谭晓越
中国医学科学院阜外医院 功能检测中心
Objective: In order to explore the mechanism of neonatal spontaneous breathing, the difference of oxygen and carbon dioxide between umbilical cord arteries and veins before the start of spontaneous breathing after birth has been analyzed among people. In this part, the related information is analyzed individually. Methods: After all fetal parents signed the informed consent before birth, and before the newborn was born and did not breathe, the umbilical cord was exposed as quickly as possible, and the heparinized arterial indwelling needle was inserted into the umbilical artery and umbilical vein in the direction of newborn and placenta, and then blood was taken continuously. Although dozens of mothers were selected,but only 3 cases were collected from Pua and Puv blood samplers at the same time for blood gas analysis and determination, and the differences and dynamic changes of umbilical vein and umbilical artery were calculated and analyzed. Results: In all 3 none spontaneous breathing newborns,PuvO2 was significantly higher than PuaO2 at the same time (P<0.01), with an average difference of (24.17±7.09) mmHg; while PuvCO2 was significantly lower than PuaCO2 (all P<0.01), with an average difference of (-7.67±3.70) mmHg.The difference of Puv-uaO2 was significantly higher than those of Puv-uaCO2 (P<0.05). Conclusion: PuaO2 decreases gradually with time (heartbeat frequency) before spontaneous breathing after the delivered fetus as a newborn, and it induces the first inhalation to start spontaneous breathing when it reaches the threshold of triggering breathing.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: The fetus has no actual respiration, and the newborn begins to breathe after birth. We assume that the first breath dominantly generated by hypoxia. In this study, the changes and lowest limit of blood oxygen partial pressureof umbilical artery (PuaO2) after chemoreceptor were analyzed to explore the mechanism of neonatal spontaneous breathing. Methods: With signed consent form by all fetal parents before birth, 14 newborns successfully completed the umbilical artery or vein catheterization and drawn blood according to the heartbeat. All blood samples analyzed by blood gas analyzer,calculated and analyzed the similarities and differences between umbilical vein(Puv) and umbilical artery(Pua). Results: Although we completed 14 newborns, there were only 9 cases of umbilical artery samples and 8 cases of umbilical vein samples were collected. Only 3 cases collected both Pua and Puv blood samples at the same time (see serial paper II). PuaO2 in gradually decreased with time (heartbeat frequency), until Pua contracted after spontaneous breathing produced about 8~10 heartbeats, and then could not get enough blood samples. Only 3 newborns were able to take blood samples after spontaneous breathing for 8~10 heartbeats, and their PuaO2 were jumped to 186.0, 137.0 and 93.8 mmHg respectively. The mean value of PuaO2 was (25.94±6.79, 18.04~37.51)mmHg, the highest value was (29.11±6.46, 23.00~45.90)mmHg, and the lowest value was (21.34±5.54, 14.00~33.60)mmHg. Although PuvO2 decreased gradually with time (heartbeat) too, most of them also showed the tendency of alternately rising and falling with the regularity of mother's respiration. The mean value of PuvO2 was (53.35±21.35, 32.56~100.73)mmHg, the highest value was (90.38±48.44, 43.40~153.00)mmHg, and the lowest value was (36.96±14.90, 24.80~73.80)mmHg. Although there were large individual differences, the mean, highest and lowest values of PuvO2 were significantly higher than those of PuaO2 (P<0.05); although PuvCO2 slightly lower than PuaCO2, it was no significant difference (P>0.05). Conclusion: PuaO2 decreases gradually with time before spontaneous breathing after the delivered fetus as a newborn, and it induces the first inhalation to start spontaneous breathing when it reaches the threshold of triggering breathing.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: The objective is to find the characteristics of arterial blood sample waveform in different respiration models. Methods: Six post-operative patients with normal heart function and negative Allen test, were 4 male and 2 female, (59.00±16.64)year, (71.67±0.37)kg, left ventricular ejection fraction(LVEF) (61.33±2.16)%, had been placed the arterial catheterization and central venous catheterization for continuous collecting arterial in 3 different kinds of respiration models: normal breathing, no breathing and deep breathing. We selected two breaths cycles of waveform from each patient for data calculations of magnitudes and time interval. Compare the adjacent highest and lowest values of patients to verify whether there are periodic wave-like signal changes in arterial and venous blood gas in the three breathing states. In addition, statistical t-test analysis was performed on the change amplitude of the periodic wave-like signal of the patient's arterial and venous blood gas to compare whether there is a difference. Results: The heart beat numbers for drawing blood into pipe were 15-16, and all covered more than 2 breathing cycles. There were significant changes of arterial PaO2 (i.e. the highest high values compare to the next lowest values, P<0.05) in three different breathing models(normal, no breathing and high breathing), the magnitudes of which were (9.96±5.18)mmHg, (5.33±1.55)mmHg and (13.13±7.55)mmHg, with (8.09±2.43)%, (5.29±2.19)% and (10.40±2.68)% from their mean respectively. PO2 in venous