朱浩杰

中国医学科学院阜外医院 心律失常中心

New-onset atrial fibrillation following left bundle branch area pacing vs. right ventricular pacing: a two-centre prospective cohort study.

AIMS:To investigate whether left bundle branch area pacing (LBBAP) can reduce the risk of new-onset atrial fibrillation (AF) compared with right ventricular pacing (RVP).METHODS AND RESULTS:Patients with indications for dual-chamber pacemaker implant and no history of AF were prospectively enrolled if they underwent successful LBBAP or RVP. The primary endpoint was time to the first occurrence of AF detected by pacemaker programming or surface electrocardiogram. Follow-up at clinic visit was performed and multivariate Cox regression models were applied to evaluate the effect of LBBAP on new-onset AF. The final analysis included 527 patients (mean age 65.3 ± 12.6, male 47.3%), with 257 in the LBBAP and 270 in the RVP groups. During a mean follow-up of 11.1 months, LBBAP resulted in significantly lower incidence of new-onset AF (7.4 vs. 17.0%, P < 0.001) and AF burden (3.7 ± 1.9 vs. 9.3 ± 2.2%, P < 0.001) than RVP. After adjusting for confounding factors, LBBAP demonstrated a lower hazard ratio for new-onset AF compared with RVP {hazard ratio (HR) [95% confidence interval (CI)]: 0.278 (0.156, 0.496), P < 0.001}. A significant interaction existed between pacing modalities and the percentage of ventricular pacing (VP%) (P for interaction = 0.020). In patients with VP ≥ 20%, LBBAP was associated with decreased risk of new-onset AF compared with RVP [HR (95% CI): 0.199 (0.105, 0.378), P < 0.001]. The effect of pacing modalities was not pronounced in patients with VP < 20% [HR (95% CI): 0.751 (0.309, 1.823), P = 0.316].CONCLUSION:Left bundle branch area pacing demonstrated a reduced risk of new-onset AF compared with RVP. Patients with a high ventricular pacing burden might benefit from LBBAP.

6.1
1区
第一作者

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2023

Tricuspid regurgitation following pacemaker implantation for bradycardia: a two-year study comparing different pacing strategies.

6.1
3区

Chinese medical journal 2023

Early left bundle branch pacing in heart failure with mildly reduced ejection fraction and left bundle branch block.

BACKGROUND:Left bundle branch pacing (LBBP) achieves resynchrony and improves cardiac function in heart failure (HF) patients with reduced ejection fraction (EF) by correcting left bundle branch block (LBBB). Few data on the efficacy of early LBBP in HF with mildly reduced EF (HFmrEF) and LBBB have been reported.OBJECTIVE:The purpose of this study was to explore the efficacy of early LBBP in patients with HFmrEF and LBBB.METHODS:Consecutive patients with HFmrEF (left ventricular EF [LVEF] 35%-50%) and LBBB were prospectively enrolled to receive LBBP (Early-LBBP group) plus guideline-directed medical therapy (GDMT) or GDMT alone (GDMT group). Study outcomes included changes in LVEF, LV end-diastolic diameter (LVEDD), New York Heart Association (NYHA) functional classification, and N-terminal pro-brain natriuretic peptide (NT-proBNP), and clinical events (HF rehospitalization or syncope). Subgroup analysis compared efficacy of LBBP between patients with LBBB only without comorbidities or late gadolinium enhancement (LGE) (LBBB-Only group) and patients with either comorbidities or LGE (LBBB-Combined group).RESULTS:Fifty-four patients were enrolled and analyzed (37 Early-LBBP group; 15 GDMT group). LBBP achieved greater improvement in LVEF (+14.75% ± 7.37% vs -2.42% ± 2.84%; P <.001), reduction of LVEDD (-7.51 ± 5.40 mm vs -0.87 ± 4.36 mm; P <.001) and NYHA classification (-0.84 ± 0.76 vs -0.13 ± 0.74; P = .004), and similar reduction of NT-proBNP (-408.83 ± 920.29 pg/mL vs -229.05 ± 1579.17 pg/mL; P = .610) at 6 months. Early LBBP showed significantly reduced clinical events (0.0% vs 40.0%; P <.001) after 20.68 ± 13.55 months of follow-up. Subgroup analysis showed patients in the LBBB-Only group benefited more from LBBP with regard to LVEF improvement and LVEDD reduction than the LBBB-Combined group.CONCLUSION:Early LBBP with GDMT demonstrated greater improvement of cardiac function and reduced clinical events than GDMT alone in patients with HFmrEF and LBBB.

5.5
2区

Heart rhythm 2023

The initial experience of left bundle branch area pacing in patients with hypertrophic cardiomyopathy.

