颜汉坤
中国医科大学附属盛京医院 放射科
Background:This study sought to evaluate the association between coronary plaque characteristics, changes in the fractional flow reserve (FFR) derived from computed tomography across the lesion (ΔFFRCT), and lesion-specific ischemia using the FFR in patients with suspected or known coronary artery disease.Methods:The study assessed coronary computed tomography (CT) angiography stenosis, plaque characteristics, ΔFFRCT, and FFR in 164 vessels of 144 patients. Obstructive stenosis was defined as stenosis ≥50%. An area under the receiver -operating characteristics curve (AUC) analysis was conducted to define the optimal thresholds for ΔFFRCT and the plaque variables. Ischemia was defined as a FFR of ≤0.80.Results:The optimal cut-off value of ΔFFRCT was 0.14. Low-attenuation plaque (LAP) ≥76.23 mm3 and a percentage aggregate plaque volume (%APV) ≥28.91% can be used to predict ischemia independent of other plaque characteristics. The addition of LAP ≥76.23 mm3 and %APV ≥28.91% improved the discrimination (AUC, 0.742 vs. 0.649, P=0.001) and reclassification abilities [category-free net reclassification index (NRI), 0.339, P=0.027; relative integrated discrimination improvement (IDI) index, 0.093, P<0.001] of the assessments compared to the stenosis evaluation alone, and the addition of information about ΔFFRCT ≥0.14 further increased the discrimination (AUC, 0.828 vs. 0.742, P=0.004) and reclassification abilities (NRI, 1.029, P<0.001; relative IDI, 0.140, P<0.001) of the assessments.Conclusions:The addition of the plaque assessment and ΔFFRCT to the stenosis assessments improved the identification of ischemia compared to the stenosis assessment alone.
Quantitative imaging in medicine and surgery 2023
BACKGROUND:The association between pericoronary fat attenuation index (FAI), plaque characteristics, and lesion-specific ischemia identified by fractional flow reserve (FFR) remains unclear.METHODS:Coronary computed tomography angiography (CCTA) stenosis, FAI, plaque characteristics, FFR derived from computed tomography (FFRCT) and FFR were assessed in 280 vessels of 247 patients. Stenosis ≥50% was considered obstructive. Optimal thresholds of FAI and plaque variables were defined by the area under the receiver-operating characteristics curve (AUC) analysis. Ischemia was defined by FFR ≤ 0.80.RESULTS:FAI ≥ -71.9 HU, low-attenuation plaque (LAP) ≥ 49.62 mm3 and aggregate plaque volume (APV) ≥ 28.91% predicted ischemia independent of other plaque characteristics. The addition of FAI ≥ -71.9 HU improved discrimination (AUC, 0.720 vs. 0.674, P = 0.035) and reclassification abilities (category-free net reclassification index [NRI], 0.470, P < 0.001; relative integrated discrimination improvement [IDI], 0.047, P < 0.001) of ischemia compared with stenosis evaluation alone, with further discrimination (AUC, 0.772 vs. 0.720, P = 0.028) and reclassification abilities (NRI, 0.385, P = 0.001; relative IDI, 0.077, P < 0.001) of ischemia by adding information regarding LAP ≥49.62 mm3 + APV ≥ 28.91%. And the diagnostic performance of combination approach was comparable to that of FFRCT alone (AUC, 0.772 vs. 0.762, P = 0.771).CONCLUSIONS:Stenosis severity, FAI, plaque characteristics predicted lesion-specific ischemia. The combination of FAI and plaque assessment improved the discrimination of ischemia compared with stenosis assessment alone.
International journal of cardiology 2022
Aim:The quantitative flow ratio (QFR) is favorable for functional assessment of coronary artery stenosis without pressure wires and induction of hyperemia. The aim of this study was to explore whether angiographic lesion morphology provides incremental value to generalize QFR for predicting myocardial ischemia in unselected patients.Methods:This study was a substudy to the CT-FFR CHINA trial, referring 345 participants from five centers with suspected coronary artery disease on coronary CT angiography for diagnostic invasive coronary angiography (ICA). Fractional flow reserve (FFR) was measured in all vessels with 30-90% diameter stenosis. QFR was calculated in 186 lesions from 159 participants in a blinded manner. In addition, parameters to characterize lesion features were recorded or measured, including left anterior descending arteries (LADs)-involved lesions, side branch located at stenotic lesion (BL), multiple lesions (ML), minimal lumen diameter (MLD), reference lumen diameter (RLD), percent diameter stenosis (%DS), lesion length (LL), and LL/MLD4. Logistic regression was used to construct two kinds of models by combining single or two lesion parameters with the QFR. The performances of these models were compared with that of QFR on a per-vessel level.Results:A total of 148 participants (mean age: 59.5 years; 101 men) with 175 coronary arteries were included for final analysis. In total, 81 (46%) vessels were considered hemodynamically significant. QFR correctly classified 82.29% of the vessels using FFR with a cutoff of 0.80 as reference standard. The area under the receiver operating characteristic curve (AUC) of QFR was 0.86 with a sensitivity, specificity, positive predictive value, and negative predictive value of 80.25, 84.04, 81.25, and 83.16%, respectively. The combined models (QFR + LAD + MLD, QFR + LAD + %DS, QFR + BL + MLD, and QFR + BL + %DS) outperformed QFR with higher AUCs (0.91 vs. 0.86, P = 0.02; 0.91 vs. 0.86, P = 0.02; 0.91 vs. 0.86, P = 0.02; 0.90 vs. 0.86, P = 0.03, respectively). Compared with QFR, the sensitivity of the combined models (QFR + BL and QFR + MLD) was improved (91.36 vs. 80.25%, 91.36 vs. 80.25%, respectively, both P < 0.05) without compromised specificity or accuracy.Conclusion:Combined with angiographic lesion parameters, QFR can be optimized for predicting myocardial ischemia in unselected patients.
