OBJECTIVE:To study the prevalence of atrial fibrillation (AF) and the relation with its risk factors in China.METHODS:A total of 19 363 participants (8635 males and 10 728 females) aged ⋝35 years in geographically dispersed urban and rural regions of China were included in this cross-sectional survey. All participants received questionnaire, physical and blood examination. Echocardiography were performed for AF patients found in the survey.RESULTS:Of the 19 363 participants, 199 were diagnosed with AF. The estimated age-standardized prevalence of AF was 0.78% in men and 0.76% in women. The prevalence of AF in participants aged <60 years was 0.41% in men and 0.43% in women, and was 1.83% in both men and women aged ⋝60 years. About 19.0% of males and 30.9% of females with AF were diagnosed with valve disease. Age- and sex-adjusted multivariable logistic regression analysis revealed that myocardial infarction, left ventricular hypertrophy (LVH), obesity, and alcohol consumption were associated with a increased risk of AF(P<0.05).CONCLUSION:The age standardized prevalence of AF is 0.77% in the participants enrolled in the present study. The number of AF cases aged ⋝35 years is 5.26 million according to 2010 Chinese Census. Most risk factors for AF, identified mainly in Western countries, are also detected in China.
Biomedical and environmental sciences : BES 2013
BACKGROUND:P-wave dispersion (PWD) is a useful predictor of paroxysmal atrial fibrillation (AF). The effect of cardiac resynchronization therapy (CRT) on PWD and the prognostic implications of the improvement in PWD remain undefined. The aim of the study was to explore the clinical significance of the improvement of PWD after CRT.METHODS:Electrocardiographic studies were performed before and three months after CRT in 81 patients (57 men and 24 women; age (60.5 ± 11.2) years) with standard CRT indication but no history of AF. A significant improvement of PWD (PWD responder) was defined as a relative decrease ≥ 20% from baseline PWD. The primary endpoints were new-onset AF detected by electrocardiogram (ECG) or CRT.RESULTS:After (30.6 ± 7.5) months of follow-up, PWD responders (n = 43) had a significantly lower incidence of AF than did PWD nonresponders, 12% vs. 29% (P < 0.001). In Cox proportional hazard analysis, PWD responders was the only predictor of lower risk of new-onset AF (HR 0.33, 95% confidence interval 0.12 - 0.96, P = 0.033).CONCLUSION:Improvement of P-wave dispersion after CRT was associated with a lower incidence of AF, which may be related to the significant improvement in left ventricular systolic function and the reverse modeling of the left atrium.
Chinese medical journal 2012
UNLABELLED:Preventive Effectiveness of Implantable Cardioverter.INTRODUCTION:This prospective and multicenter trial of the implantable cardioverter-defibrillator (ICD) aimed to evaluate the mortality rate (including sudden cardiac death [SCD]) and the efficacy of ICD in Chinese patients with high risk of sudden death.METHODS AND RESULTS:This trial was conducted in 31 centers in China. We enrolled 497 patients who fulfilled Class I indication for ICD (2002 ACC/AHA/NASPE guideline). All patients were followed-up at 3, 6, and 12 months. Clinical characteristics and echocardiographic parameters were collected at baseline and follow-up; Kaplan-Meier survival analysis was performed. Among 497 enrolled patients with Class I indication of ICD therapy, 112 (22.5%) agreed to and received ICD implantation (ICD group). The remaining 385 patients who were not available for ICD therapy were designated as the non-ICD group. During a mean follow-up of 11 ± 3 months, there were a total of 38 deaths, 2 in the ICD group with a mortality of 1.8% and 36 in the non-ICD group, with a mortality of 9.4% and 26 due to SCD. The overall survival rate was 93% at 3 months of follow-up, 91% at 6 months, and 89% at 12 months, with an incidence of SCD of 5%, 7%, and 8% at 3, 6, and 12 months, respectively.CONCLUSIONS:In patients with Class I indication of ICD implantation, the total mortality and incidence of SCD were high. ICD therapy can effectively reduce the mortality in such patients.
