The intraventricular blood flow changed by blood pump flow dynamics may correlate with thrombosis and ventricular suction. The flow velocity, distribution of streamlines, vorticity, and standard deviation of velocity inside a left ventricle failing to different extents throughout the cardiac cycle when supported by an axial blood pump were measured by particle image velocimetry (PIV) in this study. The results show slower and static flow velocities existed in the central region of the left ventricle near the mitral valve and aortic valve and that were not sensitive to left ventricular (LV) failure degree or LV pressure. Strong vorticity located near the inner LV wall around the LV apex and the blood pump inlet was not sensitive to LV failure degree or LV pressure. Higher standard deviation of the blood velocity at the blood pump inlet decreased with increasing LV failure degree, whereas the standard deviation of the velocity near the atrium increased with increasing intraventricular pressure. The experimental results demonstrated that the risk of thrombosis inside the failing left ventricle is not related to heart failure degree. The "washout" performance of the strong vorticity near the inner LV wall could reduce the thrombotic potential inside the left ventricle and was not related to heart failure degree. The vorticity near the aortic valve was sensitive to LV failure degree but not to LV pressure. We concluded that the risk of blood damage caused by adverse flow inside the left ventricle decreased with increasing LV pressure.
The International journal of artificial organs 2021
Blood flow inside the left ventricle (LV) is a concern for blood pump use and contributes to ventricle suction and thromboembolic events. However, few studies have examined blood flow inside the LV after a blood pump was implanted. In this study, in vitro experiments were conducted to emulate the intraventricular blood flow, such as blood flow velocity, the distribution of streamlines, vorticity and the standard deviation of velocity inside the LV during axial blood pump support. A silicone LV reconstructed from computerized tomography (CT) data of a heart failure patient was incorporated into a mock circulatory loop (MCL) to simulate human systemic circulation. Then, the blood flow inside the ventricle was examined by particle image velocimetry (PIV) equipment. The results showed that the operating conditions of the axial blood pump influenced flow patterns within the LV and areas of potential blood stasis, and the intraventricular swirling flow was altered with blood pump support. The presence of vorticity in the LV from the thoracic aorta to the heart apex can provide thorough washing of the LV cavity. The gradually extending stasis region in the central LV with increasing blood pump support is necessary to reduce the thrombosis potential in the LV.
The International journal of artificial organs 2021