blood gas did not show wavy changes under normal breathing, 20 s breath holding and high tidal volume ventilation. The amplitudes were (1.63 ± 0.41) mmHg, (1.13 ± 0.41) mmHg and (1.31 ± 0.67) mmHg, which were (3.91 ± 1.22)%, (2.92 ± 1.12)%, (3.33 ± 1.81)%, respectively, which were significantly lower than that of arterial blood gas under the same state, but there was no significant difference between groups. Conclusion: With continuous beat-by-beat arterial blood sampling and ABG analyzing method in three different breathing models, We obtain a clear evidence of the biggest periodic parameters ABG waveform in high breathing models, which followed by normal breathing models, no breathing was the smallest, and the wave variation amplitude of venous oxygen partial pressure was not obvious in the three respiratory states, which implies the oscillatory information of the arterial blood with comes from the gas exchanging in the lung.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: The arterial blood with the oscillatory information comes from the right heart system after gas exchanging in the lung. However, the evidence of the waveform of venous ABG is lack. The objectives of this article are to compare the different information between arterial and venous beat-by-beat blood sample at the same time. Methods: Six post-operative patients with normal heart function and negative Allen test, had been placed the arterial catheterization and central venous catheterization directly connected to pre-heparin plasticpipes for continuous collecting arterial and venous blood. We twisted the 2 pipes into helix formation. After drawing arterial and venous blood with syringes in one heart beat with one helix at the same time, totally 15 heart beats, clipping the pipes with forceps, we put the helix pipe into icedwater at once and analyses PaO2, PaCO2, pH and SaO2 as soon as possible. We selected two breathscycles of waveform from each patient for data calculations of magnitudes and time interval. Results: The heart beat numbers for drawing blood into pipe were 15~16, and all covered more than 2 breathing cycles. There were significant changes of arterial PaO2(i.e. the highest high values compare to the next lowestvalues, P<0.05), but no significant changes in venous blood(P>0.05). The magnitudes of changing PaO2 in arterial and venous blood sample were (9.96±5.18)mmHg and (1.63±0.41)mmHg with significant variance(P=0.010), and they were (8.09±2.43)% and (3.91±1.22)%from their mean with significant variance(P=0.009) respectively. Conclusion: With continuous beat-by-beat arterial and venous blood sampling and ABG analyzing method at the same time, we obtain a clear evidence of periodic parameters ABG waveform, which following breathing cycle, but no clear ABG waveform of the periodic parameters in the venous blood samples, which implies the oscillatory information of the arterial blood with comes from the gas exchanging in the lung.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
OBJECTIVE:To assess the cardiopulmonary exercise testing (CPET) derived performance of oxygen uptake and ventilation efficiency parameters, including oxygen uptake efficiency plateau (OUEP) , oxygen uptake efficiency slope (OUES), V·E/V·CO2 slope and lowest V·E/V·CO2, in patients with end-stage chronic heart failure (CHF) and evaluate their clinical value on monitoring cardiac function and hemodynamic status.METHODS:A total of 26 end-stage CHF patients considered for heart transplantation were enrolled in this study. CPET, echocardiography and invasive hemodynamic examinations with Swan-Ganz flowing balloon catheter were performed. Correlation analysis was made between oxygen uptake and ventilation efficiency parameters from CPET and echocardiographic and hemodynamic parameters.RESULTS:OUEP and OUES showed good correlation with peak oxygen consumption (peak V·O2) (r = 0.535, P < 0.01;r = 0.840, P < 0.001). In end-stage CHF patients, the slope of OUEP with respect to peak V·O2 is about 32, but the slope of OUES with respect to peak V·O2 is only about 2. The difference was 16 times. The change of OUEP was more sensitive and significant than those of OUES and peak V·O2 (P < 0.05). OUEP, peak V·O2 (%pred), V·E/V·CO2 slope and lowest V·E/V·CO2 were all correlated well with non-invasive hemodynamic parameters peak cardiac output (r = 0.535, P < 0.01; r = 0.652, P < 0.001; r = -0.640, P < 0.001; r = -0.606, P = 0.001 respectively) and peak cardiac index (r = 0.556, P < 0.01;r = 0.772, P < 0.001; r = -0.641, P < 0.001; r = -0.620, P < 0.001 respectively) derived from CPET, but not correlated with invasive hemodynamic parameters cardiac output and cardiac index at rest (P > 0.05). Both peak V·O2 (%pred) and V·E/V·CO2 slope were significantly correlated with invasive hemodynamic parameters systolic pulmonary arterial pressure (r = -0.424, P < 0.05; r = 0.509, P < 0.01) and mean pulmonary arterial pressure (r = -0.479, P < 0.05; r = 0.405, P < 0.05). Peak V·O2 (%pred) was also significantly correlated with pulmonary capillary wedge pressure (r = -0.415, P < 0.05), and V·E/V·CO2 slope was significantly correlated with pulmonary vascular resistance (r = 0.429, P < 0.05).CONCLUSIONS:The oxygen uptake and ventilation efficiency parameters derived from CPET, including peak V·O2, OUEP, lowest V·E/V·CO2 and V·E/V·CO2 slope etc, are objectively monitoring and evaluating cardiac function and hemodynamic status. And they are useful for optimizing clinical management of patients with end-stage CHF.
