薛云飞
中国医学科学院阜外医院 血管外科中心
Objective:This study aimed to summarize the long-term experience of using the chimney technique in thoracic endovascular aortic repair (TEVAR) for aortic arch diseases.Methods:From November 2007 to June 2021, a total of 345 consecutive patients (mean age 56 ± 11.3 years, range 28-83, 302 men) with aortic arch pathologies underwent TEVAR combined with chimney technique (cTEVAR). Their medical data and follow-up results were retrospectively reviewed and analyzed.Results:Among the 345 patients, 278 (80.6%) received single chimneys, 53 (15.4%) received double chimneys, 7 (2%) received triple chimneys, and 7 (2%) underwent cTEVAR accompanied by other techniques (two with extra-anatomical bypass, two with in situ fenestration, and three with physician modified fenestration). A total of 412 chimney stents were used, including 27 in the innominate artery (IA), 113 in the left common carotid artery, 270 in the left subclavian artery, and two in the aberrant right subclavian artery. Early type IA endoleaks were found in 38 (11%) patients, including 12 with the double or triple chimney technique. Early type II endoleak was found in nine (2.6%) patients. Early re-intervention occurred in two patients with double chimney technique, one for chimney stent migration and the other for compression of chimney stent. The 30-day mortality was 1.2% (4 in 345). During a mean follow-up of 42 ± 22 months (range 1-108 months), major stroke occurred in nine (2.6%) patients, chimney occlusion or stenosis occurred in six (1.7%), and retrograde type A aortic dissection occurred in four (1.2%). Fourteen (4.1%) patients received the secondary intervention. The all-cause mortality was 6.7% (23 in 345). Additionally, the total adverse event rate after cTEVAR was 13.9% (48 in 345).Conclusion:TEVAR with chimney technique provides a minimally invasive alternative with good chimney graft patency and low postoperative mortality during follow-up. However, the double and triple chimney techniques should be used cautiously as they seem to have a higher risk for type IA endoleak and adverse events after the operation.
Frontiers in cardiovascular medicine 2022
PURPOSE:To evaluate the safety and feasibility of the in situ needle fenestration (ISNF) technique for reconstruction of the left subclavian artery (LSA) during thoracic endovascular aortic repair (TEVAR) of complicated aortic arch pathologies.MATERIALS AND METHODS:A retrospective review was conducted from January 2014 to December 2019 of 50 patients (mean age 60.2±11.1; 45 men) who underwent ISNF to revascularize the LSA during TEVAR. Twenty-one of the patients also required revascularization of the left common carotid artery (LCCA; n=19) and innominate artery (IA; n=2) using physician-modified in vitro fenestration. Overall, 73 supra-aortic branches were targeted for revascularization.RESULTS:ISNF was successful in 48 patients (96%); one LSA could not be stented and a tortuous LSA prevented the needle from fenestrating the graft. No perioperative major adverse event occurred. There were no type I and 4 type III endoleaks (8%), 3 of which occurred among the first 20 cases. Types II and IV endoleaks were found in 3 (6%) and 6 (12%) cases, respectively; all disappeared during a median follow-up of 15 months (range 3-66). One death (2%) occurred within 12 months due to cerebral hemorrhage. Two patients (4%) required open reinterventions at 6 and 62 months.CONCLUSION:ISNF for revascularization of the LSA during TEVAR seems to be feasible with acceptable midterm outcomes. The learning curve and evolving patient selection criteria affected technical success, complications, and the need for reinterventions. Long-term durability requires further evaluation.
Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists 2021
BACKGROUND:Currently, the thoracic endovascular aortic repair is the recommended clinical treatment for type B aortic dissections. Unfortunately, malperfusion or ischemia of the kidneys is a major complication of type B aortic dissections. Despite this, few studies have focused on the effects of thoracic endovascular aortic repair on blood flow in renal arteries and parenchyma. This current investigation used novel real-time imaging software to quantitatively analyze the hemodynamic changes in renal artery blood flow and perfusion before and after stent graft placement.METHODS:A total of 51 patients with type B aortic dissection undergoing thoracic endovascular aortic repair between April 2017 and September 2019 were retrospectively recruited. The pre-and post-procedural digital subtraction angiography images were converted into color-coded maps using syngo iFlow for quantitative comparison. Time-intensity curves and related parameters, including the average peak ratio (avg.Pr), average delayed time to peak (avg.dTTP), and average area under the curve ratio (avg.AUCr) of the renal arteries and renal cortex were obtained and analyzed. Wilcoxon signed-rank test was used to compare iFlow parameters before and after endovascular repair. Spearman correlation analyses were performed to study iFlow parameters and renal function parameters and the estimated glomerular filtration rate (eGFR) and blood urea nitrogen (BUN).RESULTS:A total of 102 images including 51 pre-operative and 51 post-operative image datasets were successfully post-processed. Following endovascular repair, syngo iFlow showed a significant 33.0% increase in avg.Pr (P<0.001) and a significant 35.1% increase in avg.AUCr (P<0.001) in the renal artery. Additionally, there was a significant 12.2% decrease in the avg.dTTP (P=0.001), a significant 24.5% increase in avg.Pr (P=0.004), and a significant 38.3% increase in avg.AUCr (P=0.009) in the renal cortex. Spearman correlation analysis showed that after endovascular repair there was a significant correlation between the avg.Pr of the renal artery and eGFR (r=0.30; P=0.0349), the avg.Pr of the renal cortex and eGFR (r=0.30; P=0.0300), and the avg. AUCr of the renal cortex and BUN (r=0.31; P=0.0289).CONCLUSIONS:syngo iFlow provided a novel quantitative method for evaluating renal hemodynamic changes in patients with type B aortic dissection undergoing endovascular treatment. Time-intensity curve parameters may facilitate the intraprocedural evaluation of renal blood flow and perfusion to complement the color-coded map.
Quantitative imaging in medicine and surgery 2021
OBJECTIVES:Our study aims to assess the technical quality and the learning curve of the preclosure technique for a vascular surgeon using Proglide using cumulative sum analysis (CUSUM analysis).METHODS:This study was designed retrospectively and enrolled 81 consecutive patients with 88 access sites who underwent endovascular aortic repair or thoracic endovascular aortic repair with the preclosure technique using Proglide between July 2017 and February 2018. The patients were divided into 2 groups chronologically: (A) the first 40 cases and (B) the latter 41 cases. Logistic regression analysis was used to assess the impact of technical risk factors on the success of the preclosure technique, and the χ2 test and 1-way ANOVA were applied to analyse the distribution of individual characteristics and risk factors between the 2 groups. CUSUM analysis was adapted to analyse the learning curve and to monitor the technical quality, with a predetermined target failure rate of 5%, an alternative failure rate of 20% and calculated 80% 'alert', 95% 'alarm' and 80% 'reassurance' lines.RESULTS:Primary technical success was obtained in 81 (92.05%) access sites. There were no significant correlations between primary technical success and risk factors, including, common femoral artery diameter (P = 0.88), common femoral artery depth from the skin (P =0.94), the level of common femoral artery calcification (P =0.86) and size of sheath (P =0.96). Moreover, the distribution of related risk factors was not significantly different between groups A and B. CUSUM analysis showed that the cumulative failure rate never crossed the 80% 'alert' and 95% 'alarm' lines. Additionally, the failure rate began to approach the 80% 'reassurance' line after ∼22 cases and crossed the 80% 'reassurance' line after 36 cases.CONCLUSIONS:The technique of totally percutaneous access using Proglide is safe and effective for an experienced vascular surgeon, even if the operator has no previous experience with any preclosure techniques. CUSUM analysis showed that 36 cases are necessary to achieve the target failure rate of 5%.
