resynchronization therapy (CRT) and/or ventricular pacing, yet the response rate was only 70%. Repolarization parameters were demonstrated to be associated with cardiac mechanics and systolic function. This study aimed to investigate the effects of LBBAP on repolarization parameters and the potential association between those parameters and echocardiographic response. Methods and results: A total of 59 HF patients undergoing successful LBBAP were consecutively included. QTc, Tpeak-Tend (TpTe), and TpTe/QTc were measured before and after the implantation. The results turned out that the dispersion of ventricular repolarization (DVR) improved after LBBAP among the total population. Although trends of repolarization parameters varied according to different QRS configurations at baseline, the post-implant parameters showed no significant difference between groups. The association between repolarization parameters and LBBAP response was then evaluated among patients with wide QRS. Multivariate analysis demonstrated that post-implant TpTe was the independent predictor of LBBAP response (p < 0.05). Receiver operating characteristic analysis indicated an area under the curve of 0.77 (95% CI, 0.60-0.93) with a cutoff value of 81.2 ms (p < 0.01). Patients with post-implant TpTe<81.2 ms had a significantly higher rate of echocardiographic response (93.3 vs. 44.4%, p < 0.01). Further subgroup analysis indicated that the predictive value of post-implant TpTe for LBBAP response was more significant in non-left bundle branch block (LBBB) patients than in LBBB patients. Conclusion: LBBAP improved DVR significantly in HF patients. Post-implant TpTe was associated with the echocardiographic response after LBBAP among patients with wide QRS, especially for non-LBBB patients.

4.0
3区
第一作者

Frontiers in physiology 2022

Long-term follow-up results of patients with left bundle branch pacing and exploration for potential factors affecting cardiac function.

Background: Left bundle branch pacing (LBBP) is an alternative strategy for His bundle pacing (HBP). This study aimed to analyze the long-term performance of LBBP and the potential factors affecting long-term cardiac function. Methods: Patients with LBBP were continuously enrolled from January 2018 to August 2020. Pacing parameters, electrocardiogram (ECG), and echocardiography were collected. The anatomic position of LBBP leads was described by echocardiographic and fluoroscopic parameters. Results: A total of 91 patients with a median follow-up of 18 months were enrolled. Most patients maintained stable pacing parameters during follow-up. The intra-septal position of the 3830 lead also remained stable as the distance from the lead tip to the left surface of the ventricular septum was 0.4 (0, 1.4) mm. The overall level of left ventricular ejection fraction (LVEF) slightly increased. 59 patients had improved LVEF (∆LVEF > 0), while 28 patients had unchanged or reduced LVEF (∆LVEF ≤ 0). The declines of baseline LVEF, ∆ Paced QRSd, and corrected longitudinal distance (longit-dist) of lead-implanted site correlated with LVEF improvement, and these three factors had negative linear correlations with ∆LVEF. Patients with tricuspid valve regurgitation (TVR) deterioration had longer follow-up duration (20.5 vs. 15.0 months, p = 0.01) and shorter Lead-TVA-dist (18.6 vs. 21.6 mm, p = 0.04) than those without TVR deterioration. Conclusion: Patients with LBBP generally remained stable in pacing performance, anatomic lead positions, and cardiac function in long-term follow-up. Baseline LVEF, ∆ Paced QRSd, and corrected longit-dist might be associated with potential LVEF decrease, which required further confirmation.

4.0
3区

Frontiers in physiology 2022

Quantitative distance and electrocardiographic parameters for lead-implanted site selection to enhance the success likelihood of left bundle branch pacing.

