Progression of Device-Detected Atrial High-Rate Episodes and the Risk of All-Cause Mortality.

Atrial high-rate episodes (AHREs) are prevalent in approximately 1/3 of patients with cardiac implanted electronic devices and are associated with an increased risk of several adverse outcomes. This study aimed to explore the factors associated with AHRE progression and the risk of all-cause mortality. At least 1 day with AHRE burden ≥15 minutes was identified in 124 of 343 recipients (36.2%) of an implantable cardioverter defibrillator or cardiac resynchronization therapy device. We included patients whose AHRE burden at the time of first detection was ≥15 minutes but <24 hours (n = 107). Various cut-off values (15 minutes, 6 hours, and 24 hours) of daily AHRE burden were analyzed. During an average follow-up of 4.2 years, 60 patients (56.1%) experienced ≥1 progression to greater AHRE burden. Patients with hypertension or greater AHRE burden at first detection were associated with faster progression. In addition, 27 deaths (45%) occurred among 60 patients with AHRE progression, compared with 25.5% (12 of 47) for those without progression. After multivariable adjustment, AHRE progression was independently associated with all-cause mortality (hazard ratio 2.56, 95% confidence interval 1.23 to 5.35, p = 0.012). Notably, AHRE progression within 1 month after their first detection was associated with an increased risk for all-cause mortality (hazard ratio 4.01, 95% confidence interval 1.76 to 9.16, p = 0.001) compared with patients without progression. However, a similar risk was not observed among patients with AHRE progression occurring after 1 month after their first detection. In conclusion, >1/2 of the patients with AHRE progressed to a greater burden over time. Continuous monitoring of the AHRE burden may help identify patients at great risk for death.

2.8
3区

The American journal of cardiology 2023

Association between nighttime heart rate and cardiovascular mortality in patients with implantable cardioverter-defibrillator: A cohort study.

BACKGROUND:Although studies have shown that an increased resting heart rate measured randomly at a single point of the day has been associated with adverse cardiovascular outcomes, the utility of continuous monitoring of nighttime heart rate (NTHR) has remained largely uninvestigated.OBJECTIVE:This study aimed to explore the association between NTHR and cardiovascular mortality.METHODS:The Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device-implanted Patients, which is a prospective cohort study, enrolled patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator between 2010 and 2015. Baseline NTHR was measured during the programmed sleep period from 30 to 60 days after implantation. The primary outcome was cardiovascular mortality, fitted by a restricted cubic spline function.RESULTS:A total of 534 implantable cardioverter-defibrillator recipients with sinus rhythm during the detection window were included in the study. The mean baseline NTHR was 59.6 ± 8.0 beats/min. During the follow-up period of 60.4 ± 21.8 months, 88 (16.5%) patients experienced cardiovascular mortality. After considering potential confounders, a linear association was observed. Each 1 beat/min increase in NTHR was associated with a 7.8%, 10.1%, and 5.7% increase in the risk of cardiovascular mortality in the total population, patients with heart failure, and patients without heart failure, respectively.CONCLUSION:Continuous monitoring of NTHR may identify patients at high risk of cardiovascular mortality in a timely manner, with the potential for "preemptive" action.TRIAL REGISTRATION:No. ChiCTR-ONRC-13003695.

5.5
2区

Heart rhythm 2023

Comparison of immediate changes of repolarization parameters after left bundle branch area pacing and traditional biventricular pacing in heart failure patients.

6.1
3区

Chinese medical journal 2023

Quantitative analysis reveals influencing factors to facilitate successful anodal-ring capture in left bundle branch pacing.

