薛潇迪
中国医学科学院阜外医院 心血管内科
Objectives:This study aims to investigate the association between waist circumference (WC) and cardiovascular death in patients with permanent pacemakers (PPMs).Methods:This is a retrospective cohort study that enrolled patients who underwent PPM implantation in Fuwai Hospital from May 2010 to April 2014, according to the BIOTRONIK Home Monitoring database. The WC was treated as sex-specific quartiles, and patients were divided into three groups according to body mass index (BMI): normal (≤22.9 kg/m2), overweight (23-24.9 kg/m2), and obese (≥25 kg/m2). Cox proportional hazards models were used to calculate hazard ratios and 95% confidence intervals for cardiovascular death according to WC and BMI in patients.Results:492 patients with PPMs implantation were analyzed (mean age: 71.9 ± 10.8 years; 55.1% men (n = 271)). Data showed that after a mean follow-up 67.2 ± 17.5 months, 24 (4.9%) patients had experienced cardiovascular death and 71 (14.4%) were cases of all-cause mortality. Men in the third quartile of WC had an HR of 10.67 (Model 4, 95% CI: 1.00-115.21, p trend = 0.04) for cardiovascular death. However, the association disappeared in female patients (Model 4, HR = 3.99, 95% CI: 0.37-42.87, p trend = 0.25). There was no association between BMI and cardiovascular death or all-cause mortality in both male and female patients.Conclusions:Abdominal obesity was associated with an increased risk of cardiovascular death in patients with PPMs, and this relationship was only in male patients.
Evidence-based complementary and alternative medicine : eCAM 2023
OBJECTIVE:To investigate whether plasma big endothelin-1 (ET-1) predicts ventricular arrythmias (VAs) and end-stage events in primary prevention implantable cardioverter-defibrillator (ICD) indication patigents.METHODS:In total, 207 patients fulfilling the inclusion criteria from Fuwai Hospital between January 2013 and December 2015 were retrospectively analyzed. The cohort was divided into three groups according to baseline plasma big ET-1 tertiles: tertile 1 (< 0.38 pmol/L, n = 68), tertile 2 (0.38-0.7 pmol/L, n = 69), and tertile 3 (> 0.7 pmol/L, n = 70). The primary endpoints were VAs. The secondary endpoints were end-stage events comprising all-cause mortality and heart transplantation.RESULTS:During a mean follow-up period of 25.6 ± 13.9 months, 38 (18.4%) VAs and 78 (37.7%) end-stage events occurred. Big ET-1 was positively correlated with NYHA class (r = 0.165, P = 0.018), serum creatinine concentration (Scr; r = 0.147, P = 0.034), high-sensitivity C-reactive protein (hs-CRP; r = 0.217, P = 0.002), Lg NT-pro BNP (r = 0.463, P < 0.001), left ventricular end diastolic diameter (LVEDD; r = 0.234, P = 0.039) and negatively correlated with left ventricular ejection fraction (LVEF; r = -0.181, P = 0.032). Kaplan-Meier analysis showed that elevated big ET-1 was associated with increased risk of VAs and end-stage events (P < 0.05). In multivariate Cox regression models, big ET-1 was an independent risk factor for VAs (hazard ratio (HR) = 3.477, 95% confidence interval (CI): 1.352-8.940, P = 0.010, tertile 2 vs. tertile 1; HR = 4.112, 95% CI: 1.604-10.540, P = 0.003, tertile 3 vs. tertile 1) and end-stage events (HR = 2.804, 95% CI: 1.354-5.806, P = 0.005, tertile 2 vs. tertile 1; HR = 4.652, 95% CI: 2.288-9.459, P < 0.001, tertile 3 vs. tertile 1).CONCLUSIONS:In primary prevention ICD indication patients, plasma big ET-1 levels can predict VAs and end-stage events and may facilitate ICD-implantation risk stratification.
