Anatomical variation of femoral vessels and ultrasound-guided femoral vein puncture for catheter ablation of arrhythmias.

OBJECTIVE:This study aims to investigate the anatomical variations in femoral vasculature and evaluate the clinical value of ultrasound-guided femoral vein puncture in catheter ablation procedures.METHODS:In this retrospective analysis conducted from January 2023 to March 2023, we examined data from patients who underwent catheter ablation with ultrasound-guided femoral venipuncture. We evaluated the anatomy of the femoral vasculature at both high and low inguinal levels. Based on the relationship between the femoral vein and artery, we classified the anatomy into four types: Type I (vein parallel to artery without overlap), Type II (vein medial to artery with lumen overlap ≤50%), Type III (vein posterior to artery with lumen overlap > 50%), and Type IV (vein lateral to artery). Additionally, we assessed procedure-related vascular complications that required interventions or prolonged hospital stays.RESULTS:A total of 254 patients were included in this study. At the upper inguinal level, most cases (92.5%) exhibited Type II, followed by Type I (6.5%), while Type III (0.6%) and IV (0.4%) were less common. At the lower inguinal level, Type II accounted for 70.7%, there was a significantly higher proportion of Type III (23.4%) and Type IV (5.9%). The overall complication rate was 0.4%, no pseudoaneurysm or hematoma was observed in our study.CONCLUSION:Our study revealed significant anatomical variations in the relationship between the femoral vein and femoral artery. Ultrasound-guided femoral venipuncture significantly reduced vascular complication rate, making it a valuable tool for guiding puncture procedures.

1.8
4区

Pacing and clinical electrophysiology : PACE 2024

Radial and Circumferential CMR-Based RV Strain Predicts Low R Wave Amplitude after ICD Implantation in Patients with Arrhythmogenic Cardiomyopathy.

Inadequate R wave amplitude (RWA) after implantable cardiac defibrillator (ICD) implantation in patients with arrhythmogenic cardiomyopathy (ACM) was suspected to relate to right ventricle impairment. However, little data-based evidence was provided to quantify the association. We retrospectively enrolled ACM patients receiving CMR examinations before transvenous ICD implantation from Fuwai Hospital. The RWA was obtained within 24 h and at 2-6-month follow-up after the operation. Structural, functional, as well as tissue characterization of the left ventricle (LV) and right ventricle (RV), were analyzed in relation to RWA. Among the 87 ACM patients (median RWA: 8.0 mV), 19 (21.8%) patients were found with low initial RWA (<5 mV) despite attempts in multiple positions. RV end diastolic diameter (RVEDD), (r = -0.44), RV ejection fraction (RVEF, r = 0.43), RV end diastolic volume index (RVEDVi, r = -0.49), RV end systolic volume index (RVESVi, r = -0.53), RV global circumferential (RVGCS, r = -0.64), and radial strain (RVGRS, r = 0.61, all p < 0.001) rather than LV metrics correlated strongly with initial RWA. RVGCS, RVESVi, and RVGRS were decent predictors of low RWA (areas under the curve AUC: 0.814, 0.769, 0.757, respectively) early after implantation and during 2-6-month follow-up. To summarize, low RWA of ICD lead in ACM patients was associated with RV abnormalities. The RVGCS, RVGRS, and RVESVi can be valuable predictors for identifying low RWA prior to ICD implantation.

3.9
3区

Journal of clinical medicine 2023

Progression of Device-Detected Atrial High-Rate Episodes and the Risk of All-Cause Mortality.

Atrial high-rate episodes (AHREs) are prevalent in approximately 1/3 of patients with cardiac implanted electronic devices and are associated with an increased risk of several adverse outcomes. This study aimed to explore the factors associated with AHRE progression and the risk of all-cause mortality. At least 1 day with AHRE burden ≥15 minutes was identified in 124 of 343 recipients (36.2%) of an implantable cardioverter defibrillator or cardiac resynchronization therapy device. We included patients whose AHRE burden at the time of first detection was ≥15 minutes but <24 hours (n = 107). Various cut-off values (15 minutes, 6 hours, and 24 hours) of daily AHRE burden were analyzed. During an average follow-up of 4.2 years, 60 patients (56.1%) experienced ≥1 progression to greater AHRE burden. Patients with hypertension or greater AHRE burden at first detection were associated with faster progression. In addition, 27 deaths (45%) occurred among 60 patients with AHRE progression, compared with 25.5% (12 of 47) for those without progression. After multivariable adjustment, AHRE progression was independently associated with all-cause mortality (hazard ratio 2.56, 95% confidence interval 1.23 to 5.35, p = 0.012). Notably, AHRE progression within 1 month after their first detection was associated with an increased risk for all-cause mortality (hazard ratio 4.01, 95% confidence interval 1.76 to 9.16, p = 0.001) compared with patients without progression. However, a similar risk was not observed among patients with AHRE progression occurring after 1 month after their first detection. In conclusion, >1/2 of the patients with AHRE progressed to a greater burden over time. Continuous monitoring of the AHRE burden may help identify patients at great risk for death.

