罗斌

中国医学科学院阜外医院 心律失常中心

Ablation of ventricular arrhythmias with predominant monophasic "R" waves in precordial leads from the left sinus of Valsalva: Electrocardiographic and electrophysiologic characteristics.

BACKGROUND:While the left sinus of Valsalva (LSV) is a frequent origin of ventricular arrhythmias (VAs). Uncommonly, VAs with right bundle branch block (RBBB) morphology may be successfully terminated from the LSV.OBJECTIVE:We aimed to investigate the electrocardiographic and electrophysiologic characteristics of VAs with RBBB which were successfully eliminated from the LSV.METHODS:We identified patients with VAs successfully ablated from the LSV from January 2014 to December 2017 and compared electrophysiologic characteristics and ablation sites of those VAs with RBBB versus a control group of patients with left bundle branch block morphology.RESULTS:We identified 18 patients with RBBB and predominant "R" waves in the precordial leads. In 12 (66.7%) patients, a small "s" wave in lead V2 and positive "R" in the remaining pericardial leads could be seen. Overall, a single "V" potential was seen in 72.2% of patients in the study group, while discrete potentials were recorded in 80% of the patients in the control group. The majority (88.9%) of the VAs could only be terminated at the nadir of the LSV in the study group. After mean follow-up of 33 ± 14 months, 93.8% and 92% were free of VAs after initial ablation in study and control group, respectively (P = 0.99).CONCLUSION:Some VAs with predominant monophasic "R" wave in precordial leads could be terminated from LSV, especially a small "s" wave in lead V2 was recorded. The nadir of LSV is highly successful for RBBB VAs and single electrogram was recorded at the target for most of the cases.

2.7
3区

Journal of cardiovascular electrophysiology 2019

Comparison of electrocardiogram characteristics and pacing parameters between left bundle branch pacing and right ventricular pacing in patients receiving pacemaker therapy.

AIMS:This study explores the feasibility of left bundle branch pacing (LBBP) and characterizes electrocardiogram (ECG) patterns during the pacing in comparison with conventional right ventricular pacing (RVP).METHODS AND RESULTS:Forty pacing-indicated patients were prospectively enrolled. Twenty patients underwent LBBP (the LBBP group), and 20 patients underwent RVP (the RVP group). Left bundle branch pacing was achieved by transseptal method in the basal ventricular septum. Electrocardiogram characteristics, pacing parameters, pacing sites, and safety events were assessed at implantation and 3-month follow-up. In the LBBP group, the pacing lead was successfully placed near the endocardium of the left side of the septum. Electrocardiogram pattern during LBBP showed right bundle branch conduction delay. Left bundle branch block (LBBB) in two patients was corrected by LBBP. Post-implantation 3D echocardiography confirmed the pacing location. In the RVP group, ECG showed LBBB pattern. The paced QRS duration was 111.85 ± 10.77 ms in LBBP group and 160.15 ± 15.04 ms in the RVP group (P < 0.001). Pacing thresholds (at implantation: 0.73 ± 0.20 V in the LBBP group and 0.61 ± 0.23 V in the RVP group) remained low and stable at 3-month follow-up. No adverse event was observed during 3-month follow-up.CONCLUSION:This study demonstrates the clinical feasibility of LBBP. Left bundle branch pacing that has a low pacing threshold and produces narrow ECG QRS duration may be a new pacing strategy for patients in need of ventricular pacing.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2019

Long-term outcome of cryoballoon ablation versus radiofrequency ablation for focal atrial tachycardias originating from the pulmonary veins.

PURPOSE:We aimed to investigate the characteristics of focal atrial tachycardias (ATs) arising from the pulmonary veins (PVs), as well as the safety and long-term efficacy of cryoballoon (CB) versus radiofrequency (RF) ablation in this population.METHODS:Eighty-three patients with ATs arising from PVs from a consecutive series of 487 patients who underwent CB and RF ablation were retrospectively reviewed. Patients who had a prior history of atrial fibrillation (AF) were excluded. The AT origin was confirmed during the conventional electrophysiological study and activation mapping. The ablation approach was at the discretion of the operators.RESULTS:Thirty-five patients were managed with focal ablation, 25 were ablated with unilateral PV isolation (PVI), and the remaining 23 were performed with CB ablation. All procedures were successfully ablated. There was no significant difference in procedure time between CB group and RF focal group (43.7 ± 11.8 min vs. 45.8 ± 11.2 min, P = 0.121), whereas the fluoroscopy time in CB group was longer than in RF PVI group (10.1 ± 2.5 min vs. 8.4 ± 2.8 min, P < 0.001). There was 1 recurrence in CB group, 4 recurrences of AT in RF focal group, and 2 recurrence in RF PVI group (P = 0.643). Repeat ablation was performed in 6 of 7 patients. Seventy-eight patients were available for long-term follow-up. At a mean of 5.4 ± 4.6-year follow-up, 77 of 78 patients were free from AT without antiarrhythmic medication after 1.1 ± 0.3 procedures. No patient had procedural complications and developed AF during the follow-up period.CONCLUSIONS:CB ablation is an effective and safe tool to treat ATs originating from the PVs. The ATs originating from the PVs represent an isolated clinical process and are not likely to be the forerunner of a more diffuse process leading to the development of PV AF.