PURPOSE:Whether left bundle branch area pacing (LBBAP) could be achieved in patients with hypertrophic cardiomyopathy (HCM) requiring ventricular pacing remains unknown. The present study aimed to investigate the feasibility and effect of LBBAP in HCM.METHODS:Patients with HCM who underwent LBBAP were recruited from November 2018 to September 2021. Clinical characteristics, echocardiographic, and pacing parameters were prospectively collected at baseline and during follow-up.RESULTS:Eleven consecutive HCM patients who attempted LBBAP were included (mean age 64.0 ± 8.7 years, female 45.5%, mean interventricular septum 16.7 mm). The success rate of LBBAP was 36.4% (4/11) and the reason for failed LBBAP in other seven HCM patients was the inability to screw the lead into the deep septum or capture the left bundle branch. Patients with successful LBBAP had significantly narrower QRS duration than those with failed cases (118.0 ± 3.7 ms vs. 140.9 ± 9.4 ms, p = .01) while the capture thresholds, sensing amplitudes, and pacing impedances were similar. Successful cases presented with less positive late gadolinium enhancement (25.0% vs. 71.4%, p = .02) and thinner interventricular septum thickness (14.5 ± 1.0 mm vs. 18.0 ± 2.5 mm, p = .02) compared with failed cases. Pacing parameters remained stable and no procedure-related complications occurred during a mean follow-up of 8.9 ± 7.3 months.CONCLUSION:LBBAP may be successfully achieved in less than half of HCM patients due to thick interventricular septum and heavy burden of myocardial fibrosis. Pacing strategies should be cautiously considered in patients with HCM.

1.8
4区
第一作者

Pacing and clinical electrophysiology : PACE 2022

Tricuspid regurgitation outcomes in left bundle branch area pacing and comparison with right ventricular septal pacing.

5.5
2区

Heart rhythm 2022

Randomized Trial of Left Bundle Branch vs Biventricular Pacing for Cardiac Resynchronization Therapy.

BACKGROUND:Left bundle branch pacing (LBBP) is the most rapidly growing conduction system pacing technique that is capable of correcting intrinsic left bundle branch block (LBBB). As such, it is potentially an optimal alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BiVP).OBJECTIVES:The authors sought to compare the efficacy of LBBP-CRT with BiVP-CRT in patients with heart failure and reduced left ventricular ejection fraction (LVEF).METHODS:This is a prospective, randomized trial of patients with nonischemic cardiomyopathy and LBBB with 6-month preplanned follow-up. Crossovers were allowed if LBBP or BiVP were unsuccessful. The primary endpoint was the difference in LVEF improvement between 2 groups. The secondary endpoints included changes in echocardiographic measurements, N-terminal pro-B-type natriuretic peptide (NT-proBNP), New York Heart Association functional class, 6-minute walk distance, QRS duration, and CRT response.RESULTS:The study included 40 consecutive patients (20 males, mean age 63.7 years, LVEF 29.7% ± 5.6%). Crossovers occurred in 10% of LBBP-CRT and 20% of BiVP-CRT. All patients completed follow-up. Intention-to-treat analysis showed significantly higher LVEF improvement at 6 months after LBBP-CRT than BiVP-CRT (mean difference: 5.6%; 95% CI: 0.3-10.9; P = 0.039). LBBP-CRT also appeared to have greater reductions in left ventricular end-systolic volume (-24.97 mL; 95% CI: -49.58 to -0.36 mL) and NT-proBNP (-1,071.80 pg/mL; 95% CI: -2,099.40 to -44.20 pg/mL), and comparable changes in New York Heart Association functional class, 6-minute walk distance, QRS duration, and rates of CRT response compared with BiVP-CRT.CONCLUSIONS:LBBP-CRT demonstrated greater LVEF improvement than BiVP-CRT in heart failure patients with nonischemic cardiomyopathy and LBBB. (Left Bundle Branch Pacing Versus Biventricular Pacing for Cardiac Resynchronization Therapy [LBBP-RESYNC]; NCT04110431).

24.0
1区

Journal of the American College of Cardiology 2022

Left bundle branch area pacing versus right ventricular pacing in patients with persistent atrial fibrillation requiring ventricular pacing.