AIMS:Left bundle branch pacing (LBBP) maintains left ventricular synchrony but induces right ventricular conduction delay (RVCD). Although anodal-ring capture (ARC) during bipolar LBBP improves RVCD, it is not achieved in all patients receiving LBBP. This study aimed to analyze the factors influencing ARC implementation.METHODS AND RESULTS:Patients receiving LBBP with intraoperative ARC testing were enrolled. Electrocardiographic parameters were measured, including stimulus-to-QRS duration (stim-QRSd), stimulus-to-left/right ventricular activation time (stim-LVAT/RVAT), and V6-V1 interpeak interval. The distribution of lead-tip sites was described as the corrected longitudinal and lateral distance (longit-/lat-dist). Relative angles of the LBBP lead were measured. Echocardiography in short-axis view was used to measure the intraseptal lead length. Intergroup comparisons, correlation analysis, and stepwise logistic regression were performed. In total, 105 patients were included, among which 65 (62%) patients achieved ARC at a pacing output ≤ 5.0 V/0.5 ms (average 3.1 V/0.5 ms). Anodal-ring capture further shortened the stim-QRSd by 13.1 ± 7.5 ms. Better unipolar-ring (cathodal) threshold and R-wave sensing in LBBP-ARC group indicated the critical role of ring-septum contact in ARC. Longer corrected longit-dist and shorter corrected lat-dist of lead-tip sites were positively correlated with higher success likelihood of ARC, likely due to the greater relative angle in which the lead enters the septum and consequently the longer intraseptal lead length and better ring-septum contact.CONCLUSION:This study elucidated the factors affecting the success likelihood of LBBP-ARC. These findings improve the understanding of LBBP-ARC, providing references for future research and clinical practice.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2023

Distance between the lead-implanted site and tricuspid valve annulus in patients with left bundle branch pacing: Effects on postoperative tricuspid regurgitation deterioration.

BACKGROUND:Left bundle branch pacing (LBBP) is an alternative strategy for His-bundle pacing (HBP); however, little is known about tricuspid regurgitation (TR) deterioration after LBBP implantation.OBJECTIVES:The purpose of this study was to characterize the incidence of post-LBBP TR deterioration and identify predicting factors, especially lead position parameters.METHODS:Patients who received LBBP were continuously enrolled from January 2018 to August 2020. The progression of TR and the anatomic position of LBBP were characterized by echocardiography.RESULTS:A total of 89 patients were enrolled and assigned to 2 subgroups based on the degree of TR before LBBP implantation: 58 (65.2%) with relatively normal tricuspid valve (TV) function (grade 0/1 subgroup: with none/trivial or mild TR) and 31 (34.8%) with more severe TR (grade 2/3 subgroup: with moderate or severe TR). At 19.0 ± 6.5 months of follow-up, 29 patients (32.6%) had TR deterioration, and 23 of them were in the grade 0/1 subgroup. In the grade 0/1 subgroup, patients with TR deterioration had a shorter distance between the lead-implanted site and TV (Lead-TA-dist) than those without TR (19.0 ± 7.6 vs 23.9 ± 5.4; P = .006). The receiver operating characteristic (ROC) curve (area under the curve 0.721; 95% confidence interval [CI] 0.575-0.867; P = .005) indicated the favorable efficacy of Lead-TA-dist for predicting TR deterioration after LBBP. Lead-TA-dist ≤16.1 mm was independently associated with TR deterioration after LBBP (hazard ratio 0.20; 95% CI 0.06-0.76; P = .017).CONCLUSION:TR was a common complication of LBBP implantation. In patients with none/trivial or mild TR, Lead-TA-dist ≤16.1 mm was an independent predictor of TR deterioration after LBBP implantation.

5.5
2区

Heart rhythm 2023

The variability and burden of severe sleep apnea and the relationship with atrial fibrillation occurrence: analysis of pacemaker-detected sleep apnea.

STUDY OBJECTIVES:This was a pilot study to evaluate the long-term variability and burden of respiratory disturbance index (RDI) detected by pacemaker and to investigate the relationship between RDI and atrial fibrillation (AF) event in patients with pacemakers.METHODS:This was a prospective study enrolling patients implanted with a pacemaker that could calculate the night-to-night RDI. The mean follow-up was 348 ± 34 days. The RDI variability was defined as the standard deviation of RDI (RDI-SD). RDI burden was referred to as the percentage of nights with RDI ≥ 26. The patient with RDI ≥ 26 in more than 75% nights was considered to have a high sleep apnea (SA) burden. An AF event was defined as a daily AF duration > 6 h.RESULTS:Among 30 patients, the mean RDI of the whole follow-up period was 24.5 ± 8.6. Nine (30%) patients were diagnosed with high SA burden. Patients with high SA burden had a higher BMI (26.7 ± 4.8 vs 23.2 ± 3.9, p = 0.036), a higher prevalence of hypertension (86% vs 39%, p = 0.031), and a larger left ventricular diastolic diameter (49.2 mm vs 46.7 mm, p = 0.036). The RDI-SD in patients with a higher burden was significantly greater than that in the patients with less burden (10.7 ± 4.9 vs 5.7 ± 1.4, p = 0.036). Linear regression showed that participants with a higher RDI tended to have a higher SD (R = 0.661; p < 0.001). The mean RDI (OR = 1.118, 95%CI 1.008-1.244, p = 0.044) was associated with AF occurrence.CONCLUSION:Using a metric such as burden of severe SA may be more appropriate to demonstrate a patient's true disease burden.