1.8
4区

Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing 2019

"Crosstalk" technique: A comparison between two generations of cryoballoon catheter.

INTRODUCTION:The "Crosstalk" technique: if pulmonary vein isolation (PVI) of the superior one is not achieved due to a gap in the inferior part, it could be done during inferior vein cryoablation. This maneuver minimizes the total energy delivery time and number of lesions. We aimed to correlate the likelihood of crosstalk phenomenon with certain anatomic characteristics.METHODS:A total of 676 patients undergoing a first ablation procedure for paroxysmal or persistent atrial fibrillation (470 first-generation cryoballoon [CB] and 206 second-generation CB) between June 2014 and December 2016 were included.RESULTS:"Crosstalk" phenomenon occurred in 32 patients (18 first-generation CB, 14 second-generation CB). Compared to 54 control patients without crosstalk, the angle between left superior pulmonary vein (LSPV) and left atrial (LA) roof-plane, left pulmonary common ostia were significant parameters associated with crosstalk (odds ratio [OR] = 1.20, ±95% confidence interval [CI]: 1.11-1.31, P < 0.001; OR = 5.67, ±95% CI: 1.08-28.69, P = 0.04). As for angle between LSPV and LA roof-plane, the cut-off value was 28.68° with a sensitivity of 72.22%, a specificity of 81.25%, and an area under the receiver operating characteristic curve of 0.87 to predict the possibility of crosstalk technique application to get isolated in LSPV. Among the crosstalk group, there was no statistical difference between first-generation CB and second-generation CB in pulmonary anatomic characteristics.CONCLUSION:Crosstalk technique can be effective in patients with AF undergoing CB ablation using with both first and second-generation CBs. Anatomic characteristics predictive of crosstalk include a left common ostia and smaller angle between the LSPV and LA roof-plane.

1.8
4区

Pacing and clinical electrophysiology : PACE 2018

Electrocardiographic and electrophysiologic differentiation between atriofascicular, long atrioventricular, and short atrioventricular decrementally conducting accessory pathways.

Aims:We aimed to examine the electrocardiographic and electrophysiologic characteristics of anterograde-conducting decremental accessory pathways (DAP) and to identify surrogate criteria to distinguish short atrioventricular (SAV) DAP from atriofascicular (AF) AP and long atrioventricular (LAV) DAP.Methods and results:We identified all patients with DAPs and analysed electrocardiographic and electrophysiologic characteristics. Distal insertion sites were examined using existing criteria, including V-H interval, ventricular activation at the right ventricular apex, and around tricuspid annulus during antidromic atrioventricular re-entrant tachycardia (A-AVRT) or complete pre-excitation and evaluated the AV node-like properties according to the response to adenosine and radiofrequency ablation. Out of 45 patients with DAPs, 28 (62.2%) had SAV-DAP (13 with definite AF-AP, 2 with definite LAV-DAP, 2 indeterminate). In all, 50% of SAV-DAPs and 53.3% of AF-AP/LAV-DAPs had 'rS' pattern in lead III. Longer QRS duration (159.9 ± 17.4 ms vs. 139.2 ± 14.3 ms, P < 0.0001) during full pre-excitation or A-AVRT differentiated SAV-DAP from AF-AP. The QRS-V(His) interval was longer for those with SAV-DAP compared vs. AF-AP/LAV-DAP (45.3 ± 2.4 ms vs. 22.9 ± 2.5 ms, P < 0.0001) and a cut-off value of 33.0 ms differentiated the two (sensitivity 81.3%, specificity 87.5%).Conclusion:The majority of the SAV-DAPs are located at the TA free wall. An 'rS' pattern in lead III is frequently seen in SAV-DAP as well as AF-AP/LAV-DAPs. Measuring the QRS-V(His) interval would be helpful to distinguish SAV-DAP from AF-AP/LAV-DAP.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2018

Right atrial dual-loop reentrant tachycardia after cardiac surgery: Prevalence, electrophysiological characteristics, and ablation outcomes.