Journal of cardiovascular electrophysiology 2012
BACKGROUND:Although cardiac resynchronization therapy (CRT) is already an established treatment, the characteristics of patients who have an excellent response to CRT and those who get no benefit remain to be determined. The purpose of this study was to search for potential predictors of both non-response and super-response to CRT.METHODS:Seventy-six consecutive patients who received CRT treatment were divided into group A (non-responders), group C (super-responders) and group B (responders exclusive of super-responders). Student's t test, Mann-Whitney test, Logistic regression and receiver operating characteristic curve were employed to identify potential predictors among the patients' demographic characteristics, clinical features, several electrocardiographic parameters before and after CRT implantation, and their pre-implant echocardiographic parameters.RESULTS:Group A had the lowest 3-month left ventricular ejection fraction (LVEF). Group C had the smallest pre-implant left ventricular end-diastolic dimension (LVEDD), the shortest post-implant QRS duration, the smallest 3-month LVEDD and the highest 3-month LVEF. In addition, there was a trend of gradual change in percent of left bundle branch block, severity of pre-implant mitral regurgitation, pre-implant QRS dispersion, post-implant QRS duration as well as post-implant QRS dispersion from group A to group B and from group B to group C. Multivariable Logistic analysis revealed that only pre-implant LVEDD could predict CRT super-response. A pre-implant LVEDD of 68.5 mm was the cut-off value that identified super-responders with 87.5% sensitivity and 79.7% specificity. A pre-implant LVEDD of 62.5 mm identified super-responders with 50.0% sensitivity and 89.8% specificity.CONCLUSIONS:Predictors of a CRT non-response remain unclear at present. But it is credible that patients with a smaller left ventricle would have a better chance to become super-responders to CRT.
Chinese medical journal 2011
BACKGROUND:The Medtronic InSync Sentry is the first available cardiac resynchronization therapy defibrillator (CRT-D) which can monitor fluid status by measuring intrathoracic impedance. This study was designed to observe the effectiveness of intrathoracic impedance monitoring on detecting aggravation of heart failure.METHODS:We retrospectively analyzed the clinical data of 14 consecutive patients. Patients were regularly followed up every 3 - 6 months after the implantation. At each visit, interrogation of the device was done. Patients were instructed to inform the researcher on hearing the device alert, and to take extra 40 milligrams of furosemidum if they had aggravated symptoms later. If the symptoms could not be relieved, they were asked to see a doctor. Data about heart failure hospitalization were collected from the medical record.RESULTS:During 18 - 48 months follow-up, a total of 7 patients encountered 28 alert events. On one hand, alert events appeared before all deteriorated symptoms and heart failure hospitalizations. On the other hand, there were 23 alerts followed by deterioration of heart failure symptoms, and 2 alerts related to 2 hospitalizations caused by pulmonary infection in one patient. Only 5 patients were hospitalized 10 times for deterioration of cardiac function.CONCLUSION:The function of intrathoracic impedance monitoring is reliable in predicting deterioration of heart failure.
Chinese medical journal 2011
A 62-year-old woman with frequent occurrence of symptomatic atrial tachycardia with a foci located at the root of the upper crista terminalis was found to have right diaphragm paresis after receiving a total of 8 radiofrequency energy deliveries (40-60 W, 50-60ºC) and a total duration of 540 seconds of ablation therapy (7Fr 8 mm deflectable ablation catheter). The right diaphragm paresis remained resolved up to 14 months after the procedure as confirmed by repeated chest X-rays.
Chinese medical journal 2011
BACKGROUND:Ventricular tachycardia (VT) and ventricular fibrillation are the main reasons causing sudden cardiac death. This study aimed to investigate the effects of nifekalant hydrochloride (NIF) on QT dispersion (QTd) in treating VT.METHODS:A total of 16 consecutive patients suffered sustained VT was included and then randomly divided into two groups according to the administration duration of NIF. In long-time group (group L), patients were injected with NIF continuously for at least 12 hours after a bolus dose. The patients in short-time group (group S) were injected with NIF just for 1 hour.RESULTS:There were 7 of all 10 episodes of VT which were terminated by NIF, including 4 episodes in group L were stopped over 1 hour after continuous infusion of NIF. One patient suffered from torsade de pointes. Electrocardiography analysis indicated that QTd was significantly decreased 12 hours after stopping of infusing NIF compared with that when VT stopped ((45.4 +/- 22.1) ms vs. (73.4 +/- 33.2) ms, P < 0.01), and the corrected QTd (QTcd) decreased too ((47.8 +/- 22.9) ms vs. (78.3 +/- 36.5) ms, P < 0.01). There was a positive correlation between the increase in QTd and dose of administrating NIF (P < 0.01), so was QTcd (P < 0.01).CONCLUSIONS:More administration of NIF indicates higher terminating rate of VT and more QTd prolongation. However, the safety is acceptable if several important issues were noticed in using NIF, such as serum potassium concentration, stopping side-effect related agents, and carefully observing clinical responses.
