乔恩
中国医学科学院阜外医院 结构性心脏病中心53病区
Either a mechanical or bioprosthetic valve is used in patients undergoing mitral valve replacement (MVR). However, the optimal mitral prosthesis remains controversial. The aim of this meta-analysis was thus to compare outcomes between mechanical mitral valve replacement (MVRm) and bioprosthetic mitral valve replacement (MVRb) for MVR patients. We searched Embase, PubMed, Web of Science, and Cochrane Library databases from January 1, 2000 to October 31, 2021 for studies that directly compared surgical outcomes of MVRm and MVRb. A total of 22 studies with 35 903 patients were included in the meta-analysis (n = 23 868 MVRm and n = 12 035 MVRb). The MVRm group displayed lower long-term all causes mortality (HR, 0.84; 95% confidence interval [CI]: 0.77-0.91; p < .0001; I² = 51%), and fewer mitral reoperation (hazard ratio [HR]: 0.34; 95% CI: 0.23-0.50; p < .00001; I² = 74%) than MVRb group. However, the MVRm group was associated with a greater risk of major bleeding events (HR: 1.21; 95% CI: 1.14-1.29; p < .00001; I² = 0%), stroke and systemic embolism (HR: 1.20; 95% CI: 1.10-1.32; p < .0001; I² = 0%) in matched or adjusted data. No significant difference was observed between MVRm and MVRb on operative mortality in matched/adjusted group (risk ratios: 0.83; 95% CI: 0.66-1.05; p = .12; I² = 0%). The results were consistent with patients aged under 70 years old. Patients who received a MVRm is associated with 16% lower risk of long-term mortality and 66% lower risk of mitral reoperation, but 20% greater risk of stroke or systemic embolism, 21% greater risk of major bleeding compared with MVRb in matched/adjusted studies group, which were consistent to patients younger than the age of 70 years who underwent MVR.
Clinical cardiology 2022
Calcific aortic valve disease (CAVD) is currently the most prevalent valvular disease. However, the pathological mechanism of CAVD has not yet been fully elucidated, and no drugs can delay or halt the progression of CAVD. This study aimed to screen for potential biomarkers and pathways of CAVD through bioinformatics analysis. The identification of differentially expressed genes (DEGs) between calcific aortic valves and the control group was performed based on four microarray datasets: GSE12644, GSE51472, GSE77287 and GSE83453. Gene Ontology and Kyoto Encyclopaedia of Genes and Genomes (KEGG) pathway enrichment analysis were conducted. Furthermore, the protein-protein interaction network, and microRNA-target interaction was performed, and hub genes were obtained by using twelve cytoHubba algorithms. As a result, 327 DEGs were identified, including 206 up-regulated and 121 down-regulated genes. KEGG analysis showed that these DEGs were mainly enriched in the PI3K-AKT signaling pathway, ECM-receptor interaction, cytokine-cytokine receptor interaction, and chemokine signaling pathway etc. Moreover, we identified 19 hub genes: CXCL8, CXCL12, CSF1R, HCK, PLEK, CCL5, TLR8, VCAM1, CCR1, CCR7, FPR1, TYROBP, CX3CR1, KIT, PPBP, SPP1, SYK, TLR7, and VWF. And multiple potential miRNAs, including miR-141, miR-34a, miR-155, and miR-486, were identified. And western blot was performed to validate the expression level of hub genes. In conclusion, this study identified several promising biomarkers and pathways for CAVD, which may provide novel molecular markers for diagnosis and targeted therapy.
Gene 2022
This study aimed to assess the relationship between local mechanical stimuli and regional aortic tissue degeneration using fluid-structure interaction (FSI) analysis in patients with bicuspid aortic valve (BAV) disease. Nine patients underwent ascending aortic replacement were recruited. Tissues were collected to evaluate the pathology features in four regions, greater curvature (GC-region), posterior (P-region), anterior (A-region), and lesser curvature (LC-region). FSI analysis was performed to quantify vessel structural stress (VSS) and flow-induced parameters, including wall shear stress (WSS), oscillatory shear index (OSI), and particle relative residence time (RRT). The correlation between these biomechanical metrics and tissue degeneration was analyzed. Elastin in the medial layer and media thickness were thinnest and the gap between fibers was biggest in the GC-region, followed by the P-region and A-region, while the elastin and media thickness were thickest and the gap smallest in the LC-region. The collagen deposition followed a pattern with the biggest in the GC-region and least in the LC-region. There is a strong negative correlation between mean or peak VSS and elastin thickness in the arterial wall in the GC-region (r = -0.917; p = 0.001 and r = -0.899; p = 0.001), A-region (r = -0.748; p = 0.020 and r = -0.700; p = 0.036) and P-region (r = -0.773; p = 0.014 and r = -0.769; p = 0.015), and between mean VSS and fiber distance in the A-region (r = -0.702, p = 0.035). Moreover, strong negative correlation between mean or peak VSS and media thickness was also observed. No correlation was found between WSS, OSI, and RRT and aortic tissue degeneration in these four regions. These findings indicate that increased VSS correlated with local elastin degradation and aortic media degeneration, implying that it could be a potential biomechanical parameter for a refined risk stratification for patients with BAV.
