王春元

中国医学科学院阜外医院

Red blood cell membrane-functionalized Nanofibrous tubes for small-diameter vascular grafts.

The off-the-shelf small-diameter vascular grafts (SDVGs) have inferior clinical efficacy. Red blood cell membrane (Rm) has easy availability and multiple bioactive components (such as phospholipids, proteins, and glycoproteins), which can improve the clinic's availability and patency of SDVGs. Here we developed a facile approach to preparing an Rm-functionalized poly-ε-caprolactone/poly-d-lysine (Rm@PCL/PDL) tube by co-incubation and single-step rolling. The integrity, stability, and bioactivity of Rm on Rm@PCL/PDL were evaluated. The revascularization of Rm@PCL/PDL tubes was studied by implantation in the carotid artery of rabbits. Rm@PCL/PDL can be quickly prepared and showed excellent bioactivity with good hemocompatibility and great anti-inflammatory. Rm@PCL/PDL tubes as the substitute for the carotid artery of rabbits had good patency and quick remodeling within 21 days. Rm, as a "self" biomaterial with high biosafety, provides a new and facile approach to developing personalized or universal SDVGs for the clinic, which is of great significance in cardiovascular regenerative medicine and organ chip.

14.0
1区

Biomaterials 2023

Impact of Preoperative Quantitative Flow Ratio of the Left Anterior Descending Artery on Internal Mammary Artery Graft Patency and Midterm Patient Outcomes After Coronary Artery Bypass Grafting.

Background In coronary artery bypass grafting, grafting a target vessel with nonsignificant stenosis increases the risk of graft failure. The present study aims to investigate the impact of preoperative quantitative flow ratio (QFR), a novel functional assessment of the coronary artery, on internal mammary artery graft failure rate and midterm patient outcomes. Methods and Results Between January 2016 and January 2020, we retrospectively included 419 patients who underwent coronary artery bypass grafting who had received preoperative angiography and postoperative coronary computed tomographic angiography in our center. QFR of the left anterior descending (LAD) artery was computed based on preoperative angiograms. The primary end point was the failure of the graft on the LAD artery assessed by coronary computed tomographic angiography at 1 year, and the secondary end point was major adverse cardiac and cerebrovascular events including death from any cause, myocardial infarction, stroke, or repeat revascularization. Grafts on functionally nonsignificant LAD arteries (QFR >0.80) had a significantly higher failure rate than those on functionally significant LAD arteries (31.4% versus 7.2%, P<0.001). QFR outperforms degree of stenosis in discriminating graft failure (C statistic, 0.76 versus 0.58). Clinical follow-up (3.6 years, interquartile range [3.3-4.1]) was accomplished in 405 patients, and the rate of major adverse cardiac and cerebrovascular events was significantly higher among patients with functionally nonsignificant LAD arteries (10.1% versus 4.2%; adjusted hazard ratio, 3.08 [95% CI, 1.18-8.06]; P=0.022). Conclusions In patients receiving internal mammary artery to LAD artery coronary artery bypass grafting, preoperative QFR of the LAD artery of >0.80 was associated with a higher graft failure rate at 1 year and worse patient outcomes at the 3.6-year follow-up.

5.4
1区
第一作者

Journal of the American Heart Association 2023

Potential of Quantitative Flow Ratio for Selecting Target Vessels for Radial Artery Grafting: A Retrospective Observational Study.

37.8
1区

Circulation 2023