Zhonghua xin xue guan bing za zhi 2015
BACKGROUND:Decline in oxygen uptake efficiency (OUE), especially during exercise, is found in patients with chronic heart failure. In this study we aimed to test the validity and usefulness of OUE in evaluating gas exchange abnormality of patients with idiopathic pulmonary arterial hypertension (IPAH).METHODS:We retrospectively investigated the cardiopulmonary exercise test (CPET) with gas exchange measurements in 32 patients with confirmed IPAH. All patients also had resting hemodynamic measurements and pulmonary function test (PFT). Sixteen healthy subjects, matched by age, sex, and body size were used as controls, also had CPET and PFT measurements.RESULTS:In IPAH patients, the magnitude of absolute and percentage of predicted (%pred) oxygen uptake efficiency slope (OUES) and oxygen uptake efficiency plateau (OUEP), as well as several other CPET parameters, were strikingly worse than healthy subjects (P<0.0001). Pattern of changes in OUE in patients is similar to that in controls, In IPAH patients, OUE values at rest, warming up, anaerobic threshold and peak exercise were all significantly lower than in normal (P<0.0001). OUEP%pred, better than OUES%pred, correlated significantly with New York Heart Association (NYHA) functional Class (r = -0.724, P<0.005), Total Pulmonary Vascular Resistance (TPVR) (r = -0.694, P<0.005), diffusing capacity for carbon monoxide (DLCO) (r = 0.577, P<0.05), and the lowest ventilation versus CO2 output ratio during exercise (LowestV˙E/V˙CO2) (r = -0.902, P<0.0001). In addition, the coefficient of variation (COV) of OUEP was lower (20.9%) markedly than OUES (34.3%) (P<0.0001).CONCLUSIONS:In patients with IPAH, OUES and OUEP are both significantly lower than the healthy subjects. OUEP is a better physiological parameter than OUES in evaluating the gas exchange abnormality of patients with IPAH.
PloS one 2014
OBJECTIVE:To observe oxygen uptake efficiency plateau (OUEP, i.e.highest V˙O2/V˙E) and carbon dioxide output efficiency (lowest V˙E/V˙CO2) parameter changes during exercise in normal subjects.METHODS:Five healthy volunteers performed the symptom limited maximal cardiopulmonary exercise test (CPET) at Harbor-UCLA Medical Center. V˙O2/V˙E and V˙E/V˙CO2 were determined by both arterial and central venous catheters. After blood gas analysis of arterial and venous sampling at the last 30 seconds of every exercise stage and every minute of incremental loading, the continuous parameter changes of hemodynamics, pulmonary ventilation were monitored and oxygen uptake ventilatory efficiency (V˙O2/V˙E and V˙E/V˙CO2) was calculated.RESULTS:During CPET, as the loading gradually increased, cardiac output, heart rate, mixed venous oxygen saturation, arteriovenous oxygen difference, minute ventilation, minute alveolar ventilation, tidal volume, alveolar ventilation and pulmonary ventilation perfusion ratio increased near-linearly (P < 0.05-0.01, vs.resting); arterial oxygen concentration maintained at a high level without significant change (P > 0.05); stroke volume, respiratory rate, arterial partial pressure of carbon dioxide, arterial blood hydrogen ion concentration and dead space ventilation ratio significantly changed none-linearly (compare resting state P < 0.05-0.01).OUE during exercise increased from 30.9 ± 3.3 at resting state to the highest plateau 46.0 ± 4.7 (P < 0.05 vs.resting state), then, declined gradually after anaerobic threshold (P < 0.05-0.01, vs.OUEP) and reached 36.6 ± 4.4 at peak exercise. The V˙E/V˙CO2 during exercise decreased from the resting state (39.2 ± 6.5) to the minimum value (24.2 ± 2.4) after AT for a few minutes (P > 0.05 vs.earlier stage), then gradually increased after the ventilatory compensation point (P < 0.05 vs.earlier stage) and reached to 25.9 ± 2.7 at peak exercise.CONCLUSIONS:Cardiac and lung function as well as metabolism change during CPET is synchronous.In the absence of pulmonary limit, appearing before and after anaerobic threshold, OUEP and lowest V˙E/V˙CO2 could be used as reliable parameters representing the circulatory function.
Zhonghua xin xue guan bing za zhi 2014