Frontiers in cardiovascular medicine 2022
Background:It is unclear whether tube voltage influences the measurement of perfusion parameters. The present study sought to evaluate the influence of tube voltage change on myocardial blood flow (MBF) measurements in dynamic computed tomography myocardial perfusion imaging (CTP).Methods and Results:Seven swine [mean weight 55.8 kg ± 1.6 (standard deviation)] underwent rest and stress dynamic CTP with tube voltages of 100 and 70 kV. The image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose and MBF value were compared. The 70 kV images had higher CT attenuation and higher image noise (27.9 ± 2.4 vs. 21.5 ± 1.9, P < 0.001) than the 100 kV images, resulting in a higher SNR (20.5 ± 1.6 vs. 15.6 ± 1.8, P < 0.001) and CNR (17.6 ± 1.5 vs. 12.4 ± 1.7, P < 0.001). Compared to the use of conventional 100 kV, 70 kV yielded an approximately 64.6% radiation dose reduction while generating comparable MBF values, both at rest (88.3 ± 14.9 ml/100 g/min vs. 85.6 ± 17.4 ml/100 g/min, P = 0.21) and stress (101.4 ± 21.5 ml/100 g/min vs. 99.6 ± 21.4 ml/100 g/min, P = 0.58) states.Conclusion:Dynamic CTP using 70 kV instead of 100 kV does not substantially influence the MBF value but significantly reduces the radiation dose. Additional research is required to investigate the clinical significance of this change.
Frontiers in cardiovascular medicine 2022
Background: Coronary computed tomography angiography (CCTA) is an established first-line test in the investigation of patients with suspected coronary artery disease (CAD), while the perivascular fat attenuation index (FAI) derived from CT seems to be a feasible and efficient tool for the identification of ischemia. The association between the FAI and lesion-specific ischemia as assessed by fractional flow reserve (FFR) remains unclear. Methods: In a total of 261 patients, 294 vessels were assessed for CCTA stenosis, vessel-specific FAI, lesion-specific FAI, and plaque characteristics. The diagnostic accuracies of each parameter and the combined approach were analyzed via the receiver operating characteristic curve (ROC) with FFR as the reference standard. The determinants of FAI were statistically analyzed. Results: The cutoff values of vessel-specific FAI and lesion-specific FAI scores calculated according to the Youden index were −70.97 and −73.95 HU, respectively. No significant differences were noted between them; however, they exhibited a strong correlation. No significant differences were noted between the area under the curve (AUC) scores of vessel-specific FAI (0.677), lesion-specific FAI (0.665), and CCTA (0.607) (p > 0.05 for all) results. The addition of two FAI measures to the CCTA showed improvements in the discrimination (AUC) and reclassification ability (relative integrated discrimination improvement (IDI) and category-free net reclassification index (NRI)), vessel-specific FAI (AUC, 0.696; NRI, 49.6%; IDI, 5.9%), and lesion-specific FAI scores (AUC, 0.676; NRI, 43.3%; IDI, 5.4%); (p < 0.01 for all). Multivariate analysis revealed that low-attenuation plaque (LAP) volume was an independent predictor of two FAI measures. Conclusion: The combined approach of adding vessel-specific FAI or lesion-specific FAI scores could improve the identification of ischemia compared with CCTA alone. The LAP volume was the independent risk factor for both tools.
Journal of cardiovascular development and disease 2022
Aims: This study sought to evaluate the diagnostic performance of change in computed tomography-derived fractional flow reserve (CT-FFR) across the lesion (ΔCT-FFR) for identifying ischemia lesions with FFR as the reference standard. Methods: Patients who underwent coronary CT angiography (CCTA) and FFR measurement within 1 week from December 2018 to December 2019 were retrospectively enrolled. CT-FFR within 2 cm distal to the lesion, ΔCT-FFR and plaque characteristics were analyzed. The diagnostic accuracy of CCTA (coronary stenosis ≥ 50%), CT-FFR ≤ 0.80, and ΔCT-FFR ≥ 0.15 (based on the largest Youden index) were assessed with FFR as the reference standard. The relationship between plaque characteristics and ΔCT-FFR was analyzed. Results: The specificity of ΔCT-FFR and CT-FFR were 70.8 and 67.4%, respectively, which were both higher than CCTA (39.3%) (both P < 0.001), while there were no statistical significance in sensitivity among the three (84.5, 77.4, 88.1%, respectively; P = 0.08). The area under the curves (AUCs) of ΔCT-FFR and CT-FFR were 0.803 and 0.743, respectively, which were both higher than that of CCTA (0.637) (both P < 0.05), and the AUC of ΔCT-FFR was higher than that of CT-FFR (P < 0.001). Multivariable analysis showed that low-attenuation plaque (LAP) volume (odds ratio [OR], 1.006) and plaque length (OR, 1.021) were independently correlated with ΔCT-FFR (both P < 0.05). Conclusions: CT-FFR and ΔCT-FFR and here especially the ΔCT-FFR could improve the diagnostic performance of ischemia compared with CCTA alone. LAP volume and plaque length were the independent risk factors of ΔCT-FFR.
Frontiers in cardiovascular medicine 2021