BACKGROUND:The tissue response viewer (TRV) is a multiparametric index that incorporates time, power, tissue pressure, impedance, and wall thickness data during radiofrequency catheter ablation (RFCA) and is used to predict the transmurality of lesions. This study aimed to evaluate the feasibility and accuracy of the TRV in a porcine model.METHODS:Twelve pigs underwent preablation high-density voltage and activation mapping of two atria, and both were repeated after linear RFCA. Intentional gaps were kept in the left atrium (LA) and were touched up in the right atrium (RA). Standard and high powers were, respectively, performed in the LA ablation. Six pigs were immediately sacrificed for pathological examination after the mapping and ablation procedure (acute study). Another six pigs were kept for 4 weeks before remapping and pathological examination (chronic study).RESULTS:All animals completed the planned procedure. The TRV function showed a sensitivity of 97.1% and a specificity of 76.9% in the acute study, and a sensitivity of 95.9% and a specificity of 72.5% in the chronic study to predict the transmural lesion. All positive and negative predictive values were over 80%. In addition, the TRV achieved higher sensitivity (92.3% vs. 85.0%) and specificity (88.2% vs. 78.9%) to predict the transmural lesion in LA ablation with high power compared with standard ablation.CONCLUSIONS:This study presents the histopathological validation of TRV to predict transmural lesions. The use of TRV may guide a more individual ablation and a more precise touch-up of gaps for atrial arrhythmias.
Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese 2023
Inadequate R wave amplitude (RWA) after implantable cardiac defibrillator (ICD) implantation in patients with arrhythmogenic cardiomyopathy (ACM) was suspected to relate to right ventricle impairment. However, little data-based evidence was provided to quantify the association. We retrospectively enrolled ACM patients receiving CMR examinations before transvenous ICD implantation from Fuwai Hospital. The RWA was obtained within 24 h and at 2-6-month follow-up after the operation. Structural, functional, as well as tissue characterization of the left ventricle (LV) and right ventricle (RV), were analyzed in relation to RWA. Among the 87 ACM patients (median RWA: 8.0 mV), 19 (21.8%) patients were found with low initial RWA (<5 mV) despite attempts in multiple positions. RV end diastolic diameter (RVEDD), (r = -0.44), RV ejection fraction (RVEF, r = 0.43), RV end diastolic volume index (RVEDVi, r = -0.49), RV end systolic volume index (RVESVi, r = -0.53), RV global circumferential (RVGCS, r = -0.64), and radial strain (RVGRS, r = 0.61, all p < 0.001) rather than LV metrics correlated strongly with initial RWA. RVGCS, RVESVi, and RVGRS were decent predictors of low RWA (areas under the curve AUC: 0.814, 0.769, 0.757, respectively) early after implantation and during 2-6-month follow-up. To summarize, low RWA of ICD lead in ACM patients was associated with RV abnormalities. The RVGCS, RVGRS, and RVESVi can be valuable predictors for identifying low RWA prior to ICD implantation.
Journal of clinical medicine 2023
BACKGROUND & OBJECTIVE:Despite the burden of sudden cardiac arrest (SCA) worldwide, implantable cardioverter-defibrillators (ICDs) are underutilized, particularly in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA trial demonstrated that primary prevention (PP) patients in these regions benefit from an ICD or a cardiac resynchronization therapy defibrillator (CRT-D). We aimed to compare the rate of device therapy and mortality among ischemic and non-ischemic cardiomyopathy (ICM and NICM) PP patients who met guideline indications for ICD therapy and had an ICD/CRT-D implanted.METHODS:Improve SCA was a prospective, non-randomized, non-blinded multicenter trial that enrolled patients from the above-mentioned regions. All-cause mortality and device therapy were examined by cardiomyopathy (ICM vs NICM) and implantation status. Cox proportional hazards methods were used, adjusting for factors affecting mortality risk.RESULTS:Of 1848 PP NICM patients, 1007 (54.5%) received ICD/CRT-D, while 303 of 581 (52.1%) PP ICM patients received an ICD/CRT-D. The all-cause mortality rate at 3 years for NICM patients with and without an ICD/CRT-D was 13.1% and 18.3%, respectively (HR 0.51, 95% CI 0.38-0.68, p < 0.001). Similarly, all-cause mortality at 3 years in ICM patients was 13.8% in those with a device and 19.9% in those without an ICD/CRT-D (HR 0.54, 95% CI 0.33-.0.88, p = 0.011). The time to first device therapy, time to first shock, and time to first antitachycardia pacing (ATP) therapy were not significantly different between groups (p ≥ 0.263).CONCLUSIONS:In this large data set of patients with a guideline-based PP ICD indication, defibrillator device implantation conferred a significant mortality benefit in both NICM and ICM patients. The rate of appropriate device therapy was also similar in both groups.CLINICAL TRIAL REGISTRATION:ClinicalTrials.gov ID: NCT02099721.