2.5
4区
第一作者

Sleep & breathing = Schlaf & Atmung 2022

Changes of repolarization parameters after left bundle branch area pacing and the association with echocardiographic response in heart failure patients.

Background: Left bundle branch area pacing (LBBAP) has become a safe and effective option for heart failure (HF) patients indicated for cardiac resynchronization therapy (CRT) and/or ventricular pacing, yet the response rate was only 70%. Repolarization parameters were demonstrated to be associated with cardiac mechanics and systolic function. This study aimed to investigate the effects of LBBAP on repolarization parameters and the potential association between those parameters and echocardiographic response. Methods and results: A total of 59 HF patients undergoing successful LBBAP were consecutively included. QTc, Tpeak-Tend (TpTe), and TpTe/QTc were measured before and after the implantation. The results turned out that the dispersion of ventricular repolarization (DVR) improved after LBBAP among the total population. Although trends of repolarization parameters varied according to different QRS configurations at baseline, the post-implant parameters showed no significant difference between groups. The association between repolarization parameters and LBBAP response was then evaluated among patients with wide QRS. Multivariate analysis demonstrated that post-implant TpTe was the independent predictor of LBBAP response (p < 0.05). Receiver operating characteristic analysis indicated an area under the curve of 0.77 (95% CI, 0.60-0.93) with a cutoff value of 81.2 ms (p < 0.01). Patients with post-implant TpTe<81.2 ms had a significantly higher rate of echocardiographic response (93.3 vs. 44.4%, p < 0.01). Further subgroup analysis indicated that the predictive value of post-implant TpTe for LBBAP response was more significant in non-left bundle branch block (LBBB) patients than in LBBB patients. Conclusion: LBBAP improved DVR significantly in HF patients. Post-implant TpTe was associated with the echocardiographic response after LBBAP among patients with wide QRS, especially for non-LBBB patients.

4.0
3区

Frontiers in physiology 2022

Long-term follow-up results of patients with left bundle branch pacing and exploration for potential factors affecting cardiac function.

Background: Left bundle branch pacing (LBBP) is an alternative strategy for His bundle pacing (HBP). This study aimed to analyze the long-term performance of LBBP and the potential factors affecting long-term cardiac function. Methods: Patients with LBBP were continuously enrolled from January 2018 to August 2020. Pacing parameters, electrocardiogram (ECG), and echocardiography were collected. The anatomic position of LBBP leads was described by echocardiographic and fluoroscopic parameters. Results: A total of 91 patients with a median follow-up of 18 months were enrolled. Most patients maintained stable pacing parameters during follow-up. The intra-septal position of the 3830 lead also remained stable as the distance from the lead tip to the left surface of the ventricular septum was 0.4 (0, 1.4) mm. The overall level of left ventricular ejection fraction (LVEF) slightly increased. 59 patients had improved LVEF (∆LVEF > 0), while 28 patients had unchanged or reduced LVEF (∆LVEF ≤ 0). The declines of baseline LVEF, ∆ Paced QRSd, and corrected longitudinal distance (longit-dist) of lead-implanted site correlated with LVEF improvement, and these three factors had negative linear correlations with ∆LVEF. Patients with tricuspid valve regurgitation (TVR) deterioration had longer follow-up duration (20.5 vs. 15.0 months, p = 0.01) and shorter Lead-TVA-dist (18.6 vs. 21.6 mm, p = 0.04) than those without TVR deterioration. Conclusion: Patients with LBBP generally remained stable in pacing performance, anatomic lead positions, and cardiac function in long-term follow-up. Baseline LVEF, ∆ Paced QRSd, and corrected longit-dist might be associated with potential LVEF decrease, which required further confirmation.

4.0
3区

Frontiers in physiology 2022

Quantitative distance and electrocardiographic parameters for lead-implanted site selection to enhance the success likelihood of left bundle branch pacing.