2.8
3区

The American journal of cardiology 2023

Cardiac magnetic resonance-derived myocardial scar is associated with echocardiographic response and clinical prognosis of left bundle branch area pacing for cardiac resynchronization therapy.

AIMS:Left bundle branch area pacing (LBBAP) is a novel approach for cardiac resynchronization therapy (CRT), but the impact of myocardial substrate on its effect is poorly understood. This study aims to assess the association of cardiac magnetic resonance (CMR)-derived scar burden and the response of CRT via LBBAP.METHODS AND RESULTS:Consecutive patients with CRT indications who underwent CMR examination and successful LBBAP-CRT were retrospectively analysed. Cardiac magnetic resonance late gadolinium enhancement was used for scar assessment. Echocardiographic reverse remodelling and composite outcomes (defined as all-cause death or heart failure hospitalization) were evaluated. The echocardiographic response was defined as a ≥15% reduction of left ventricular end-systolic volume. Among the 54 patients included, LBBAP-CRT resulted in a 74.1% response rate. The non-responders had higher global, septal, and lateral scar burden (all P < 0.001). Global, septal, and lateral scar percentage all predicted echocardiographic response [area under the curve (AUC): 0.857, 0.864, and 0.822; positive likelihood ratio (+LR): 9.859, 5.594, and 3.059; and negative likelihood ratio (-LR): 0.323, 0.233, and 0.175 respectively], which was superior to QRS morphology criteria (Strauss left bundle branch abnormality: AUC: 0.696, +LR 2.101, and -LR 0.389). After a median follow-up time of 20.3 (11.5-38.7) months, higher global, lateral and septal scar burdens were all predictive of the composite outcome (hazard ratios: 4.996, 7.019, and 4.741, respectively; P's < 0.05).CONCLUSION:Lower scar burden was associated with higher response rate of LBBAP-CRT. The pre-procedure CMR scar evaluation provides further useful information to identify potential responders and clinical outcomes.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2023

Additional left ventricular septal lead facilitates R-wave sensing of implantable cardioverter-defibrillator in arrhythmogenic right ventricular cardiomyopathy: a case report.

Background:Implantable cardioverter-defibrillator (ICD) implantation is a key therapeutic option in arrhythmogenic right ventricular cardiomyopathy (ARVC) to prevent sudden cardiac death due to ventricular tachycardia (VT) and fibrillation (VF). However, sub-optimized R-wave sensing due to myocardium loss interferes with VT/VF identification and appropriate therapy. We tried to implant a 3830 lead to the left ventricular septum (LVS) to facilitate ICD sensing in an ARVC patient.Case summary:A 68-year-old woman diagnosed with ARVC was scheduled to undergo ICD implantation. Initially, no sites with suitable R-wave amplitudes were found in the right ventricle (RV) to deploy the defibrillation lead (<3.0 mV). It was likely due to severe RV involvement, but the LVS myocardium was more preserved based on cardiac magnetic resonance imaging. Therefore, we implanted a 3830 lead into the deep area of the septum to facilitate R-wave sensing. During the procedure from the right to left septum, the R-wave amplitude significantly increased (2.6 to 4.3-7.1 mV). Left ventricular septum pacing was finally achieved with favourable R-wave sensing (9.9 mV 24 h post-operation). The 3830 lead was plugged into the IS-1 port, while the defibrillation lead was plugged into the DF-1 port. After a 4-month follow-up, the R-wave amplitude of the 3830 lead was 11.1 mV.Discussion:When the R-wave sensing is not acceptable for ICD implantation in ARVC patients, it is critical to assess myocardial conditions comprehensively. If the septal myocardium is preserved, implanting a 3830 lead to the deep or LVS is feasible to improve R-wave sensing.

1.0

European heart journal. Case reports 2023

Device-evaluated autonomic nervous function for predicting ventricular arrhythmias and all-cause mortality in patients who underwent cardiac resynchronization therapy-defibrillator.