BACKGROUND:Left bundle branch pacing (LBBP) is a novel near-physiological pacing method that still lacks quantitative criteria to guide the selection of lead-implanted sites to enhance the success likelihood of lead deployments. This study aimed to quantitatively analyze the relationships of LBBP success likelihood to the distribution of lead-implanted sites and the lead-localization-pacing electrocardiographic (ECG) features.METHODS:All the lead-implanted sites in patients with finally successful LBBP were enrolled for analysis, including successful and failed sites. A novel coordinate system was invented to describe the sites' distribution as longitudinal distance (longit-dist) and lateral distance (lat-dist). Corrected distance parameters were generated to eliminate the cardiac dimension variations. The lead-localization-pacing ECG parameters were also collected, such as paced QRS duration (locat-QRSd), left ventricular activation time (locat-LVAT), LVAT/QRSd ratio (locat-LVAT/QRSd), and QRS directions.RESULTS:A total of 94 patients with 105 successful sites and 93 failed sites were enrolled. Longit-dist and corrected longit-dist of successful sites were significantly longer, while locat-QRSd and locat-LVAT were shorter and locat-LVAT/QRSd was lower than failed sites. There was a positive dose-response relationship between LBBP success likelihood and corrected longit-dist with a cut-off of 26.95 mm, whereas there were negative dose-response relationships of LBBP success likelihood to locat-QRSd, locat-LVAT, and locat-LVAT/QRSd with the cut-offs of 142 ms, 92 ms, and 64.7%, respectively. Downward QRS direction in II/III ECG leads was also associated with successful LBBP.CONCLUSION:Longit-dist, locat-QRSd, locat-LVAT, and locat-LVAT/QRSd were quantitative parameters to guide the selection of lead-implanted sites during LBBP implantation. Quantitative distance and electrocardiographic parameters for lead-implanted site selection to enhance the success likelihood of left bundle branch pacing. LBBP, left bundle branch pacing; Longit-dist, longitudinal distance; CL-apex-dist, distance from contraction line to apex; LBBB, left bundle branch block; IVCD, intraventricular conduction delay; Locat-QRSd, lead-localization-pacing QRS duration; Locat-LVAT, lead-localization-pacing left ventricular activation time; Locat-LVAT/QRSd, lead-localization-pacing LVAT/QRSd ratio.

5.0
2区

Clinical research in cardiology : official journal of the German Cardiac Society 2022

Relationship of paced left bundle branch pacing morphology with anatomic location and physiological outcomes.

BACKGROUND:Left bundle branch pacing (LBBP) is an emerging physiological pacing modality. However, little is known about pacing at different locations on the left bundle branch (LBB).OBJECTIVE:The purpose of this study was to explore pacing and physiological characteristics associated with different LBBP locations.METHODS:The study included 68 consecutive patients with normal unpaced QRS duration and successful LBBP implantation. Patients were divided into 3 groups according to the paced QRS complex as left bundle branch trunk pacing (LBTP), left posterior fascicular pacing (LPFP), or left anterior fascicular pacing (LAFP). Electrocardiographic (ECG) characteristics, pacing parameters, and fluoroscopic localization were collected and analyzed.RESULTS:There were 17 (25.0%), 35 (51.5%), and 16 (23.5%) patients in the LBTP, LPFP, and LAFP groups, respectively. All subgroups had relatively narrow paced QRS complex (128.6 ± 9.1 ms vs 133.7 ± 11.2 ms vs 134.8 ± 9.6 ms; P = .170), fast left ventricular activation (70.4 ± 9.0 ms vs 70.6 ± 10.2 ms vs 71.0 ± 9.0 ms; P = .986), as well as low and stable pacing thresholds. Delayed right ventricular activation and interventricular dyssynchrony were similar between groups. Fluoroscopic imaging indicated that the lead tip was located most commonly in the basal-middle region of the septum (67.7%), and this was independent of paced QRS morphology group (88.2% vs 57.1% vs 68.8%; P = .106).CONCLUSION:Pacing at different sites of the LBB resulted in similar intraventricular and interventricular electrical synchrony in patients with an intact conduction system. Fluoroscopic imaging alone could not predict specific LBBP paced ECG morphology.

5.5
2区

Heart rhythm 2021