Indian heart journal 2023
Atrial high-rate episodes (AHREs) are prevalent in approximately 1/3 of patients with cardiac implanted electronic devices and are associated with an increased risk of several adverse outcomes. This study aimed to explore the factors associated with AHRE progression and the risk of all-cause mortality. At least 1 day with AHRE burden ≥15 minutes was identified in 124 of 343 recipients (36.2%) of an implantable cardioverter defibrillator or cardiac resynchronization therapy device. We included patients whose AHRE burden at the time of first detection was ≥15 minutes but <24 hours (n = 107). Various cut-off values (15 minutes, 6 hours, and 24 hours) of daily AHRE burden were analyzed. During an average follow-up of 4.2 years, 60 patients (56.1%) experienced ≥1 progression to greater AHRE burden. Patients with hypertension or greater AHRE burden at first detection were associated with faster progression. In addition, 27 deaths (45%) occurred among 60 patients with AHRE progression, compared with 25.5% (12 of 47) for those without progression. After multivariable adjustment, AHRE progression was independently associated with all-cause mortality (hazard ratio 2.56, 95% confidence interval 1.23 to 5.35, p = 0.012). Notably, AHRE progression within 1 month after their first detection was associated with an increased risk for all-cause mortality (hazard ratio 4.01, 95% confidence interval 1.76 to 9.16, p = 0.001) compared with patients without progression. However, a similar risk was not observed among patients with AHRE progression occurring after 1 month after their first detection. In conclusion, >1/2 of the patients with AHRE progressed to a greater burden over time. Continuous monitoring of the AHRE burden may help identify patients at great risk for death.
The American journal of cardiology 2023
Background:Implantable cardioverter-defibrillator (ICD) implantation is a key therapeutic option in arrhythmogenic right ventricular cardiomyopathy (ARVC) to prevent sudden cardiac death due to ventricular tachycardia (VT) and fibrillation (VF). However, sub-optimized R-wave sensing due to myocardium loss interferes with VT/VF identification and appropriate therapy. We tried to implant a 3830 lead to the left ventricular septum (LVS) to facilitate ICD sensing in an ARVC patient.Case summary:A 68-year-old woman diagnosed with ARVC was scheduled to undergo ICD implantation. Initially, no sites with suitable R-wave amplitudes were found in the right ventricle (RV) to deploy the defibrillation lead (<3.0 mV). It was likely due to severe RV involvement, but the LVS myocardium was more preserved based on cardiac magnetic resonance imaging. Therefore, we implanted a 3830 lead into the deep area of the septum to facilitate R-wave sensing. During the procedure from the right to left septum, the R-wave amplitude significantly increased (2.6 to 4.3-7.1 mV). Left ventricular septum pacing was finally achieved with favourable R-wave sensing (9.9 mV 24 h post-operation). The 3830 lead was plugged into the IS-1 port, while the defibrillation lead was plugged into the DF-1 port. After a 4-month follow-up, the R-wave amplitude of the 3830 lead was 11.1 mV.Discussion:When the R-wave sensing is not acceptable for ICD implantation in ARVC patients, it is critical to assess myocardial conditions comprehensively. If the septal myocardium is preserved, implanting a 3830 lead to the deep or LVS is feasible to improve R-wave sensing.
