袁卫民
中国医学科学院阜外医院 实验外科
A miniature pig model of ischemic mitral regurgitation (IMR) was developed by posterior mitral chordae tendinae rupture and implantation of an ameroid constrictor. A 2.5-mm ameroid constrictor was placed around the left circumflex coronary artery (LCX) of male Tibetan miniature pigs to induce ischemia, while the posterior mitral chordae tendinae was also ruptured. X-ray coronary angiography, ECG analysis, echocardiography, and magnetic resonance imaging (MRI) were used to evaluate heart structure and function in pigs at baseline and one, two, four and eight weeks after the operation. Blood velocity of the mitral regurgitation was found to be between medium and high levels. Angiographic analyses revealed that the LCX closure was 10-20% at one week, 30-40% at two weeks and 90-100% at four weeks subsequent ameroid constrictor implantation. ECG analysis highlighted an increase in the diameter of the left atria (LA) at two weeks post-operation as well as ischemic changes in the left ventricle (LV) and LA wall at four weeks post-operation. Echocardiography and MRI further detected a gradual increase in LA and LV volumes from two weeks post-operation. LV end diastolic and systolic volumes as well as LA end diastolic and systolic volume were also significantly higher in pig hearts post-operation when compared to baseline. Pathological changes were observed in the heart, which included scar tissue in the ischemic central area of the LV. Transmission electron microscopy highlighted the presence of contraction bands and edema surrounding the ischemia area, including inflammatory cell infiltration within the ischemic area. We have developed a pig model of IMR using the posterior mitral chordae tendineae rupture technique and implantation of an ameroid constrictor. The pathological features of this pig IMR model were found to mimic the natural history and progression of IMR in patients.
PloS one 2014
OBJECTIVE:To study the relationship between inflammation and neointimal proliferation after coronary stent implantation in porcine model.METHODS:Twenty normal minipigs were randomly divided into group A (implanted with 316L bare metal stents), group B (implanted with 605L bare metal stents), group C (implanted with PLGA coating 605L stents), and group D (implanted with rapamycin-loaded PLGA coating 605L stents). Each minipig was implanted with two same stents in left anterior descending artery and right coronary artery. Four weeks later, the animals were sacrificed and histomorphometric measurements on the stent-segment coronary arteries were made to calculate the correlation between inflammation area and neointimal area.RESULTS:Group D had the smallest neointimal area [(0.64 +/- 0.38) mm2, P < 0. 001] and inflammation area (median 0.00 mm2, P = 0.009) among all the groups, while there were no statistical differences among group A, B, and C in neointimal area [(2.09 +/- 0.90), (2.11 +/- 1.07), and (1.42 +/- 0.35) mm2 respectively] and in inflammation area (0.22 , 0.21, and 0.09 mm2, respectively). Bivariate correlation analysis showed that the inflammation area was positively correlated with the neointimal area (P < 0.001, correlation coefficient = 0.719). When stent type, mean injury score, and EEL area were adjusted, partial correlations analysis showed that the inflammation area was still positively correlated with the neointimal area (P = 0.01, correlation coefficient = 0.498).CONCLUSION:Inflammation promotes the neointimal proliferation after coronary stent implantation. Sirolimus-eluting stent may reduce the inflammatory response.
Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae 2009
OBJECTIVE:The aim of this study was to identify the long-term character of the domestic bileaflet mechanical valve in the chronic implanted sheep model and to evaluate the potential value of the modal.METHODS:Six adult sheep underwent implanted mechanical bileaflet valve in pulmonary position under the cardio-pulmonary bypass with beating heart. The chronic implanted sheep model was built up and observed in the respects of a long-term survival, function of prosthesis and pathological specimen.RESULTS:Six adult sheep survived with good condition after operation. The average survival period of six sheep was (221 +/- 208) days. Two sheep were postoperatively sacrificed in 41 and 71 days, respectively. The necropsy revealed normal valve function without thrombosis, periprosthetic leakage and overgrowth of fibrous tissue. One sheep died from dysfunction of prosthetic valve at the postoperative 196 days. The reason was the prosthetic thrombosis with slight overgrowth of fibrous tissue in periprosthesis. The other two sheep died from severe anemia at the postoperative 196 days and 234 days, and the autopsy revealed no abnormal finding else. And one remained to survive with good condition up to now (over 617 days) and was checked by Doppler echocardiogram twice at the postoperative 438 days and 479 days, respectively. The results showed normal function of the bileaflet valve in pulmonary position.CONCLUSION:The long-term good effects would be achieved by using the implanted new domestic bileaflet valve in pulmonary position of sheep.
Zhonghua wai ke za zhi [Chinese journal of surgery] 2003