Journal of biomechanics 2021
BACKGROUND:The clinical use of the radial artery (RA) in coronary artery bypass grafting (CABG) is still limited worldwide, although it has been recommended by several guidelines. Multidetector computed tomography (MDCT) is widely used to evaluate graft patency, as invasive coronary angiography could cause potentially serious risks including bleeding, dissection and stroke. This study aims to report the short-term results of the RA in CABG with MDCT.METHODS:The study population consists of 41 consecutive patients undergoing elective CABG with the RA graft between 2017 to 2018, with MDCT performed to evaluate graft patency during follow-up, and target vessels for the RA were non-left anterior descending coronary arteries with > 70% stenosis.RESULTS:A total of 150 grafts were assessed by MDCT during follow-up (mean, 8.9 ± 5.1 months). MDCT could clearly show the structure and patency of grafts, even for complex coronary artery revascularization. Graft patency of the left internal mammary artery was 92.9% (39/42), with the RA patency of 84.4% (38/45) and the patency of the saphenous vein graft of 81.1% (30/37). And the RA anastomosed to the left coronary artery system might have better patency than the RA anastomosed to the right coronary artery system (25/29, 86.2% vs 13/16, 81.3%, p = 0.686).CONCLUSIONS:The short-term patency rate of RA grafts is good, and the RA might be associated with better patency when anastomosed to the left but not the right coronary artery. MDCT could provide excellent visualization of grafts in CABG.
Journal of cardiothoracic surgery 2021
This study assesses the long-term outcomes of patients who suffered from self-expandable transcatheter heart valve (THV) embolized in the aorta in transcatheter aortic valve implantation (TAVI).We retrospectively reviewed the patients with self-expandable THV embolized in the aorta. Follow-up computed tomography was performed to assess the THV migration, struct fractures, and device-related aortic complications.Of the 539 TAVI patients, 11 suffered from self-expandable THV embolized in the aorta. Two patients underwent open-heart surgery to remove the embolized THVs in the ascending aorta. Embolized THVs were repositioned in the aortic arch distal to the left subclavian artery (n = 3) and the thoracic descending aorta (n = 6). Three patients died during a median follow-up time of 40 months. The remaining eight survivors presented with New York Heart Association functional class I or II at the last follow-up. Degeneration of embolized prostheses with thick leaflets and rolled cusp edges was observed in three patients. There was no evidence of valve migration, strut fracture, prosthesis-associated aortic complication, and thrombosis attached on embolized valve for all patients with THVs repositioned in the aorta.Self-expandable THV embolization can be effectively managed in TAVI. Although some embolized valves exhibited leaflet degeneration, the long-term safety of repositioning embolized self-expandable THV in the aorta is assured.
International heart journal 2021
INTRODUCTION:Primary benign right ventricular tumours are rare. They can cause significant mortality without appropriate and timely treatment. We investigated surgical treatment and survival characteristics for right ventricular tumours.MATERIALS AND METHODS:From 2007 to 2017, 21 patients with primary benign right ventricular tumours who underwent tumour resection were retrospectively reviewed. Clinical findings and follow-up results were analysed.RESULTS:Thirteen men and eight women were enrolled, with a mean age of 42.3 ± 15.3 years. The most frequent histotypes were myxoma, haemangioma and papillary fibroelastoma. Eight patients underwent concomitant tricuspid valvuloplasty and one had tricuspid valve replacement. No major adverse events or death occurred during the perioperative period. One patient with haemangioma underwent partial tumour resection; however, the tumour regressed gradually during follow-up. Within the 10-year follow-up period (mean 4.8 ± 2.6 years), the recurrence-free and overall survival rates were 81.0% and 85.7%, respectively.CONCLUSIONS:Tumour resection for primary benign right ventricular tumours is safe and effective, and has a good prognosis. Tricuspid valvuloplasty or tricuspid valve replacement may be necessary for the resection of right ventricular tumours to improve the haemodynamics. Haemangiomas naturally undergo spontaneous regression.
Annals of the Royal College of Surgeons of England 2021
PURPOSE:The dilation of proximal arch (PArc) was suspected to develop as a result of valve-related hemodynamics or in consequence to the upward extension of the ascending aorta (AAo) dilation. We aimed to investigate the one that could be the possible contributing factor in patients with bicuspid aortic valve (BAV).METHODS:All enrolled BAV patients underwent four-dimensional flow magnetic resonance imaging. Contour-averaged circumferential wall shear stress (WSScirc,avg) and the diameter of the middle of AAo (mid-AAo) were compared between the patients with and without PArc dilation. Additionally, we analyzed the correlation between WSScirc,avg and aortic diameter at PArc section, as well as the correlation between the diameter of mid-AAo and that of PArc.RESULTS:No significant difference was observed in WSScirc,avg at PArc section between the patients with and without PArc dilation (P = .621). However, the diameter of mid-AAo in the patients who suffered PArc dilation was higher than those without it (P = .007). In addition, the aortic diameter did not correlate with the WSScirc,avg at PArc level (R = -0.068, P = .701). The correlation was observed between PArc diameter and mid-AAo diameter (R = 0.521, P = .002).CONCLUSION:Hemodynamics may not contribute to the development of PArc dilation. PArc diameter correlated with mid-AAo diameter, indicating PArc dilation may be secondary to the upward extension of AAo dilation. The influence of AAo dilation extending upward could be treated by AAo replacement; hence, a selective approach to transverse PArc replacement might be appropriate.
The heart surgery forum 2020