European heart journal. Case reports 2023
Introduction: Autonomic nervous system (ANS) function quantified by heart rate variability (HRV) was associated with long-term prognosis, but it was rarely used in the evaluation of patients with heart failure, especially those with cardiac resynchronization therapy-defibrillator (CRT-D) implantation. This study aimed to describe the changes in ANS function among patients who underwent CRT-D with remote home monitoring function, and explore predictive value of HRV for ventricular tachyarrhythmias (VTAs) and all-cause mortality. Method: Patients who underwent CRT-D implantation were included. Device-measured all-day HR, night-time HR, and HRV (measured by the standard deviation of the atrial-atrial sensed intervals) were used to quantify ANS function. Multivariate Cox proportional hazards models were fitted to calculate hazard ratios (HRs) and 95% confidence intervals (CIs) of VTAs or all-cause mortality in relation to ANS function at baseline and 6 months post-implantation. The cutoff value was determined using restrictive cubic splines. Multivariable logistic regression was further established to determine factors influencing postoperative HRV. Results: A total of 170 patients treated with CRT-D were eligible for analysis. During a median follow-up period of 50.8 months, 61 patients died and 69 patients experienced at least one spontaneous episode of VTAs. At 6 months after CRT implantation, 114 patients showed improvement in HRV, increasing from 66.4 ± 19.4 ms to 76.7 ± 21.2 ms. The postoperative HRV was associated with both all-cause mortality (HRs: 0.983; 95% CI: 0.968 to 0.998, p = 0.012) and VTAs (HRs: 0.973; 95% CI: 0.954 to 0.993, p = 0.008), and the relative risk would significantly increase when the postoperative HRV lower than 75 ms. After adjusting for basic ANS function and possible influencing factors, patients without diabetes (p = 0.018) and with higher daily physical activity (p = 0.041) could maintain higher postoperative HRV after CRT implantation. Conclusion: More than two-thirds of heart failure patients showed improvement in ANS function following CRT treatment. However, patients with diabetes and low daily physical activity levels have difficulty maintaining a higher postoperative HRV, which is associated with a worse clinical outcome.
Frontiers in physiology 2023
BACKGROUND:Device-detected atrial high-rate episodes (AHREs) were associated with an increased thromboembolic risk. Although limited data regarding the long-term prognosis of patients with AHRE were controversial, this study aimed to identify the association of device-detected AHRE with mortality.METHODS:This observational study included patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) placement and no history of atrial fibrillation (AF), atrial flutter (AFL), or atrial tachycardia (AT). During follow-up, patients with at least 1 day of AHRE duration ≥ 15 minutes were identified. The primary endpoint was cardiovascular mortality, and the secondary endpoint was all-cause mortality.RESULTS:During a mean follow-up period of 4.2 years, AHREs were detected in 124 of 343 (36.2%) patients. Of these, 44 deaths (35.5%) occurred in 124 patients with AHREs, which was significantly higher than those without AHREs (43 of 219; 19.6%; P = 0.001). The multivariate analysis revealed that patients with AHRE had a significantly higher risk of cardiovascular (hazard ratio [HR], 2.40; 95% confidence interval [CI], 1.23-4.67; P = 0.010), and all-cause mortality (HR, 2.31; 95% CI, 1.49-3.59; P < 0.001). Further analysis indicated that this association remained significant in patients with higher burden (≥ 6 hours) but not in patients with lower burden (≥ 15 minutes to 6 hours). Notably, even after excluding the patients diagnosed with clinical AF during follow-up, the remaining patients with AHREs still exhibited a higher risk of cardiovascular and all-cause mortality compared with patients without AHREs.CONCLUSIONS:AHREs were prevalent in ICD or CRT-D recipients with no history of clinical AF, AFL, or AT and were associated with more than twice the risk of cardiovascular and all-cause mortality.CLINICAL TRIAL REGISTRATION:No. ChiCTR-ONRC-13003695.
The Canadian journal of cardiology 2023
Objectives:This study aims to investigate the association between waist circumference (WC) and cardiovascular death in patients with permanent pacemakers (PPMs).Methods:This is a retrospective cohort study that enrolled patients who underwent PPM implantation in Fuwai Hospital from May 2010 to April 2014, according to the BIOTRONIK Home Monitoring database. The WC was treated as sex-specific quartiles, and patients were divided into three groups according to body mass index (BMI): normal (≤22.9 kg/m2), overweight (23-24.9 kg/m2), and obese (≥25 kg/m2). Cox proportional hazards models were used to calculate hazard ratios and 95% confidence intervals for cardiovascular death according to WC and BMI in patients.Results:492 patients with PPMs implantation were analyzed (mean age: 71.9 ± 10.8 years; 55.1% men (n = 271)). Data showed that after a mean follow-up 67.2 ± 17.5 months, 24 (4.9%) patients had experienced cardiovascular death and 71 (14.4%) were cases of all-cause mortality. Men in the third quartile of WC had an HR of 10.67 (Model 4, 95% CI: 1.00-115.21, p trend = 0.04) for cardiovascular death. However, the association disappeared in female patients (Model 4, HR = 3.99, 95% CI: 0.37-42.87, p trend = 0.25). There was no association between BMI and cardiovascular death or all-cause mortality in both male and female patients.Conclusions:Abdominal obesity was associated with an increased risk of cardiovascular death in patients with PPMs, and this relationship was only in male patients.
