王建德
中国医学科学院阜外医院 超声科
BACKGROUND:The anti-thrombotic strategy for patients with atrial fibrillation (AF) who have undergone percutaneous coronary intervention (PCI) for coronary artery disease (CAD) is a common and difficult challenge. This pilot study aimed to assess the feasibility and safety of "one-stop" left atrial appendage closure (LAAC) combined with PCI as an alternative stroke prophylaxis strategy.METHODS:From March 2017 to October 2019, AF patients with elevated bleeding risk and significant stable CAD requiring PCI were recruited to undergo LAAC as alternative stroke prophylaxis in Fuwai Hospital, Beijing, China. LAAC was performed either in the same setting with PCI (i.e. "one-stop" LAAC/PCI), or as staged procedure after PCI. Dual antiplatelet therapy was given for all patients after LAAC. Peri-procedural and intermediate-term clinical outcomes were assessed through hospital clinical records review and standardized telephone interviews.RESULTS:A total of 24 patients were recruited including 13 (54.2%) underwent stage procedure and 11 (45.8%) underwent "one-stop" procedure respectively. The mean CHA2DS2-VASc and HAS-BLED scores were 4.5±1.4 and 3 (IQR 3,4) respectively. Six patients (46.1%) in the staged procedure cohort were treated with triple anti-thrombotic following PCI, with 2 developed minor bleeding before LAAC. One patient ("one-stop" cohort) had gastrointestinal bleeding 1 day after procedure. Otherwise, there was no device related complication or peri-procedural stroke/myocardial infarction. After a mean 19±5.4 months follow-up, there was no death, myocardial infarction, stroke and systemic embolization detected.CONCLUSIONS:In this pilot study, "one-stop" LAAC with PCI was shown to be efficacious with no stroke, MI, VARC-2 major bleeding or CV death reported over a mean follow-up of 19 months, and safe with no major peri-procedural bleeding or device related complications.
American journal of cardiovascular disease 2021
BACKGROUND:The effective orifice area (EOA) is utilized to characterize the hemodynamic performance of the transcatheter heart valve (THV). However, there is no consensus on EOA measurement of self-expanding THV. We aimed to compare two echocardiographic methods for EOA measurement following transcatheter self-expanding aortic valve implantation.METHODS:EOA was calculated according to the continuity equation. Two methods were constructed. In Method 1 and Method 2, the left ventricular outflow tract diameter (LVOTd) was measured at the entry of the prosthesis (from trailing-to-leading edge) and proximal to the prosthetic valve leaflets (from trailing-to- leading edge), respectively. The velocity-time integral (VTI) of the LVOT (VTILVOT) was recorded by pulsed-wave Doppler (PW) from apical windows. The region of the PW sampling should match that of the LVOTd measurement with precise localization. The mean transvalvular pressure gradient (MG) and VTI of THV was measured by Continuous wave Doppler.RESULTS:A total of 113 consecutive patients were recruited. The mean age was 77.2 ± 5.5 years, and 72 patients (63.7%) were male. EOA1 with the use of Method 1 was larger than EOA2 (1.56 ± 0.39 cm2 vs. 1.48 ± 0.41 cm2, P = 0.001). MG correlated better with the indexed EOA1 (EOAI1) (r = -0.701, P < 0.001) than EOAI2 (r = -0.645, P < 0.001). According to EOAI (EOAI ≤ 0.65 cm2/m2, respectively), the proportion of sever prosthesis-patient mismatch with the use of EOA1 was lower than EOA2 (12.4% vs. 21.2%, P < 0.05). Compared with EOA2, EOA1 had lower interobserver and intra-observer variability (intra: 0.5% ± 17% vs. 3.8% ± 22%, P < 0.001; inter: 1.0% ± 9% vs. 3.5% ± 11%, P < 0.001).CONCLUSIONS:For transcatheter self-expanding valve EOA measurement, LVOTd should be measured in the entry of the prosthesis stent (from trailing-to-leading edge), and VTILVOT should match that of the LVOTd measurement with precise localization.
Journal of geriatric cardiology : JGC 2020
OBJECTIVES:To test whether multidetector computed tomography (MDCT) could completely replace transoesophageal echocardiography (TEE) to detect left atrial appendage (LAA) thrombi in atrial fibrillation (AF) patients using a large sample size.METHODS:783 patients with AF who underwent MDCT and TEE before catheter ablation were retrospectively included. Demographic data were obtained. Two radiologists blinded to clinical data made the imaging diagnosis.RESULTS:Most of the patients (96.2 %) had a CHA2DS2-VASc score (congestive heart failure, hypertension, age ≥ 75 years old (doubled), diabetes, stroke/transient ischaemic attack/thromboembolism (doubled), vascular disease, age 65-74 years, female sex) ≤ 3. Eight thrombi were identified by TEE, all of which were detected by MDCT; no thrombus was observed with TEE without the observation of filling defects by late-phase MDCT scanning in any of the patients. Using TEE as reference standard, the sensitivity, specificity, positive predictive value and negative predictive value of MDCT for thrombus detection were 100 %, 95.74 % (95 % CI 94.33 %-97.15 %), 19.51 % (95 % CI 16.73 %-22.29 %) and 100 %, respectively.CONCLUSIONS:For AF patients with low risk of stroke, when MDCT images showed no filling defect in the late phase, TEE prior to catheter ablation can be avoided.KEY POINTS:• MDCT can help detect the presence of LAA thrombus. • TEE can be avoided when late-phase MDCT shows no filling defect. • TEE is required in patients whose MDCT images indicate thrombus.
European radiology 2018
International journal of cardiology 2015