Chinese medical journal 2010
OBJECTIVE:To evaluate the value of 64-slice computed tomography (MDCT) in previsualization the cardiac veins anatomy before the implantation of cardiac resynchronization therapy (CRT).METHODS:The 64-slice CT scans of 21 patients [10 men, age (61.6 ± 9.7) years] were obtained and analyzed before the implantation of CRT. Retrograde coronary venography was performed during intraoperational fluoroscopy. The coronary sinus (CS) and the main tributaries were measured.RESULTS:Similar images to those obtained during the CRT implantation procedure were obtained by MDCT in 71% of the patients. The coronary sinus was clearly visible in all cases, the measured ostium was (12.1 ± 4.2) mm, and the angle between the CS and the vertical plane was (99 ± 12) degrees. In 90% of patients, at least one vein was clearly visible in the target area. Among the target veins, the posterolateral vein was visible in most cases (86%) and the lateral vein was visible in 48% of the patients.CONCLUSION:MDCT is an effective and noninvasive method for previsualization of the cardiac venous system, which may facilitate optimal left ventricular lead positioning for CRT implantation.
Zhonghua xin xue guan bing za zhi 2010
OBJECTIVE:To analyse the reasons for pacing lead abandonment during pacemaker replacement.METHOD:Clinical data of patients underwent permanent pacemaker replacement between Jan 1st, 1976 to Dec 31st 2006 in Fuwai Hospital were obtained and the reasons for pacing leads abandonment were analyzed.RESULTS:Pacemaker was replaced in 1023 patients during this period and 235 pacing leads were abandoned, 131 leads (55.7%) were abandoned for leads malfunction, including leads body fracture (35, 14.9%), isolation defects (10, 4.3%), dislocations (10, 4.3%) and excessively high threshold values (76, 32.3%). Other reasons for leads abandonment were infection (50, 21.3%), incompatibility between the leads and new generator (30, 12.8%), need to degrade the pacing system (13, 5.5%) and other rare reasons (11, 4.7%).CONCLUSION:The most often reason for leads abandonment during pacemaker replacement is lead malfunction, including lead body fracture, isolation defect, dislocation and excessively high threshold value of the leads.
Zhonghua xin xue guan bing za zhi 2009
OBJECTIVE:To study the factors influencing the outcome of patients suffering from in-hospital ventricular fibrillation (IHVF), as there have been few studies focusing on this topic.METHODS:Patients with IHVF collected in a single cardiac center were classified into a successful group and a failure group. Data relevant to the predicting factors of the two groups were compared.RESULTS:There were 206 events in the analysis. The most common underlining disease was coronary artery disease (CAD), especially acute myocardial infarction (AMI). On multiple logistic regression analysis, it was shown that the independent predictors for failure of defibrillation were higher NYHA class (OR 1.7, 95% CI 1.3 - 2.2, P < 0.001), higher blood potassium level (OR 2.9, 95% CI 1.9 - 4.3, P = 0.007) and adrenaline usage (OR 25.0, 95% CI 11.5 - 55.1, P < 0.001). In a AMI sub-group, 56.9% of the IHVF events occurred within the first day of AMI, and the occurrence descended with time going on within 2 weeks. Before the occurrence of IHVF, the patients with right coronary artery as the infarction related artery (IRA) often suffered from (8/9, 88.9%) bradycardia (R-R interval > 1 s), but those with left anterior descending artery as IRA often showed (8/12, 66.7%) tachycardia (RR interval < 0.6 s).CONCLUSIONS:The common disease causing IHVF is CAD. The worse the heart function, the higher the rate of IHVF and the worse the prognosis. It IHVF not induced by hypokalemia and use of adrenaline in resuscitation predict lower successful defibrillation rate.
Zhonghua nei ke za zhi 2009