卫淑芳

河南省人民医院 放射科

Value of 3.0T MRI T2 mapping combined with SWI for the assessment of early lesions in hemophilic arthropathy.

PURPOSE:To explore the value of magnetic resonance imaging (MRI) T2 mapping combined with susceptibility-weighted imaging (SWI) in detecting early cartilage damage and joint bleeding in the hemophilic arthropathy (HA).METHODS:147 patients and 56 healthy controls were prospectively recruited. The knees were divided into groups A and B according to the criteria of the International Cartilage Repair Society (ICRS). The Regions of Interest (ROIs) of T2 mapping were drawn for the patella, lateral and medial femoral condyle, and lateral and medial tibial condyle. The T2 values were compared between the patients and control group using one-way ANOVA. The joint count data of International Prophylaxis Study Group (IPSG) scores of conventional and SWI sequences were statistically described using the composition ratio, and the rank sum test was used for the difference analysis.RESULTS:Finally, there were 99 joints in the control group, 135 knees in group A, and 94 knees in group B. There was a significant difference between the T2 value in each subgroup. Comparison of T2 value groups in each cartilage partition, except for group A and group B of the patella, revealed significant differences (all P<0.05). SWI was likely more sensitive than conventional sequences in detecting hemosiderin deposits in hemophilic joints. In addition, the IPSG scores detected by the SWI were generally higher than those of conventional sequences.CONCLUSIONS:MR T2 mapping combined with SWI has great potential to be used for detecting early cartilage damage and micro-hemosiderin deposition in hemophiliac arthropathies and developing preventative treatment plans.

1.9
4区

Hematology (Amsterdam, Netherlands) 2022

High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging.

Background/Aim: The turbo spin-echo (TSE) sequence is widely used for musculoskeletal (MSK) imaging; however, its acquisition speed is limited and can be easily affected by motion artifacts. We aimed to evaluate whether the use of a simultaneous multi-slice TSE (SMS-TSE) sequence can accelerate MSK imaging while maintaining image quality when compared with the routine TSE sequence. Methods: We prospectively enrolled 71 patients [mean age, 37.43 ± 12.56 (range, 20-67) years], including 37 men and 34 women, to undergo TSE and SMS sequences. The total scanning times for the wrist, ankle and knee joint with routine sequence were 14.92, 13.97, and 13.48 min, respectively. For the SMS-TSE sequence, they were 7.52, 7.20, and 6.87 min. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured. Three experienced MSK imaging radiologists qualitatively evaluated the image quality of bone texture, cartilage, tendons, ligament, meniscus, and artifact using a 5-point evaluation system, and the diagnostic performance of the SMS-TSE sequences was evaluated. Results: Compared with the routine TSE sequences, the scanning time was lower by 49.60, 48.46, and 49.04% using SMS-TSE sequences for the wrist, ankle, and knee joints, respectively. For the SNR comparison, the SMS-TSE sequences were significantly higher than the routine TSE sequence for wrist (except for Axial-T2WI-FS), ankle, and knee joint MR imaging (all p < 0.05), but no statistical significance was obtained for the CNR measurement (all p > 0.05, except for Sag-PDWI-FS in ankle joint). For the wrist joint, the diagnostic sensitivity, specificity, and accuracy were 88.24, 100, and 92%. For the ankle joint, they were 100, 75, and 93.33%. For the knee joint, they were 87.50, 85.71, and 87.10%. Conclusion: The use of the SMS-TSE sequence in the wrist, ankle, and knee joints can significantly reduce the scanning time and show similar image quality when compared with the routine TSE sequence.

4.0
3区

Frontiers in physiology 2021

Multislice spiral computed tomography imaging in evaluating hemophilic arthropathy.

BACKGROUND:Certain hemophilia patients are unable to cooperate with or afford magnetic resonance imaging (MRI) examinations. The purpose of our study was to explore the value of multislice spiral computed tomography (MSCT) in evaluating hemophilic arthropathy (HA).METHODS:Thirty-eight patients with 73 joints of HA were consecutively selected from January 2016 to May 2018 for this prospective study. All 73 joints were examined by X-ray, CT, and MRI within 2 days. The MRI scores of the joints were determined by the International Prophylaxis Study Group (IPSG) standard. The CT findings were quantified according to the IPSG standard, except for cartilage injury, which was quantified by joint space narrowing using the X-ray Pettersson score. The CT and MRI scores were compared by the paired Wilcoxon signed-rank test. The correlations between the CT score of joint space narrowing and MRI score of cartilage injury and the total CT and MRI scores were analyzed by Spearman rank correlation. The kappa test was used to compare the consistency of CT and MRI scores.RESULTS:MRI was superior to CT based on the scores for small amount of effusion (P < 0.05), synovial hypertrophy and hemosiderin deposition in the mild groups (P < 0.05). The CT and MRI scores were not significantly different for moderate and massive effusion, synovial hypertrophy, and hemosiderin deposition in the moderate and severe groups, bone erosion or cystic changes (P > 0.05), and there was a high degree of consistency between the two scores (kappa > 0.81). The consistency between the Pettersson scores of joint space narrowing on CT and the IPSG scores of cartilage injury on MRI was high (kappa = 0. 774, P < 0.05).CONCLUSION:The image scores of MSCT are generally consistent with MRI except for mild synovitis, which can be used as an alternative for the evaluation of HA.

6.1
3区

Chinese medical journal 2020