谢涌泉
中国医学科学院阜外医院 结构性心脏病中心
Although the use of bioabsorbable occluder is expected to reduce the risk of metal occluder-related complications, it has not been approved due to incomplete degradation and new complications. Novel fully bioabsorbable occluders were designed to overcome such limitations. The aim of this study was to investigate the efficacy and safety of a fully biodegradable occluder in patients with ventricular septal defects. 125 patients with perimembranous ventricular septal defect (VSD) larger than 3 mm were screened from April 2019 to January 2020 in seven centers. 108 patients were enrolled and randomized into the bioabsorbable occluder group (n = 54 patients) and nitinol occluder group (n = 54). A non-inferiority design was utilized and all patients underwent transcatheter device occlusion. Outcomes were analyzed with a 24-month follow-up. All patients were successfully implanted and completed the trial. No residual shunt >2 mm was observed during follow-up. Transthoracic echocardiography showed a hyperechoic area corresponding to the bioabsorbable occluder which decreased primarily during the first year after implantation and disappeared within 24 months. Postprocedural arrhythmia was the only occluder-related complication with an incidence of 5.56% and 14.81% for the bioabsorbable and nitinol groups, respectively (P = 0.112). The incidence of sustained conduction block was lower in the bioabsorbable occluder group (0/54 vs. 6/54, P = 0.036) at 24-month follow-up. In conclusion, the novel fully bioabsorbable occluder can be successfully and safely implanted under echocardiography guidance and reduce the incidence of sustained postprocedural arrythmia. The efficacy and safety of this fully biodegradable occluder are non-inferior to that of a traditional nitinol one.
Science bulletin 2023
The treatment of myocardial infarction (MI) remains a substantial challenge due to excessive inflammation, massive cell death, and restricted regenerative potential, leading to maladaptive healing process and eventually heart failure. Current strategies of regulating inflammation or improving cardiac tissue regeneration have limited success. Herein, a hybrid hydrogel coassembled by acellular cardiac extracellular matrix (ECM) and immunomodulatory glycopeptide is developed for endogenous tissue regeneration after MI. The hydrogel constructs a niche recapitulating the architecture of native ECM for attracting host cell homing, controlling macrophage differentiation via glycopeptide unit, and promoting endotheliocyte proliferation by enhancing the macrophage-endotheliocyte crosstalk, which coordinate the innate healing mechanism for cardiac tissue regeneration. In a rodent MI model, the hybrid hydrogel successfully orchestrates a proreparative response indicated by enhanced M2 macrophage polarization, increased angiogenesis, and improved cardiomyocyte survival, which alleviates infarct size, improves wall thicknesses, and enhances cardiac contractility. Furthermore, the safety and effectiveness of the hydrogel are demonstrated in a porcine MI model, wherein proteomics verifies the regulation of immune response, proangiogenesis, and accelerated healing process. Collectively, the injectable composite hydrogel serving as an immunomodulatory niche for promoting cell homing and proliferation, inflammation modulation, tissue remodeling, and function restoration provides an effective strategy for endogenous cardiac repair.
Advanced science (Weinheim, Baden-Wurttemberg, Germany) 2023
Ventricular septal defect (VSD) is one of the commonest congenital heart diseases (CHDs). Current occluders for VSD treatment are mainly made of nitinol, which has the risk of nickel allergy, persistent myocardial abrasion and fatal arrythmia. Herein, a fully biodegradable polydioxanone (PDO) occluder equipped with a shape line and poly-l-lactic acid PLLA membranes is developed for VSD closure without the addition of metal marker. PDO occluder showed great mechanical strength, fatigue resistance, geometry fitness, biocompatibility and degradability. In a rat subcutaneous implantation model, PDO filaments significantly alleviated inflammation response, mitigated fibrosis and promoted endothelialization compared with nitinol. The safety and efficacy of PDO occluder were confirmed in a canine VSD model with 3-year follow-up, demonstrating the biodegradable PDO occluder could not only effectively repair VSD, induce cardiac remodeling but also address the complications associated with metal occluders. Furthermore, a pilot clinical trial with five VSD patients indicated that all the occluders were successfully implanted under the guidance of echocardiography and no adverse events occurred during the 3-month follow-up. Collectively, the fully bioresorbable PDO occluder is safe and effective for clinical VSD closure and holds great promise for the treatment of structural CHDs.
