葛怡

中国医学科学院阜外医院 阜外心血管病医院28病区

Echocardiographic Guided Closure of Perimembranous Ventricular Septal Defects.

BACKGROUND:Transesophageal echocardiogram-guided minimally invasive periventricular device closure of perimembranous ventricular septal defects (pmVSDs) without cardiopulmonary bypass is a treatment option for pmVSDs. We introduce our improvements to this technique and mid-term follow-up results.METHODS:From May 2011 to May 2014, 187 patients with pmVSDs aged 6 months to 31 years (8.2 ± 10.2 years) were enrolled in this study. The procedure was performed through a new transthoracic approach of 1 to 2 cm without sternotomy. Device selection and the operative procedure were monitored by transesophageal echocardiogram. The patients underwent follow-up examinations of echocardiography and electrocardiogram at 1 month, 3 months, 6 months, and 1 year after the operation and annually thereafter.RESULTS:The defects were closed successfully in 179 patients (95.7%), and in 8 patients the operation was converted to conventional surgical repair. Six patients (3.4%) had an incomplete right bundle branch block. One patient experienced an intermittent complete atrioventricular block on the fourth day after the operation, and sinus rhythm was restored by corticosteroid therapy after 5 days. A trivial residual shunt was observed in 8 patients (4.5%) during the procedure. The average hospital stay was 3.1 ± 0.9 days. Follow-up in all patients ranged from 1 month to 36 months (median, 12.6 months), and aortic regurgitation, malignant arrhythmia, and device dislocation were not observed in any patients. However, 3 patients (1.7%) still had a trivial residual shunt at their last follow-up.CONCLUSIONS:Periventricular device closure through a modified transthoracic approach without sternotomy is a potentially safe and effective treatment option for pmVSDs. Controlled studies with long-term follow-up are necessary.

4.6
2区

The Annals of thoracic surgery 2015

[Safety and efficacy of percutaneous transcatheter closure of atrial septal defect under transesophageal echocardiography guidance in children].

OBJECTIVE:To assess the safety and effectiveness of percutaneous transcatheter closure of atrial septal defect (ASD) under transesophageal echocardiography (TEE) guidance in children.METHODS:The study included 20 cases of patients with ASD. The patients were (4.2 ± 1.2) years old and the mean body weights were (18.2 ± 4.2) kg. The diameter of ASD before closure was (13.4 ± 3.3) mm . All procedures were guided under TEE. Procedure success was evaluated by TEE immediately after procedure.RESULTS:Closure devices were successfully implanted in all 20 patients under TEE guidance. The diameter of closure devices was 14-26 mm. There were no procedure related complications. The ventilation time was (2.9 ± 0.8)h and the hospitalization time was (3.2 ± 0.7) days.CONCLUSION:TEE guided percutaneous transcatheter closure is safe and effective for patients with ASD and avoids the radiation damages.

Zhonghua xin xue guan bing za zhi 2013