Interactive cardiovascular and thoracic surgery 2020
BACKGROUND:Revascularization of the supra-aortic major branches in thoracic endovascular aortic repair (TEVAR) is challenging owing to the complex anatomic configuration of aortic arch pathologies. This study aims to evaluate the feasibility, effectiveness, and safety of three major techniques-chimney, fenestrated, and in-situ fenestration-for patients with aortic arch pathologies.METHODS:A retrospective analysis was performed involving 234 patients with aortic arch lesions, who underwent TEVAR with adaptations in technique (chimney, fenestrated, or in-situ fenestration) between January 2016 and December 2017.RESULTS:One hundred and twenty-six patients underwent the chimney technique (98 single chimneys, 24 double chimneys, and four triple chimneys); one hundred and two patients (102/234) were treated with on-the-table fenestration technique (92 single fenestrations, nine double fenestrations, and one double fenestration plus innominate artery chimney); and the remaining six patients underwent in-situ needle fenestration technique. Overall, indications included aortic dissections (99/234), aortic arch aneurysms (60/234), penetrating aortic ulcers (72/234), and re-interventions (3/234). The technical success rates were 99.6%. There were five cases of early all-cause mortality. The patency rates of overall branches were 99.6%. There were 15 cases with type Ia endoleak-14 in the chimney group (11.1%) and one in the on-the-table fenestration group (1%). Five patients underwent re-interventions. The median follow-up time for all patients was 28 (range, 16-41) months.CONCLUSIONS:Our experience suggests that chimney, on-the-table fenestration, and in-situ needle fenestration techniques are feasible, effective, and safe treatment options for aortic arch pathologies with encouraging mid-term results. Long-term durability concerns require further evaluation.
Journal of thoracic disease 2020
PURPOSE:This report describes first-in-human experiences and early results of gutter-free chimney stent graft implantation for aortic arch pathologies.DESCRIPTION:The gutter-free chimney stent graft consists of an inner stent and an outer skirt fabric to form an integrated structure. The inner and outer layers are nickel-titanium self-expanding skeletal structures with double polytetrafluoroethylene coating. The outer skirt fabric fits the gutter to prevent endoleak, and the proximal inner stent has a larger radial force to ensure the blood flow. All these designs have the advantages to overcome the native defects of current chimney techniques.EVALUATION:We reported 2 patients who were diagnosed as having aortic arch pathologies and received the gutter-free chimney stent graft implantation during thoracic endovascular aortic repair. In all patients, aortic arch lesions were covered, and supraaortic branches were patent without complications after thoracic endovascular aortic repair and during the 17 months of follow-up.CONCLUSIONS:Novel gutter-free chimney stent graft may be safely and effectively utilized for endovascular repair in aortic arch pathologies. Long-term durability should be confirmed by larger studies and ongoing research.
The Annals of thoracic surgery 2020
Background: the plasma D-dimer and fibrinogen which are indicators of coagulation-fibrinolysis system has been reported to be associated with survival in several types of cancers, including RCC. The aim of our study was to assess the prognostic significance of preoperative plasma D-dimer and fibrinogen levels in RCC patients. Methods: Data from 449 patients with RCC were assessed retrospectively. Cutoff value for plasma D-dimer and fibrinogen were tested by the standardized cutoff-finder algorithm. Overall survival (OS) and disease-free survival (DFS) were evaluated using the Kaplan-Meier method. Univariate and Multivariate Cox regression models were further applied for two end points. Results: Multivariate analysis identified increased plasma D-dimer and fibrinogen as independent prognostic factors for OS (D-dimer, P=0.017; Fibrinogen, P=0.049) and DFS (D-dimer, P=0.038; Fibrinogen, P<0.001). Moreover, all the patients were stratified using these two factors in the following ways: (1) Low risk: both level of plasma D-dimer and fibrinogen were no more than cutoff value. (2) Intermediate risk: neither low risk nor high risk, (3) high risk: both level of plasma D-dimer and fibrinogen were higher than cutoff value. This model showed significant predictive power for OS and DFS. Conclusion: preoperatively elevated D-dimer and fibrinogen can be regard as independent predictors for patients' prognosis in RCC. Combining both plasma D-dimer and fibrinogen can improve the prognostic accuracy and easy accessibility in clinical practice.
Journal of Cancer 2019