Bioactive materials 2023
Background:Balloon-expandable valves (BEV) and self-expanding valves (SEV) for transcatheter aortic valve replacement (TAVR) have shown promising results in Western populations. Herein, we comparatively evaluated their hemodynamics and early clinical outcomes in a Chinese population.Methods:One hundred seventy-eight patients with symptomatic aortic stenosis who had undergone transfemoral TAVR using SEV (n=153; Venus-A, 97; VitaFlow, 56) or BEV (n=25; Sapien3) from September 2020 to April 2021 were retrospectively enrolled, and 25 pairs were propensity-score matched for 10 baseline variables. The primary study outcomes were aortic valve hemodynamics and postoperative complications at discharge and 3-month follow-up.Results:TAVR was successful in all patients. Compared with SEV group, the BEV group had similarly distributed baseline characteristics, procedural time, hospital stay, new pacemaker implantation, and paravalvular regurgitation grade. We also observed that the BEV group had lower rates of balloon pre-dilation (60% vs. 92%, P=0.018), post-dilation (0 vs. 20%, P=0.050) and second valve implantation (0 vs. 24%, P=0.022); higher mean transaortic gradient (14.3±6.1 vs. 10.8±4.9, P=0.030) and proportion of patients with elevated gradients (20% vs. 0, P=0.050) at discharge; and similar rehospitalization, mean transaortic gradient, new pacemaker implantation, and paravalvular regurgitation grade than the SEV group at the 3-month follow-up. There were no deaths in either group. However, the proportion of patients with elevated gradients in SEV group was higher at 3 months than before discharge (24% vs. 0, P=0.022).Conclusions:BEV and SEV for transfemoral TAVR appear comparably safe and effective, with high device success and favorable 3-month clinical outcomes. However, the transaortic gradient and new pacemaker implantation in the SEV group increased during follow-up, warranting larger studies with longer-term follow-up.
Annals of translational medicine 2022
BACKGROUND:Severe mitral regurgitation (MR) is associated with progressive heart failure and impairment of survival. Degenerative MR accounts for most MV repair surgeries. Conventional mitral valve repair surgery requires cardiopulmonary bypass and is associated with significant morbidity and risks. Transapical beating-heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography (TEE) guidance has the potential to significantly reduce surgical morbidity. We report the first-in-human experience of degenerative MR repair using a novel artificial chordae implantation device (MitralstitchTM system).METHODS:Ten patients with severe MR underwent transapical artificial chordae implantation using MitralstitchTM system. The procedure was performed through a small left thoracotomy under general anesthesia and TEE guidance. Patients underwent transthoracic echocardiography and other assessments during the follow-up.RESULTS:All 10 patients with an average age of 63.7 ± 9.6 years successfully received transapical artificial chordae implantation. Their MR reduced from severe to none or trace in five patients, mild in five patients before discharge. Five patients received one artificial chordal implantation, four patients received two, and one patient received three and edge-to-edge repair by locking two of them. The safety and efficacy endpoint were achieved in all patients at 1-month follow-up. At 1-year follow-up, six patients had mild MR, three patients had moderate MR, one patient had recurrence of severe MR and underwent surgical repair.CONCLUSIONS:The results of this first-in-human study show safety and feasibility of transapical mitral valve repair using MitralStitch system. Patient selection and technical refinement are crucial to improve the outcomes.
Journal of cardiac surgery 2022
Endothelial-to-mesenchymal transition (EndMT) plays a critical role in the flow-induced vascular remodeling process, such as pulmonary arterial hypertension (PAH) related to congenital heart disease (CHD). NBL1 (neuroblastoma suppressor of tumorigenicity 1) is a secreted glycoprotein that has been implicated in CHD-PAH by aggravating the phenotypic transformation of smooth muscle cells. However, the underlying mechanisms regarding the interplay between NBL1 and endothelial cells in CHD-PAH remain to be fully elucidated. Thus, we aimed to identify the potential effect of NBL1 on EndMT using a novel flow-associated PAH model with Nbl1 knockout rats. The phenotype of EndMT was detected using RNA sequencing and further examined using western blotting and immunostaining of pulmonary arteries. Our observations demonstrated that the novel strategy of Nbl1 knockout effectively attenuated flow-associated PAH through downregulation of EndMT to some extent. Mechanistic experiments were established on human pulmonary artery endothelial cells to confirm that EndMT was induced by NBL1 in vitro. After 7 days' stimulation with NBL1, concentrations of EndMT-related biomarkers and downstream transcription factors were quantified using RNA sequencing, western blotting, and immunocytochemistry. Both in vitro and in vivo experiments supported the imbalance of increased TGF-β (transforming growth factor-β) and dysregulation of BMP (bone morphogenetic protein) signaling by NBL1. Blocking the canonical TGF-β pathway efficiently preserved endothelial function upon NBL1 stimulation. These data suggested that NBL1 aggravated flow-associated PAH by inducing EndMT via the TGF-β and BMP signaling pathway. Thus, antagonizing NBL1 and rebalancing TGF-β and BMP signaling may be a suitable therapeutic target for CHD-PAH.