Evidence-based complementary and alternative medicine : eCAM 2023
Importance:Stroke is the leading cause of death in China. However, recent data about the up-to-date stroke burden in China are limited.Objective:To investigate the urban-rural disparity of stroke burden in the Chinese adult population, including prevalence, incidence, and mortality rate, and disparities between urban and rural populations.Design, Setting, and Participants:This cross-sectional study was based on a nationally representative survey that included 676 394 participants aged 40 years and older. It was conducted from July 2020 to December 2020 in 31 provinces in mainland China.Main Outcomes and Measures:Primary outcome was self-reported stroke verified by trained neurologists during a face-to-face interviews using a standardized protocol. Stroke incidence were assessed by defining first-ever strokes that occurred during 1 year preceding the survey. Strokes causing death that occurred during the 1 year preceding the survey were considered as death cases.Results:The study included 676 394 Chinese adults (395 122 [58.4%] females; mean [SD] age, 59.7 [11.0] years). In 2020, the weighted prevalence, incidence, and mortality rates of stroke in China were 2.6% (95% CI, 2.6%-2.6%), 505.2 (95% CI, 488.5-522.0) per 100 000 person-years, and 343.4 (95% CI, 329.6-357.2) per 100 000 person-years, respectively. It was estimated that among the Chinese population aged 40 years and older in 2020, there were 3.4 (95% CI, 3.3-3.6) million incident cases of stroke, 17.8 (95% CI, 17.5-18.0) million prevalent cases of stroke, and 2.3 (95% CI, 2.2-2.4) million deaths from stroke. Ischemic stroke constituted 15.5 (95% CI, 15.2-15.6) million (86.8%) of all incident strokes in 2020, while intracerebral hemorrhage constituted 2.1 (95% CI, 2.1-2.1) million (11.9%) and subarachnoid hemorrhage constituted 0.2 (95% CI, 0.2-0.2) million (1.3%). The prevalence of stroke was higher in urban than in rural areas (2.7% [95% CI, 2.6%-2.7%] vs 2.5% [95% CI, 2.5%-2.6%]; P = .02), but the incidence rate (485.5 [95% CI, 462.8-508.3] vs 520.8 [95% CI, 496.3-545.2] per 100 000 person-years; P < .001) and mortality rate (309.9 [95% CI, 291.7-328.1] vs 369.7 [95% CI, 349.1-390.3] per 100 000 person-years; P < .001) were lower in urban areas than in rural areas. In 2020, the leading risk factor for stroke was hypertension (OR, 3.20 [95% CI, 3.09-3.32]).Conclusions and Relevance:In a large, nationally representative sample of adults aged 40 years or older, the estimated prevalence, incidence, and mortality rate of stroke in China in 2020 were 2.6%, 505.2 per 100 000 person-years, and 343.4 per 100 000 person-years, respectively, indicating the need for an improved stroke prevention strategy in the general Chinese population.
JAMA network open 2023
BACKGROUND:Although studies have shown that an increased resting heart rate measured randomly at a single point of the day has been associated with adverse cardiovascular outcomes, the utility of continuous monitoring of nighttime heart rate (NTHR) has remained largely uninvestigated.OBJECTIVE:This study aimed to explore the association between NTHR and cardiovascular mortality.METHODS:The Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device-implanted Patients, which is a prospective cohort study, enrolled patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator between 2010 and 2015. Baseline NTHR was measured during the programmed sleep period from 30 to 60 days after implantation. The primary outcome was cardiovascular mortality, fitted by a restricted cubic spline function.RESULTS:A total of 534 implantable cardioverter-defibrillator recipients with sinus rhythm during the detection window were included in the study. The mean baseline NTHR was 59.6 ± 8.0 beats/min. During the follow-up period of 60.4 ± 21.8 months, 88 (16.5%) patients experienced cardiovascular mortality. After considering potential confounders, a linear association was observed. Each 1 beat/min increase in NTHR was associated with a 7.8%, 10.1%, and 5.7% increase in the risk of cardiovascular mortality in the total population, patients with heart failure, and patients without heart failure, respectively.CONCLUSION:Continuous monitoring of NTHR may identify patients at high risk of cardiovascular mortality in a timely manner, with the potential for "preemptive" action.TRIAL REGISTRATION:No. ChiCTR-ONRC-13003695.
Heart rhythm 2023