BACKGROUND:Right atrial (RA) dual-loop reentrant tachycardia has been described in patients who have undergone open heart surgery. However, the prevalence, electrophysiological (EP) substrate, and ablation outcomes have been poorly characterized.OBJECTIVE:The purpose of this study was to investigate the prevalence, EP substrate, and ablation outcomes for RA dual-loop reentrant tachycardia after cardiac surgery.METHODS:We identified all patients with atrial tachycardia (AT) after cardiac surgery. We compared EP findings and outcomes of those with RA dual-loop reentrant tachycardia to a control group of patients with RA macroreentrant arrhythmias in the setting of linear RA free-wall (FW) scar.RESULTS:Of the 127 patients with 152 postsurgical ATs, 28 of the ATs (18.4%) had RA dual-loop reentry and 24 of 28 (85.7%) had tricuspid annular reentry combined with FW incisional reentry. An incision length >51.5 mm along the FW predicted the substrate for a second loop. In 22 of 23 patients (95.7%) with initial ablation in the cavotricuspid isthmus, a change in the interval between Halod to CSp could be recorded, and 15 of 23 patients (65.2%) had coronary sinus activation pattern change. Complete success was achieved in 25 of 28 patients (89.3%) in the dual-loop reentry group and in 64 of 69 patients (92.8%) in the control group. After mean follow-up of 33.9 ± 24.2 months, 24 of 28 patients (85.7%) and 60 of 69 patients (86.95%) were free of arrhythmias after the initial procedure in the 2 groups, respectively.CONCLUSION:The prevalence of RA dual-loop reentry is 18.4% of ATs with prior atriotomy scar. A long incision should alert physicians to the possibility of a second loop at the FW. Halo and coronary sinus activation patterns provide important clues to circuit transformation.

5.5
2区

Heart rhythm 2018

Clinical, electrocardiographic, and electrophysiological characteristics of left upper septal fascicular ventricular tachycardia.

Aims:We sought to investigate the clinical, electrocardiographic, and electrophysiological characteristics of left upper septal fascicular ventricular tachycardia (LUS-VT).Methods and results:Eleven consecutive patients with LUS-VT were identified among 196 patients with left fascicular ventricular tachycardia (VT). Clinical VTs presented as paroxysmal in 8 patients and incessant in 3 patients. Six patients had previous left posterior fascicular VT ablation history. All VTs had narrow QRS complexes with QRS duration of 101.1 ± 9.2 ms. The frontal QRS axis was normal or right deviation. Precordial morphology was either right bundle branch block type or similar to that of sinus rhythm. A retrograde His with H-V interval of 21.9 ± 7.2 ms was recorded during VT. The earliest Purkinje potential (PP) to QRS interval during VT averaged 35.7 ± 4.5 ms. Clear diastolic potentials (DPs) with high frequency and low amplitude were found in only one patient. Ten patients were managed successfully by 11 ablation sessions, and 1 patient declined ablation. Successful targets at the left upper septum were sites with the earliest PP (9 cases) or with DP (1 case) during VT. After ablation, 2 cases (10%) developed new left anterior hemiblock or incomplete left bundle branch block. No VT recurred during a median follow-up period of 3.2 (range 1.0-12.7) years.Conclusion:LUS-VT presented as narrow QRS complex tachycardia. Some LUS-VTs occurred after ablation targeting left posterior fascicular VT. The VTs can be managed successfully by focal ablation at the left upper septum with a mild risk of fascicular injury.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2018

Pulmonary vein isolation with real-time pulmonary vein potential recording using second-generation cryoballoon: Procedural and biophysical predictors of acute pulmonary vein reconnection.