American journal of respiratory cell and molecular biology 2022
BACKGROUND:Percutaneous balloon pulmonary valvuloplasty (PBPV) is the procedure of choice for uncomplicated severe or symptomatic pulmonary stenosis. Echocardiography (echo)-guided PBPV can completely avoid the use of radiation and contrast agents compared to fluoroscopy-guided PBPV. Although we have confirmed that echo-guided PBPV is feasible in humans, the poor visibility of the traditional catheter under echo greatly limits the promotion of this new technology.METHODS:We produced a novel double-balloon catheter to make the catheter easy to be detected by echo through adding a guiding balloon at the distal end of the catheter. Echo-guided PBPV was performed on thirty healthy swine using either a novel catheter or a traditional catheter to evaluate the feasibility and safety of the novel double-balloon catheter. The feasibility was evaluated by the success rate of balloon inflation at the pulmonary valve annulus and the operating time. The safety was evaluated by the frequency of balloon slippage and the incidence of complications.RESULTS:There were no significant between-group differences in terms of weight and the ratio of balloon diameter to pulmonary annulus diameter. The success rate was 93.3% and 60% in the novel and traditional groups, respectively. The novel group had significantly (p<0.05) lower mean procedure time (6.33±6.86min vs 24.8±9.79min) and lower frequency of balloon slippage (0.07±0.26 vs 0.53±0.52), arrhythmia (0.07±0.26 vs 0.47±0.52), and tricuspid regurgitation (6.7% vs 40%) than the traditional group. No myocardial hematoma or pericardial tamponade occurred in the novel catheter group.CONCLUSION:Although further studies and improvements are required, the study results indicate that the novel double-balloon catheter for echo-guided PBPV is feasible and safe.
Journal of cardiology 2020
JACC. Cardiovascular interventions 2020
BACKGROUND:Percutaneous balloon aortic valvuloplasty (PBAV) is an alternative to surgical valvulotomy for the treatment of congenital aortic stenosis (AS). This article aims to summarize our preliminary experience on feasibility and safety of PBAV under only echocardiographic guidance in patients with congenital AS.METHODS:Clinical data from 20 consecutive patients with aortic valve stenosis who underwent PBAV under only echocardiographic guidance at Fuwai Hospital from January 2016 to January 2019 were analyzed retrospectively. Median age of patients was 18.38±15.88 years and 65% of the patients were male. Aortic annulus diameter was 18.40±3.25 mm and balloon diameter was 17.38±3.89 mm, with B/A ratio of 0.93±0.06.RESULTS:All the patients successfully underwent PBAV. The peak transaortic gradient (TG) significantly decreased from 81.59±24.91 (range, 58-112) mmHg preoperatively to 36.32±12.83 (range, 16-51) mmHg (P=0.000) immediately post operation, without significant difference in aortic regurgitation (AR). At mean 24.31±17.35 months follow-up, peak TG was 37.06±13.52 (range, 21-58) mmHg which was not significantly different from the immediate postoperative value (P=0.65).CONCLUSIONS:In this retrospective, single center study, systematic use of Doppler echocardiography as only guidance modality for PBAV was feasible and associated with a high success rate and a very low complication rate.
Journal of thoracic disease 2020
Objective:To assess the effectiveness of a novel ultrasound wire for echo-guiding percutaneous atrial septal defect (ASD) closure in a sheep model.Methods:After right lateral thoracotomy, ASDs were created in 20 sheep by transseptal needle puncture followed by balloon dilatation. Animals were evenly randomized into 2 groups to undergo ASD closure using echography as the only imaging tool with either COOK wire (control group) or new ultrasound wire (study group). The total procedural time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into the right atrium, frequency of arrhythmias, and 1-week rate of complications were compared between the two groups.Results:All animals survived defect creation procedures uneventfully. ASD devices were successfully implanted in all sheep. Compared with the control group, the study group had significantly (P < 0.05) lower mean procedure time (15.36 ± 4.86 versus 25.82 ± 7.85 min), lower mean passing time (2.69 ± 0.82 versus 5.58 ± 3.34 min), lower frequency of the guide wire dropping into the right atrium (0% versus 40%), and lower frequency of atrial (4.41 ± 2.61 versus 9.60 ± 3.68) or ventricular premature contractions (0.75 ± 0.36 versus 1.34 ± 0.68), respectively, without serious complications up to one week.Conclusion:The novel ultrasound specialized guide wire was effective in echo-guiding percutaneous ASD closure.
Journal of healthcare engineering 2018