张大伟
中国医学科学院阜外医院 普外科
INTRODUCTION:Percutaneous patent ductus arteriosus (PDA) occlusion has become the preferred therapeutic option, which uses fluoroscopy as the guidance. To reduce the x-ray exposure, PDA occlusion using the Amplatzer Duct Occluder II (ADO II) under guidance of transthoracic echocardiography only was conducted. This single center study aims to access the safety and efficiency of this new strategy.METHODS AND RESULTS:From June 2013 to May 2015, 63 consecutive PDA patients underwent transthoracic echocardiography-guided PDA occlusion through the femoral artery. Outpatient follow-up was conducted at 1, 3, and 6 months, and yearly. Sixty-two patients successfully underwent echocardiography-guided percutaneous PDA occlusion. One patient was converted to minimally invasive transthoracic occlusion due to failure of delivery sheath passage through tortuous PDA. Mean procedure duration was 24.3 ± 7.0 minutes; ADO II diameter averaged 4.6 ± 0.9 mm; 8 cases showed traces of residual shunt immediately after operation which resolved after 24 hours; and mean hospital stay was 3.4 ± 0.5 days. There was no occluder migration, hemolysis, pericardial effusion, pulmonary branch or aortic stenosis at mean 13.5 ± 4.8 months follow-up.CONCLUSIONS:This study demonstrated that percutaneous PDA occlusion can be successfully performed under guidance of transthoracic echocardiography only and appears safe and effective while avoiding radiation and contrast agent use.
Echocardiography (Mount Kisco, N.Y.) 2016
OBJECTIVE:The objective of this study was to assess the feasibility of percutaneous balloon pulmonary valvuloplasty (PBPV) under echocardiographic guidance only.SETTING:PBPV has become the preferred choice for pulmonary valve stenosis (PS). We report the first-in-human successful PBPV under only echocardiography guidance for isolated PS.METHODS:From March 2013 to December 2014, 34 patients with congenital PS underwent PBPV with echocardiography as the only imaging modality in the ordinary operation room or catheter lab. Outpatient follow-up including chest radiography, electrocardiography, and transthoracic echocardiography (TTE) was conducted at 1, 3, 6, and 12 months.RESULTS:All 34 patients successfully underwent PBPV under echocardiography guidance without radiation and contrast agent. The pulmonic transvalvular pressure gradient dropped from 62.8 ± 10.1 mm Hg to 14.7 ± 4.2 mm Hg measured on catheterization (P < .05). The balloon diameter/pulmonary annulus diameter ratio was 1.34 ± 0.07. Slight regurgitation of the pulmonary valve occurred in five patients and mild pulmonary regurgitation occurred in one patients. The pulmonic transvalvular pressure gradient measured on TTE 12 months after the procedure was 14.1 ± 4.6 mm Hg. No pericardial effusion and peripheral vascular complications occurred.CONCLUSION:This study demonstrated that PBPV can be successfully performed under only echocardiography guidance and appears safe and effective while avoiding radiation and contrast agent use.
Congenital heart disease 2016
BACKGROUND:Transesophageal echocardiogram-guided minimally invasive periventricular device closure of perimembranous ventricular septal defects (pmVSDs) without cardiopulmonary bypass is a treatment option for pmVSDs. We introduce our improvements to this technique and mid-term follow-up results.METHODS:From May 2011 to May 2014, 187 patients with pmVSDs aged 6 months to 31 years (8.2 ± 10.2 years) were enrolled in this study. The procedure was performed through a new transthoracic approach of 1 to 2 cm without sternotomy. Device selection and the operative procedure were monitored by transesophageal echocardiogram. The patients underwent follow-up examinations of echocardiography and electrocardiogram at 1 month, 3 months, 6 months, and 1 year after the operation and annually thereafter.RESULTS:The defects were closed successfully in 179 patients (95.7%), and in 8 patients the operation was converted to conventional surgical repair. Six patients (3.4%) had an incomplete right bundle branch block. One patient experienced an intermittent complete atrioventricular block on the fourth day after the operation, and sinus rhythm was restored by corticosteroid therapy after 5 days. A trivial residual shunt was observed in 8 patients (4.5%) during the procedure. The average hospital stay was 3.1 ± 0.9 days. Follow-up in all patients ranged from 1 month to 36 months (median, 12.6 months), and aortic regurgitation, malignant arrhythmia, and device dislocation were not observed in any patients. However, 3 patients (1.7%) still had a trivial residual shunt at their last follow-up.CONCLUSIONS:Periventricular device closure through a modified transthoracic approach without sternotomy is a potentially safe and effective treatment option for pmVSDs. Controlled studies with long-term follow-up are necessary.
