唐跃
中国医学科学院阜外医院
Zhonghua xin xue guan bing za zhi 2023
BACKGROUND:The main treatment for a ruptured sinus of Valsalva aneurysm (SVA) is surgical repair. Postoperative progression of aortic regurgitation (AR) following SVA repair increases the risk of reoperation, which decreases the long-term survival. Thus, identifying the risk factors for postoperative AR progression is of great significance.METHODS:Adult patients who were diagnosed with ruptured SVA and underwent surgical repair at the current centre were reviewed. Necessary data in the institutional database were extracted. The perioperative and follow-up assessments of the aortic valve by transthoracic echocardiography were also obtained. The aortic regurgitation progression was grouped into three categories: newly developing, recurrence, and worsening. Sixteen (16) variables were screened to identify potential risk factors by univariate logistic regression analysis or Chi-squared test. Variables with p-values <0.1 were further analysed by multivariate logistic regression models to find independent risk factors.RESULTS:A total of 198 consecutive patients from June 2006 to January 2018 were included. The overall incidence of postoperative AR progression was 19.2% (38 of 198). After the univariate analysis, SVA originating from the right coronary sinus, coexisting with ventricular septal defect, larger diameter of aortic annulus, and larger cardiothoracic ratio were screened as potential risk factors. Multivariate analysis indicated that coexisting with a ventricular septal defect (VSD) (OR, 2.82; 95% CI, 1.217-6.532; p=0.016) and larger cardiothoracic ratio (OR, 1.061; 95% CI, 1.001-1.124; p=0.047) were independent risk factors for postoperative AR progression.CONCLUSIONS:To prevent postoperative AR progression after surgical repair, more careful inspection and appropriate surgical techniques are necessary for patients coexisting with VSD or with a larger cardiothoracic ratio.
Heart, lung & circulation 2022
OBJECTIVES:This study was conducted to investigate whether percutaneous closure of ruptured sinus of Valsalva aneurysm (SVA) is as safe and effective as surgery repair.BACKGROUND:Percutaneous closure of ruptured SVA has been becoming an alternative to the traditional surgical repair recently. The reports regarding direct comparison of these two treatment options are scarce.METHODS:The medical records from the institutional database were retrospectively analyzed. A total of 134 patients were reviewed, including 26 patients undergoing percutaneous closure and 108 patients being treated surgically. To reduce the potential bias, 32 patients from Surgical Repair group were selected by propensity score matching.RESULTS:All the ruptured SVAs were successfully closed in each group. No severe procedure-related complications were found in the perioperative period. After matching, there were no significant differences in the baseline clinical characteristics. The median postoperative hospital stays of Matched group were significantly longer than that of Percutaneous Closure group (7 days vs. 1 day, p < .001). Aortic regurgitation, residual shunt and recurrence of SVAs were common complications in both Percutaneous Closure group and Surgical Repair group.CONCLUSIONS:The appropriately selected patients with ruptured SVA could be treated by percutaneous closure with an acceptable risk of short-term complications. Though surgical repair remains the main treatment option for ruptured SVAs, percutaneous closure could be considered in patients with a small-size rupture and no associated cardiac abnormalities.
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2021
OBJECTIVE:Many countries are facing a shortage of cardiac surgeons, who are crucial in meeting the demands of growing number of patients in need of coronary artery bypass grafting. This situation poses a serious challenge, especially in China. The purpose of this study is to determine whether cardiac surgeons are suitable for training in coronary artery anastomosis at an earlier stage in their career.METHODS:We divided 12 cardiac surgeons with no prior experience in coronary artery anastomosis into senior and junior groups for training and assessment. All trainees received training in coronary artery anastomosis for a defined period. We performed in vivo and in vitro examinations before and after training, respectively. Additionally, we assessed individual surgical performance of surgeons by using performance rating scores, including different aspects of surgical skills rated on a five-point scale.RESULTS:The post-training scores (overall, junior, senior) were significantly higher than the pre-training scores (overall, junior, and senior). We observed no differences in pre-training and post-training scores between the junior and senior groups.CONCLUSION:Senior surgeons did not had any significant advantages over junior surgeons with respect to coronary artery anastomosis in the absence of training. Junior surgeons achieved the same results as the senior surgeons after training.