Introduction: Autonomic nervous system (ANS) function quantified by heart rate variability (HRV) was associated with long-term prognosis, but it was rarely used in the evaluation of patients with heart failure, especially those with cardiac resynchronization therapy-defibrillator (CRT-D) implantation. This study aimed to describe the changes in ANS function among patients who underwent CRT-D with remote home monitoring function, and explore predictive value of HRV for ventricular tachyarrhythmias (VTAs) and all-cause mortality. Method: Patients who underwent CRT-D implantation were included. Device-measured all-day HR, night-time HR, and HRV (measured by the standard deviation of the atrial-atrial sensed intervals) were used to quantify ANS function. Multivariate Cox proportional hazards models were fitted to calculate hazard ratios (HRs) and 95% confidence intervals (CIs) of VTAs or all-cause mortality in relation to ANS function at baseline and 6 months post-implantation. The cutoff value was determined using restrictive cubic splines. Multivariable logistic regression was further established to determine factors influencing postoperative HRV. Results: A total of 170 patients treated with CRT-D were eligible for analysis. During a median follow-up period of 50.8 months, 61 patients died and 69 patients experienced at least one spontaneous episode of VTAs. At 6 months after CRT implantation, 114 patients showed improvement in HRV, increasing from 66.4 ± 19.4 ms to 76.7 ± 21.2 ms. The postoperative HRV was associated with both all-cause mortality (HRs: 0.983; 95% CI: 0.968 to 0.998, p = 0.012) and VTAs (HRs: 0.973; 95% CI: 0.954 to 0.993, p = 0.008), and the relative risk would significantly increase when the postoperative HRV lower than 75 ms. After adjusting for basic ANS function and possible influencing factors, patients without diabetes (p = 0.018) and with higher daily physical activity (p = 0.041) could maintain higher postoperative HRV after CRT implantation. Conclusion: More than two-thirds of heart failure patients showed improvement in ANS function following CRT treatment. However, patients with diabetes and low daily physical activity levels have difficulty maintaining a higher postoperative HRV, which is associated with a worse clinical outcome.

4.0
3区

Frontiers in physiology 2023

Clinical use conditions of lead deployment and simulated lead fracture rate in left bundle branch area pacing.

INTRODUCTION:Left bundle branch area pacing (LBBAP) is achieved by advancing the lead tip deep in the septum. Most LBBAP implants are performed using the Medtronic SelectSecure™ MRI SecureScan™ Model 3830 featuring a unique 4 Fr fixed helix lumenless design. Details of lead use conditions and long-term reliability have not been reported. This study was designed to quantify the mechanical use conditions for the 3830 lead during and after LBBAP implant, and to evaluate reliability using bench testing and simulation.METHODS:Fifty bradycardia patients with implantation of the 3830 lead for LBBAP were enrolled. Use conditions of lead deployment at implantation were collected and computed tomography (CT) scans were performed at 3-month follow-up. Curvature amplitude along the pacing lead was determined with CT images. Fatigue bending was performed using accelerated testing in a more severe environment than routine clinical use conditions. Conductor fracture rate in a simulated patient population was estimated based on clinical use conditions and fatigue test results.RESULTS:The number of attempts to place the 3830 lead for LBBAP was 2.1 ± 1.3 (range: 1-7) with 13 ± 6 lead rotations at the final attempt. Extreme implant conditions were simulated in bench testing with 5 applications of 20 turns followed by up to 400 million bending cycles. Reliability modeling predicted a 10-year fracture rate of 0.02%.CONCLUSIONS:LBBAP implants require more lead rotations than standard pacing implants and result in unique lead bending. Application of simulated LBBAP use conditions to the 3830 lead in an accelerated in-vitro model does not produce excess conductor fractures. IMAGE-LBBP Study ID of ClinicalTrial.GOV: NCT04119323.

2.7
3区

Journal of cardiovascular electrophysiology 2023

Association of device-detected atrial high-rate episodes with long-term cardiovascular and all-cause mortality: a cohort study.