PURPOSE:This study aims to assess whether left bundle branch area pacing (LBBAP) can result in favorable clinical and echocardiographic outcomes among patients with persistent atrial fibrillation (PeAF).METHODS:We prospectively enrolled consecutive patients with PeAF if they required ventricular pacing and had left ventricular ejection fraction (LVEF) > 35%. During the same period, two experienced operators performed LBBAP and right ventricular pacing (RVP). All-cause death and heart failure hospitalization (HFH) were routinely followed after procedure. The primary outcome was the composite endpoints of all-cause death or HFH.RESULTS:LBBAP was successful in 49 of 52 patients (94.2%), whereas 44 patients received RVP. During a mean follow-up of 13.9 ± 7.0 months, LBBAP group presented with higher ventricular pacing percentage (80% vs. 50.9%, p = .04) and narrower paced QRS duration (117.2 ± 18.8 ms vs. 151.8 ± 13.7 ms, p < .001) than RVP group. The primary endpoint was slightly reduced in LBBAP group than RVP without reaching statistical significance (7.7% vs. 11.4%, p = .48). Compared with baseline, we observed significant changes in LVEF (+0.7% vs. -2.2%, p = .007) and left atrial diameter (-1.63 mm vs. +1.23 mm, p = .011) between LBBAP and RVP.CONCLUSION:Our results indicate possible effect of LBBAP on reverse remodeling of left atrium and a trend towards favorable clinical outcomes in patients with PeAF requiring high burden of ventricular pacing when compared with RVP.

1.8
4区

Pacing and clinical electrophysiology : PACE 2021

Medium- and Long-Term Lead Stability and Echocardiographic Outcomes of Left Bundle Branch Area Pacing Compared to Right Ventricular Pacing.

The long-term lead stability and echocardiographic outcomes of left bundle branch area pacing (LBBAP) are not fully understood. This study aimed to observe the mid-long-term clinical impact of LBBAP compared to right ventricular pacing (RVP). Consecutive bradycardia patients undergoing LBBAP or RVP were enrolled. Pacing and electrophysiological characteristics, echocardiographic measurements, and procedural complications were prospectively recorded at baseline and follow-up. LBBAP was successful in 376 of 406 patients (92.6%), while 313 patients received RVP. During a mean follow-up of 13.6 ± 7.8 months, LBBAP presented with similar pacing parameters and complications to RVP, except a significantly narrower paced QRS duration (115.7 ± 12.3 ms vs. 148.0 ± 18.0 ms, p < 0.001). In 228 patients with ventricular pacing burden >40%, LBBAP at last follow-up resulted in decreased left atrial diameter (LAD) (40.1 ± 8.5 mm vs. 38.5 ± 8.0 mm, p < 0.001) while RVP produced decreased left ventricular ejection fraction (62.7 ± 4.8% vs. 60.5 ± 6.9%, p < 0.001) when compared to baseline. After adjusting for age, the presence of atrial fibrillation, and other clinical factors, LBBAP was still associated with a decrease in LAD (-1.601, 95% CI -3.094--0.109, p = 0.036). We conclude that LBBAP might result in more preserved echocardiographic outcomes than RVP.

2.4
4区
第一作者

Journal of cardiovascular development and disease 2021

Comparison of Procedure and Fluoroscopy Time Between Left Bundle Branch Area Pacing and Right Ventricular Pacing for Bradycardia: The Learning Curve for the Novel Pacing Strategy.

Background: Left bundle branch area pacing (LBBAP) is a novel physiological pacing approach. Objective: To assess learning curve for LBBAP and compare the procedure and fluoroscopy time between LBBAP and right ventricular pacing (RVP). Methods: Consecutive bradycardia patients who underwent LBBAP or RVP were prospectively recruited from June 2018 to June 2020. The procedure and fluoroscopy time for ventricular lead placement, pacing parameters, and periprocedural complications were recorded. Restricted cubic splines were used to fit learning curves for LBBAP. Results: Left bundle branch area pacing was successful in 376 of 406 (92.6%) patients while 313 patients received RVP. Learning curve for LBBAP illustrated initial (1-50 cases), improved (51-150 cases), and stable stages (151-406 cases) with gradually increased success rates (88.0 vs. 90.0 vs. 94.5%, P = 0.106), steeply decreased median procedure (26.5 vs. 14.0 vs. 9.0min, P < 0.001) and fluoroscopy time (16.0 vs. 6.0 vs. 4.0min, P < 0.001), and shortened stimulus to left ventricular activation time (Sti-LVAT; 78.7 vs. 78.1 vs. 71.2 ms, P < 0.001). LBBAP at the stable stage showed longer but close median procedure (9.0 vs. 6.9min, P < 0.001) and fluoroscopy time (4.0 vs. 2.8min, P < 0.001) compared with RVP. Conclusion: The procedure and fluoroscopy time of LBBAP could be reduced significantly with increasing procedure volume and close to that of RVP for an experienced operator.

3.6
3区

Frontiers in cardiovascular medicine 2021