The Annals of thoracic surgery 2015
OBJECTIVE:To avoid the injuries of radiation and contrast agent, we assess the efficacy and safety of percutaneous patent ductus arteriosus (PDA) closure by femoral vein approach solely under echocardiography guidance.METHODS:From January 2014 to December 2014, 25 patients in Fuwai hospital with PDA were selected, with mean age (4.5 ± 2.1) years and mean body weight (19 ± 7) kg. The mean diameter of PDA was (5.9 ± 1.2) mm. Patients were all treated by percutaneous PDA closure solely by echocardiography guidance in femoral vein. The effect of the procedure was evaluated by echocardiography. Follow-up was given at one month after procedure.RESULTS:Twenty-three cases were successfully treated with percutaneous PDA closure by femoral vein approach solely under echocardiography guidance, while two patients was closed by femoral artery approach because guide wires could not pass through PDA. The procedural time was (33 ± 5) min. The mean diameter of PDA occluder was (11.4 ± 1.5) mm. Postoperative early trivial residual shunt occurred in three patients. All patients survived with no peripheral vascular injury or complications such as cardiac perforation. Hospitalization time was (3.6 ± 0.8) days. At one month follow-up, no complications such as residual shunt or pericardial effusion were occurred.CONCLUSION:Echocardiography guided percutaneous PDA closure by femoral vein approach is safe and effective, and avoids the use of radiation and contrast agents.
Zhonghua yi xue za zhi 2015
OBJECTIVE:To avoid the radiation injuries and use of contrast agent, we assessed the safety and efficacy of percutaneous patent ductus arteriosus closure solely under thoracic echocardiography guidance.METHODS:From June 2013 to June 2014, thirty patients (mean age: (6.3 ± 2.5) years, mean body weight:(22.5 ± 7.3) kg) with pure patent ductus arteriosus were continuously included in this study. The mean diameter of patent ductus arteriosus was (3.8 ± 0.9) mm. Patients were all treated by percutaneous patent ductus arteriosus closure via right femoral artery solely under thoracic echocardiography guidance. The efficacy of the procedure was evaluated by thoracic echocardiography. Follow-up was performed at one month after procedure.RESULTS:All 30 cases were successfully treated with percutaneous patent ductus arteriosus closure solely under thracic echocardiography guidance. The procedural time was (32.8 ± 5.7) minutes. The mean diameter of Amplatzer ADO II was (4.9 ± 1.0) mm. Postoperative trivial residual shunt occurred in six patients immediately after the procedure. All patients survived without peripheral vascular injury or complications such as cardiac perforation. Hospitalization time was (3.4 ± 0.7) days. At one-month follow-up, no complications such as residual shunt or pericardial effusion were observed.CONCLUSION:Echocardiography guided percutaneous patent ductus arteriosus closure by femoral artery approach is safe and effective, and can avoid X-ray and the use of contrast agents.