BACKGROUND:Device-detected atrial high-rate episodes (AHREs) were associated with an increased thromboembolic risk. Although limited data regarding the long-term prognosis of patients with AHRE were controversial, this study aimed to identify the association of device-detected AHRE with mortality.METHODS:This observational study included patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) placement and no history of atrial fibrillation (AF), atrial flutter (AFL), or atrial tachycardia (AT). During follow-up, patients with at least 1 day of AHRE duration ≥ 15 minutes were identified. The primary endpoint was cardiovascular mortality, and the secondary endpoint was all-cause mortality.RESULTS:During a mean follow-up period of 4.2 years, AHREs were detected in 124 of 343 (36.2%) patients. Of these, 44 deaths (35.5%) occurred in 124 patients with AHREs, which was significantly higher than those without AHREs (43 of 219; 19.6%; P = 0.001). The multivariate analysis revealed that patients with AHRE had a significantly higher risk of cardiovascular (hazard ratio [HR], 2.40; 95% confidence interval [CI], 1.23-4.67; P = 0.010), and all-cause mortality (HR, 2.31; 95% CI, 1.49-3.59; P < 0.001). Further analysis indicated that this association remained significant in patients with higher burden (≥ 6 hours) but not in patients with lower burden (≥ 15 minutes to 6 hours). Notably, even after excluding the patients diagnosed with clinical AF during follow-up, the remaining patients with AHREs still exhibited a higher risk of cardiovascular and all-cause mortality compared with patients without AHREs.CONCLUSIONS:AHREs were prevalent in ICD or CRT-D recipients with no history of clinical AF, AFL, or AT and were associated with more than twice the risk of cardiovascular and all-cause mortality.CLINICAL TRIAL REGISTRATION:No. ChiCTR-ONRC-13003695.

6.2
2区

The Canadian journal of cardiology 2023

Efficacy and Safety of Leadless Pacemakers for Atrioventricular Synchronous Pacing: A Systematic Review and Meta-Analysis.

Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of this new technology. We systematically searched the PubMed, Embase, and Cochrane library databases from their inception to 12 September 2022. The primary efficacy outcome was atrioventricular synchrony after implantation, whereas the secondary efficacy outcome was the change in cardiac output represented by the left ventricular outflow tract velocity time integral (LVOT-VTI). The primary safety outcome was major complications related to the procedures and the algorithm. Means or mean differences with 95% confidence interval (95% CI) were combined using a random-effects model or a fixed-effects model. Finally, 8 published studies with 464 participants were included in the qualitative analysis. The pooled atrioventricular synchrony proportion was 78.9% (95% CI 71.9-86.0%), and a further meta-regression did not screen factors that contributed significantly to the heterogeneity. Additionally, a significant increase in atrioventricular synchrony of 11.3% (95% CI 7.0-15.7%, p < 0.01) was achieved in patients experiencing programming optimization. LVOT-VTI was significantly increased by 1.9 cm (95% CI 1.2-2.6, p < 0.01), compared with the VVI pacing mode. The overall incidence of complications was approximately 6.3%, with major complications related to the algorithm being extremely low. Overall, leadless pacemakers with atrioventricular synchronous pacing demonstrated favorable safety and efficacy. Future data on their long-term performance are required to facilitate their widespread adoption in clinical practice.

3.9
3区

Journal of clinical medicine 2023

Sex Differences in the Relationship between Abdominal Obesity and Cardiovascular Death in Elderly Patients with Permanent Pacemakers Implantation: A Retrospective Cohort Study.

Objectives:This study aims to investigate the association between waist circumference (WC) and cardiovascular death in patients with permanent pacemakers (PPMs).Methods:This is a retrospective cohort study that enrolled patients who underwent PPM implantation in Fuwai Hospital from May 2010 to April 2014, according to the BIOTRONIK Home Monitoring database. The WC was treated as sex-specific quartiles, and patients were divided into three groups according to body mass index (BMI): normal (≤22.9 kg/m2), overweight (23-24.9 kg/m2), and obese (≥25 kg/m2). Cox proportional hazards models were used to calculate hazard ratios and 95% confidence intervals for cardiovascular death according to WC and BMI in patients.Results:492 patients with PPMs implantation were analyzed (mean age: 71.9 ± 10.8 years; 55.1% men (n = 271)). Data showed that after a mean follow-up 67.2 ± 17.5 months, 24 (4.9%) patients had experienced cardiovascular death and 71 (14.4%) were cases of all-cause mortality. Men in the third quartile of WC had an HR of 10.67 (Model 4, 95% CI: 1.00-115.21, p trend = 0.04) for cardiovascular death. However, the association disappeared in female patients (Model 4, HR = 3.99, 95% CI: 0.37-42.87, p trend = 0.25). There was no association between BMI and cardiovascular death or all-cause mortality in both male and female patients.Conclusions:Abdominal obesity was associated with an increased risk of cardiovascular death in patients with PPMs, and this relationship was only in male patients.

4区