BACKGROUND:Left bundle branch pacing (LBBP) is a novel near-physiological pacing method that still lacks quantitative criteria to guide the selection of lead-implanted sites to enhance the success likelihood of lead deployments. This study aimed to quantitatively analyze the relationships of LBBP success likelihood to the distribution of lead-implanted sites and the lead-localization-pacing electrocardiographic (ECG) features.METHODS:All the lead-implanted sites in patients with finally successful LBBP were enrolled for analysis, including successful and failed sites. A novel coordinate system was invented to describe the sites' distribution as longitudinal distance (longit-dist) and lateral distance (lat-dist). Corrected distance parameters were generated to eliminate the cardiac dimension variations. The lead-localization-pacing ECG parameters were also collected, such as paced QRS duration (locat-QRSd), left ventricular activation time (locat-LVAT), LVAT/QRSd ratio (locat-LVAT/QRSd), and QRS directions.RESULTS:A total of 94 patients with 105 successful sites and 93 failed sites were enrolled. Longit-dist and corrected longit-dist of successful sites were significantly longer, while locat-QRSd and locat-LVAT were shorter and locat-LVAT/QRSd was lower than failed sites. There was a positive dose-response relationship between LBBP success likelihood and corrected longit-dist with a cut-off of 26.95 mm, whereas there were negative dose-response relationships of LBBP success likelihood to locat-QRSd, locat-LVAT, and locat-LVAT/QRSd with the cut-offs of 142 ms, 92 ms, and 64.7%, respectively. Downward QRS direction in II/III ECG leads was also associated with successful LBBP.CONCLUSION:Longit-dist, locat-QRSd, locat-LVAT, and locat-LVAT/QRSd were quantitative parameters to guide the selection of lead-implanted sites during LBBP implantation. Quantitative distance and electrocardiographic parameters for lead-implanted site selection to enhance the success likelihood of left bundle branch pacing. LBBP, left bundle branch pacing; Longit-dist, longitudinal distance; CL-apex-dist, distance from contraction line to apex; LBBB, left bundle branch block; IVCD, intraventricular conduction delay; Locat-QRSd, lead-localization-pacing QRS duration; Locat-LVAT, lead-localization-pacing left ventricular activation time; Locat-LVAT/QRSd, lead-localization-pacing LVAT/QRSd ratio.

5.0
2区

Clinical research in cardiology : official journal of the German Cardiac Society 2022

Relationship of paced left bundle branch pacing morphology with anatomic location and physiological outcomes.

BACKGROUND:Left bundle branch pacing (LBBP) is an emerging physiological pacing modality. However, little is known about pacing at different locations on the left bundle branch (LBB).OBJECTIVE:The purpose of this study was to explore pacing and physiological characteristics associated with different LBBP locations.METHODS:The study included 68 consecutive patients with normal unpaced QRS duration and successful LBBP implantation. Patients were divided into 3 groups according to the paced QRS complex as left bundle branch trunk pacing (LBTP), left posterior fascicular pacing (LPFP), or left anterior fascicular pacing (LAFP). Electrocardiographic (ECG) characteristics, pacing parameters, and fluoroscopic localization were collected and analyzed.RESULTS:There were 17 (25.0%), 35 (51.5%), and 16 (23.5%) patients in the LBTP, LPFP, and LAFP groups, respectively. All subgroups had relatively narrow paced QRS complex (128.6 ± 9.1 ms vs 133.7 ± 11.2 ms vs 134.8 ± 9.6 ms; P = .170), fast left ventricular activation (70.4 ± 9.0 ms vs 70.6 ± 10.2 ms vs 71.0 ± 9.0 ms; P = .986), as well as low and stable pacing thresholds. Delayed right ventricular activation and interventricular dyssynchrony were similar between groups. Fluoroscopic imaging indicated that the lead tip was located most commonly in the basal-middle region of the septum (67.7%), and this was independent of paced QRS morphology group (88.2% vs 57.1% vs 68.8%; P = .106).CONCLUSION:Pacing at different sites of the LBB resulted in similar intraventricular and interventricular electrical synchrony in patients with an intact conduction system. Fluoroscopic imaging alone could not predict specific LBBP paced ECG morphology.

5.5
2区

Heart rhythm 2021