Journal of geriatric cardiology : JGC 2020
OBJECTIVE:To investigate the obesity paradox and its interrelationship with objective physical activity (PA) in patients at high risk of sudden cardiac death.METHODS:A total of 782 patients with implantable cardioverter-defibrillators/cardiac resynchronization therapy defibrillators in the Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device-Implantable Patients registry were retrospectively analyzed and grouped by body mass index (BMI) (kg/m2): normal weight (18.5 ≤ BMI < 25) and overweight or class I obesity (25 ≤ BMI < 35). PA was measured with home monitoring and categorized into 4 groups (Q1-Q4) by the baseline quartiles. The main endpoint was all-cause mortality.RESULTS:During a mean follow-up period of 59.9 ± 21.9 months, 182 all-cause mortality events occurred. Mortality tended to be lower in overweight and obesity patients (18.9% vs 25.1%, P = 0.061) and decreased by PA quartiles (44.1% vs 22.6% vs 15.3% vs 11.2%, Q1-Q4, P < 0.001). Multivariate Cox analysis indicated BMI (hazard ratio, 0.918; 95% confidence interval, 0.866-0.974; P = 0.004) and PA (0.436, 0.301-0.631, Q2 vs Q1; 0.280, 0.181-0.431, Q3 vs Q1; 0.257, 0.158-0.419, Q4 vs Q1; P < 0.001 for all) were associated with reduced risk. The obesity paradox was significant in the total cohort (log rank P = 0.049) and low PA group (log rank P = 0.010), but disappeared in the high PA group (log rank P = 0.692). Dose-response curves showed a significant reduction in risk with low-moderate PA, and the pattern varied between different BMI groups.CONCLUSIONS:The obesity paradox only persisted in physically inactive patients. PA might be related to the development of the obesity paradox.
The Journal of clinical endocrinology and metabolism 2020
Objective: To clarify the impact of sex on physical activity (PA) levels among patients with implantable cardioverter-defibrillators/cardiac resynchronization therapy defibrillators (ICD/CRT-D) and its association with cardiac death and all-cause mortality. Methods: Overall, data of 820 patients with ICD/CRT-D from the SUMMIT registry were retrospectively analyzed. Baseline PA from 30 to 60 days after device implantation was measured using Biotronik accelerometer sensors. The primary and secondary endpoints were cardiac death and all-cause mortality, respectively. Results: Baseline PA levels were significantly higher in male patients than in female patients (11.40 ± 5.83% vs. 9.93 ± 5.49%, P = 0.001). Males had higher predictive PA cut-off values for cardiac death (11.16 vs. 7.15%) and all-cause mortality (11.33 vs. 7.17%). During the median follow-up time of 75.7 ± 29.1 months, patients with baseline PA Frontiers in cardiovascular medicine 2020
BACKGROUND:Previous studies have reported inconsistent results on the relationship between body mass index (BMI) and clinical outcomes in implantable cardioverter defibrillator (ICD) patients. Additionally, research on ICD patients with nonischemic cardiomyopathy (NICM) is lacking.HYPOTHESIS:This study aimed to investigate the impact of BMI on mortality and ventricular arrhythmias (VAs) in NICM patients with an ICD.METHODS:This study retrospectively analyzed the data from the Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device-implanted patients (SUMMIT) in China. Four hundred and eighty NICM patients with an ICD having BMI data were enrolled. Patients were divided into two groups: underweight and normal range group (BMI < 24 kg/m2 ), overweight and obese group (BMI≥24 kg/m2 ). The primary endpoint was all-cause mortality. The secondary endpoint was the first occurrence of VAs requiring appropriate ICD therapy or shock.RESULTS:During a median follow-up of 61 (1-95) months, 70 patients (14.6%) died, 173 patients (36%) experienced VAs requiring appropriate ICD therapy, and 112 patients (23.3%) were treated with ICD shock. Multivariate Cox regression modeling indicated a decreased mortality risk in the overweight and obese group compared with the underweight and normal range group (hazard ratio = 0.44, 95% confidence interval 0.26-0.77, P = .003). However, the risk of VAs was similar in both groups in univariate and multivariate Cox models.CONCLUSIONS:Compared with underweight and normal weight, overweight and obesity are protective against mortality but have only a neutral impact on VAs risk in NICM patients with an ICD.
Clinical cardiology 2020