OBJECTIVE:The study sought to evaluate the procedural and biophysical factors related to acute pulmonary vein isolation (PVI) guided by real-time pulmonary vein (PV) potential recordings.METHODS:A total of 180 consecutive patients with drug-resistant atrial fibrillation (AF) undergoing CB2 (second-generation version of cryoballoon) ablation were enrolled. Real-time monitoring of PV potentials was obtained using an inner lumen spiral mapping catheter.RESULTS:Acute isolation was achieved in all PVs without touch-up ablation. Real-time assessment of PV disconnection was possible in 611 of 711 (85.9%) PVs. A total of 617 (86.8%) PVs were isolated during the initial freeze. Longer time cycle integration (TCI) (TTI * freeze cycle, TCI) (254.6 ± 112.8 seconds vs 74.1 ± 59.7 seconds, P < 0.001), time to isolation (TTI) (94.3 ± 34.0 seconds vs 46.3 ± 26.2 seconds, P < 0.001), higher nadir temperature (-45.5 ± 5.3°C vs -50.4 ± 5.5°C, P < 0.001), longer time to -40°C (77.3 ± 22.7 seconds vs 55.7 ± 23.2 seconds, P < 0.001), faster interval rewarming time at 0°C (9.4 ± 4.3 seconds vs 12.4 ± 4.9 seconds, P = 0.008), and total balloon rewarming time (38.1 ± 11.6 seconds vs 47.7 ± 14.0 seconds, P = 0.003) were observed in PVs with acute reconduction. TTI ≤ 65 seconds predicted absence of acute reconnection with 84.2% sensitivity and 75.7% specificity, whereas TCI ≤ 119 seconds presented 94.7% sensitivity and 80.2% specificity. At a mean follow-up of 4.7 ± 1.4 months, 82.2% of patients were free of AF. None of those with PV reconnections suffered from AF recurrences.CONCLUSIONS:The ablation using CB2 is effective in achieving acute PVI. Real-time assessment of PVI could be achieved during CB application in 86% of PVs. The incidence of spontaneous PV reconnection is very low, observed in just 3% of isolated PVs. TTI ≤ 65 seconds and TCI ≤ 119 seconds predicted absence of acute PV reconnection. Although they may identify effective cryoapplications in the acute phase, their performance still needs to be verified in the long term.

1.8
4区

Pacing and clinical electrophysiology : PACE 2018

Predictors of hemoptysis in the setting of pulmonary vein isolation using the second-generation cryoballoon.

INTRODUCTION:To assess the predictors of hemoptysis using second-generation cryoballoon (CB).METHODS:Thirty patients with hemoptysis after second-generation CB ablation and 60 age-, gender-, and body mass index-matched controls were recruited. Anatomic parameters were obtained from preprocedural cardiac computed tomography (CT). Pulmonary vein isolation was performed with 28-mm balloon using single 3-minute freeze technique.RESULTS:Clinical and procedural characteristics were similar between the groups. A shorter distance between left superior PV (LSPV) and left main bronchus (LMB) was associated with hemoptysis (7.8 ± 4.3 mm vs. 12.5 ± 3.5 mm, P < 0.001), whereas no significant difference in the distance between right superior PV (RSPV) and right main bronchus (RMB) was found between groups (11.9 ± 3.5 mm vs. 12.9 ± 4.6 mm, P = 0.089). Additionally, the mean thickness of the connective tissue interposed between RSPV and RMB was significantly thicker than that between LSPV and LMB in both groups (both P < 0.001). A stepwise logistic multivariate analysis identified only the LMB-LSPV distance as an independent predictor of hemoptysis (odd ratio [OR] 2.676; 95% CI 1.121-4.843, P < 0.001). A cutoff value ≤ 9.5 mm predicted hemoptysis after CB ablation with 93.8% sensitivity and 75.0% specificity.CONCLUSION:Hemoptysis is a relatively rare event following second-generation CB ablation. The bronchi location obtained from CT aids in identifying high-risk population for the complication.

2.7
3区

Journal of cardiovascular electrophysiology 2018

Safety and efficacy of catheter ablation of ventricular arrhythmias with para-Hisian origin via a systematic direct approach from the aortic sinus cusp.

BACKGROUND:Catheter ablation of ventricular arrhythmias (VAs) originating from the para-Hisian region could be challenging because of a potential damage to atrioventricular conduction system.OBJECTIVE:The purpose of this study was to evaluate the safety and efficacy of catheter ablation of VAs originating from the para-Hisian region via a systematic direct approach from aortic sinus cusps (ASCs).METHODS:Twenty-one consecutive patients with VAs with para-Hisian origin were included. Electrophysiological mapping of the entire right ventricle was initially performed, and then retrograde ASC mapping was performed when the earliest ventricular activation was recorded in the His bundle region. Ablation was preferentially performed within ASCs in all patients.RESULTS:Radiofrequency energy delivery resulted in the elimination of VAs in 17 of 21 patients (81%). In the remaining 4 patients, radiofrequency application was initiated at the target site of the right ventricular septum around the His bundle region and clinical VAs were finally successfully eliminated without junctional rhythm in 2 of 4 patients. During a mean follow-up of 34.8 ± 11.3 months, 1 of the 19 acute successful patients had VA recurrence. No procedure-related complications occurred during ablation or follow-up.CONCLUSION:Catheter ablation of VAs originating from the para-Hisian region via a direct approach from ASCs may be safe and effective in most unselected patients.

5.5
2区

Heart rhythm 2018