Anatolian journal of cardiology 2020
BACKGROUND:Cardiopulmonary bypass is the basis of open heart surgery. Through simulation-based learning, residents may receive structured training of cardiopulmonary bypass techniques. Therefore, we built a high-fidelity, tissue-based simulation model for cardiopulmonary bypass cannulation/decannulation training.METHODS:The core of the model is a whole block of cadaveric animal heart and lung. The discarded membrane oxygenators are used as blood reservoirs. The tubing and suckers recycled from animal experiments are washed and reused. To set up the model, the cadaveric heart and lung are placed into a container of appropriate size. The "arterial" tubing is connected with a pressure gauge, the distal aorta, the superior vena cava, and arterial cannula, respectively. The "venous" tubing is composed of three independent catheters, respectively, for the practice of venous cannulation, for the connection of sucker and for the practice of placing left atrial/ventricular vent. All tubes are installed on the roller pumps to maintain the correct flow direction. A technician should be responsible for operating the heart-lung machine, clamping and releasing the specific segments of tubing, adjusting the pressure, and cooperating with the trainees to practice.RESULTS:Using the simulation model, 18 residents underwent cardiopulmonary bypass techniques training, with an average satisfaction of 8.94 points. The mean score on the overall fidelity of the simulation model assessed by nine experienced cardiothoracic surgeons was 8.67 points.CONCLUSION:The tissue-based simulation model has a certain degree of realism. Cardiac surgery residents can practice necessary cardiopulmonary bypass cannulation/decannulation techniques by this model.
Perfusion 2020
SIRT1 (silent information regulator 1) is a histone deacetylase. It can sense the energy level in cells and delay cell senescence, leading to resistance to external stress and improving metabolism. Mitral regurgitation (MR) is a common disease in cardiac surgery. However, there are no previous studies on SIRT1 and left atrial fibrosis caused by MR. In this study, we aimed to explore the regulatory effect of SIRT1 on left atrial fibrosis induced by MR. We used Guizhou miniature pigs to establish an MR model and a sham operation model after anaesthesia induction and respiratory intubation, and these model animals were followed for 30 months after the surgery. The differential distribution and expression of SIRT1 and collagen I in the left atrium was determined by immunofluorescence and Western blotting. Furthermore, we treated NIH3T3 fibroblasts (CFs) with resveratrol and Angiotensin II (Ang II) to analyse the specific mechanism involved in the development of myocardial fibrosis. The results showed that the MR model was successfully constructed. There were 8 pigs in the MR group and 6 pigs in the control group. In both the animal experiments and the cell experiments, the expression of collagen I in the MR group was increased significantly compared to that in the control group, while the expression of SIRT1 was decreased.
Scientific reports 2020
PURPOSE:To investigate the hemodynamics characteristics of the "no-touch" saphenous vein graft (SVG) conduits by nicardipine intraluminal administration in vivo experiment.METHODS:A total of 59 consecutive patients were enrolled and underwent a sequential SVG to three non-left anterior descending (LAD) targets with the average runoff ≤2 mm, 30 with "no-touch" harvest technique (group A) and 29 with conventional preparation (group B). The patients were subject to nicardipine intraluminal injection during off-pump coronary artery bypass grafting (CABG) procedure. The intraoperative flow was measured with the ultrasonic transit time flow meter (TTFM), and the graft patency testified by multi-detector computed tomography (MDCT) angiography, respectively.RESULTS:The baseline blood flow was higher in group A than that in group B (p <0.05). However, the increases in blood flow of SVG conduits in group A were lower than those in group B with 19.7 ± 5.9 vs. 35.4 ± 9.2 mL/min, 14.8 ± 5.6 vs. 23.1 ± 6.8 mL/min, 6.6 ± 2.1 vs. 11.2 ± 4.3 mL/min before the first, second, and third anastomose after nicardipine intraluminal administration, respectively (all p <0.01).CONCLUSIONS:No-touch SVGs were associated with higher baseline blood flow and less rises after nicardipine intraluminal administration during off-pump CABG procedure compared with conventional preparation. The no-touch SVGs seemed to be less spastic and well-tolerated on flow dilatation.
Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia 2020
OBJECTIVE:To investigate the establishment of atrial septal defect model with high success rate in pigs with extracorporeal circulation and the method of followed patch repair.METHODS:Twenty Chinese miniature pigs weighing 45.3-55.7 kg were used, four of which were used for blood donationand the remaining for models. General anesthesia was conducted with intubation. Thoracotomy was performed through the right fourth intercostal space, and the ascending aorta cannulation with a wire-guide technique was carried out. The extra-pericardial method was used for the superior and inferior vena cava cannulation. The ascending aorta was not cross-clamped. After snaring the superior and inferior vena cava, the right atrium was opened on pump. Sutures were preset and a clamp was used to create and expand an interatrial septal hole followed by the implantation of the experimental patch.RESULTS:One animal died due to the aortic root torn and hemorrhage while exposing the right atrial appendage. The remaining 15 pigs successfully completed the operation. Among these 15 experimental animals, one had postoperative hypotension. The average pressure was decreased to 38 mmHg (1 mmHg=0.133 kPa), which was corrected by vasoactive agents and fluid resuscitation. One animal had intraoperative cardiac arrest and was resuscitated by heart massage. Fifteen experimental animals were raised for 6 months and all survived.CONCLUSION:The selection of suitable experimental animals like swine and well-established surgical methods could ensure the success establishment of experimental models and patch repairment.
Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition 2020
OBJECTIVES:The present study was performed to evaluate the feasibility and safety of the ValveClamp system for transcatheter edge-to-edge mitral valve repair in a porcine model.BACKGROUND:The ValveClamp system is a novel, transapically delivered edge-to-edge mitral valve repair system designed for ease of operation.METHODS:Thirteen young adult swine were enrolled in the study. The procedure was performed via the transapical approach under epicardial echocardiography guidance.RESULTS:The acute procedure success rate was 92.3% (12/13). The catheter manipulation time was just 18.5 ± 8.2 min. Four pigs were explanted on the 14th day after the procedure. One pig died at the 20th day because of pneumonia. The other eight pigs lived to the study endpoint (140 days). No pig had severe mitral valve dysfunction. The gross observation showed that the clamp device was securely attached and created a double-orifice mitral valve in all pigs except the failed one. In the eight pigs living to the endpoint, the clamp device was noted to be completely endothelialized. None of the 13 pigs developed infective endocarditis, thrombosis, thromboembolism, or valve impairment. In two pigs for which mitral regurgitation (MR) was created, the degree of MR was reduced from severe to trace after the device implantation.CONCLUSIONS:It was feasible and safe to use ValveClamp to perform a catheter-mediated edge-to-edge mitral valve repair in a porcine model. This system is potentially applicable as a novel user-friendly system for the treatment of MR.
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2019
Pulmonary arterial hypertension (PAH) is a chronic and severe cardiopulmonary disorder. Mice are a popular animal model used to mimic this disease. However, the evaluation of right ventricular pressure (RVP) and pulmonary artery pressure (PAP) remains technically challenging in mice. RVP and PAP are more difficult to measure than left ventricular pressure because of the anatomical differences between the left and right heart systems. In this paper, we describe a stable right heart hemodynamic measurement method and its validation using healthy and PAH mice. This method is based on open-chest surgery and mechanical ventilation support. It is a complicated procedure compared to closed chest procedures. While a well-trained surgeon is required for this surgery, the advantage of this procedure is that it can generate both RVP and PAP parameters at the same time, so it is a preferable procedure for the evaluation of PAH models.
Journal of visualized experiments : JoVE 2019