Zhonghua xin xue guan bing za zhi 2015
OBJECTIVE:Demonstrate the benefits of percutaneous atrial septal defect (ASD) closure under guidance of transthoracic echocardiography (TTE) without fluoroscopy.METHODS:From February 2013 to April 2014, 127 consecutive patients with an isolated type II ASD were recruited to undergo percutaneous closure under either TTE (n = 60, TTE group) or TEE (n = 67, TEE group) guidance. The TTE group received local anesthesia or sedation with propofol, and the TEE group received general anesthesia with endotracheal intubation. Follow-up examinations were performed for both groups at 1 month, 3 months, 6 months, and 1 year after discharge and annually thereafter.RESULTS:The TTE group had a significantly shorter procedure time and respirator ventilation duration than the TEE group. The dose of propofol required, the cost, and the pharyngeal complication rate were significantly lower in the TTE group than in the TEE group. The median follow-up of 11.6 months was uneventful in all patients.CONCLUSIONS:Percutaneous ASD closure with TTE guidance as the only imaging tool avoids fluoroscopy, endotracheal intubation, and probe insertion and is associated with a satisfactory procedural success rate and lower costs. This procedure is a safe and reliable treatment for ASD.
Journal of interventional cardiology 2015
OBJECTIVE:To explore the feasibility of transcatheter closure of atrial septal defect (ASD) under transthoracic echocardiography (TTE) guidance.METHODS:Retrospective analysis was performed in 65 patients with simple ASD who underwent transcatheter closure under echocardiography guidance in Fuwai hospital from February to August 2013. They were divided into TTE group (n = 30) and transesophageal echocardiography (TEE) group (n = 35). The TTE group patients who underwent localized anesthesia or basal anesthesia received transcatheter closure of ASD under the guidance of TTE. The TEE group patients who underwent tracheal intubation and general anesthesia received transcatheter closure of ASD under the guidance of TEE. The patients were followed up with TTE and electrocardiogram at one month after procedure at outpatient department.RESULTS:In the TTE group, 28 occluders were implanted successfully and 2 patients were subsequently switched to TEE guidance because of unclear TTE images, and the occluder implantation in these 2 patients was successful. There were no obvious differences in age, sex, body weight, ASD size, and time of hospital stay between the two groups (all P > 0.05) . Compared with TEE group, the TTE group had a significantly shorter operation time ((52.77 ± 9.00 ) min vs. (60.11 ± 9.15) min, P < 0.05), respirator ventilation duration ((0.25 ± 0.95) h vs. (3.17 ± 0.69) h, P < 0.05), and stay time in ICU ((1.50 ± 1.96) h vs. (16.43 ± 6.99) h, P < 0.05). The dose of propofol required was significantly lower in the TTE group compared to TEE group ((2.41 ± 2.97) mg/kg vs. (9.43 ± 3.70) mg/kg, P < 0.05). The patients in both groups had no complications such as residual shunt, peripheral vascular injury or cardiac perforation at the time of hospitalization.No complications, such as occluder dislocation, residual shunt, or pericardial effusion were seen during follow-up at one month post procedure in both groups.CONCLUSION:Transcatheter closure of ASD under TTE guidance is feasible and has a broad application prospects.
Zhonghua xin xue guan bing za zhi 2014
OBJECTIVE:To assess the safety and effectiveness of percutaneous transcatheter closure of atrial septal defect (ASD) under transesophageal echocardiography (TEE) guidance in children.METHODS:The study included 20 cases of patients with ASD. The patients were (4.2 ± 1.2) years old and the mean body weights were (18.2 ± 4.2) kg. The diameter of ASD before closure was (13.4 ± 3.3) mm . All procedures were guided under TEE. Procedure success was evaluated by TEE immediately after procedure.RESULTS:Closure devices were successfully implanted in all 20 patients under TEE guidance. The diameter of closure devices was 14-26 mm. There were no procedure related complications. The ventilation time was (2.9 ± 0.8)h and the hospitalization time was (3.2 ± 0.7) days.CONCLUSION:TEE guided percutaneous transcatheter closure is safe and effective for patients with ASD and avoids the radiation damages.
Zhonghua xin xue guan bing za zhi 2013