李世国

中国医学科学院阜外医院 放射科

Mechanism of METTL3-Mediated m6A Modification in Cardiomyocyte Pyroptosis and Myocardial Ischemia-Reperfusion Injury.

OBJECTIVE:Myocardial ischemia/reperfusion (MI/R) injury is a complicated pathophysiological process associated with cardiomyocyte pyroptosis. Methyltransferase-like protein 3 (METTL3) catalyzes the formation of N6-methyl-adenosine (m6A) and participates in various biological processes. This study probed into the mechanism of METTL3 in cardiomyocyte pyroptosis in MI/R injury.METHODS:A rat model of MI/R was established. Rat cardiomyocytes were subjected to oxygen-glucose deprivation/reoxygenation (OGD/R) treatment for the establishment of a cell model in vitro. METTL3 expression in myocardial tissues of MI/R rats and OGD/R-treated cardiomyocytes was determined using RT-qPCR and Western blot. The pathological changes of rat myocardial tissues were observed using hematoxylin and eosin staining. The positive expression of NLRP3 in myocardial tissues or cardiomyocytes was observed through immunohistochemistry or immunofluorescence. The activity of caspase-1 was measured using the colorimetric method. The expressions of GSDMD and cleaved caspase-1, as well as the levels of IL-1β and IL-18 in rat myocardial tissues or cardiomyocytes were determined. m6A modification level was quantified. The binding relationship between pri-miR-143-3p and DGCR8 and the enrichment of m6A on pri-miR-143-3p were detected. The binding relationship between miR-143-3p and protein kinase C epsilon (PRKCE) was verified.RESULTS:METTL3 expression was elevated in MI/R rats and OGD/R cardiomyocytes. METTL3 silencing alleviated myocardial injury, reduced the number of NLRP3-positive cardiomyocytes, suppressed caspase-1 activity, decreased the protein levels of GSDMD-N and cleaved caspase-1, and decreased IL-1β and IL-18 levels. METTL3 increased the total m6A level in MI/R rats and injured cardiomyocytes, promoted DGCR8 binding to pri-miR-143-3p, and enhanced miR-143-3p expression. miR-143-3p suppressed PRKCE transcription, and miR-143-3p overexpression reversed the inhibitory effect of METTL3 silencing on cardiomyocyte pyroptosis.CONCLUSION:METTL3 promoted DGCR8 binding to pri-miR-143-3p through m6A modification, thus enhancing miR-143-3p expression to inhibit PRKCE transcription and further aggravating cardiomyocyte pyroptosis and MI/R injury.

3.4
3区

Cardiovascular drugs and therapy 2023

Interventional Occlusion of Large Patent Ductus Arteriosus in Adults with Severe Pulmonary Hypertension.

(1) Background: the indications for transcatheter closure of large patent ductus arteriosus (PDA) with severe pulmonary hypertension (PH) are still unclear, and scholars have not fully elucidated the factors that affect PH prognosis. (2) Methods: we retrospectively enrolled 134 consecutive patients with a PDA diameter ≥10 mm or a ratio of PDA and aortic >0.5. We collected clinical data to explore the factors affecting follow-up PH. (3) Results: 134 patients (mean age 35.04 ± 10.23 years; 98 women) successfully underwent a transcatheter closure, and all patients had a mean pulmonary artery pressure (mPAP) >50 mmHg. Five procedures were deemed to have failed because their mPAP did not decrease, and the patients experienced uncomfortable symptoms after the trial occlusion. The average occluder (pulmonary end) size was almost twice the PDA diameter (22.33 ± 4.81 mm vs. 11.69 ± 2.18 mm). Left ventricular end-diastolic dimension (LVEDD), mPAP, and left ventricular ejection fraction (LVEF) significantly reduced after the occlusion, and LVEF recovered during the follow-up period. In total, 42 of the 78 patients with total pulmonary resistance >4 Wood Units experienced clinical outcomes, and all of them had PH in the follow-up, while 10 of them had heart failure, and 4 were hospitalized again because of PH. The results of a logistic regression analysis revealed that the postoperative mPAP had an independent risk factor (odds ratio = 1.069, 95% confidence interval: 1.003 to 1.140, p = 0.040) with a receiver operating characteristic curve cut-off value of 35.5 mmHg (p < 0.001). (4) Conclusions: performing a transcatheter closure of large patent ductus arteriosus is feasible, and postoperative mPAP was a risk factor that affected the follow-up PH. Patients with a postoperative mPAP >35.5 mmHg should be considered for targeted medical therapy or should undergo right heart catheterization again after the occlusion.

3.9
3区

Journal of clinical medicine 2023

First in-human modified atrial septostomy combining radiofrequency ablation and balloon dilation.

OBJECTIVE:Preclinical research suggests that the combined use of radiofrequency ablation and balloon dilation (CURB) could create stable interatrial communications without device implantation. This study examined the first in-human use of CURB for modified atrial septostomy in patients with severe pulmonary arterial hypertension (PAH).METHODS:Between July 2018 and October 2021, CURB was performed in 19 patients with severe PAH (age: 31.5±9.1 years; mean pulmonary artery pressure: 73 mm Hg (IQR: 66-92); pulmonary vascular resistance: 18.7 Wood units (IQR: 17.8-23.3)). Under guidance of intracardiac echocardiography and three-dimensional location system, (1) fossae ovalis was reconstructed and ablated point-by-point with radiofrequency; (2) then graded balloon dilation was performed after transseptal puncture and the optimal size was determined according to the level of arterial oxygen saturation (SatO2); (3) radiofrequency ablation was repeated around the rims of the created fenestration. The interatrial fenestrations were followed-up serially.RESULTS:After CURB, the immediate fenestration size was 4.4 mm (IQR: 4.1-5.1) with intracardiac echocardiography, systolic aortic pressure increased by 10.2±6.9 mm Hg, cardiac index increased by 0.7±0.3 L/min/m2 and room-air resting SatO2 decreased by 6.2±1.9% (p<0.001). One patient experienced increased pericardiac effusion postoperatively; the others had no complications. On follow-up (median: 15.5 months), all interatrial communications were patent with stable size (intraclass correlation coefficient=0.96, 95%CI:0.89 to 0.99). The WHO functional class increased by 1 (IQR: 1-2) (p<0.001) with improvement of exercise capacity (+159.5 m, P<0.001).CONCLUSION:The interatrial communications created with CURB in patients with severe PAH were stable and the mid-term outcomes were satisfactory.TRIAL REGISTRATION NUMBER:NCT03554330.

5.7
2区

Heart (British Cardiac Society) 2022

Transcatheter closure of inferior sinus venosus defect using a patent ductus arteriosus occluder following simulation with a 3D-printed model.

Background:Transcatheter closure of inferior sinus venosus defect (ISVD) is still contraindication. To explore whether transcatheter closure with patent ductus arteriosus (PDA) occluders is possible for ISVD.Methods:From June 2014 to March 2021, 12 patients were recruited diagnosed as <25 mm ISVD. The three-dimensional printing (3DP) heart model was produced based on multi-slice computed tomography (MSCT) scans. Preoperative closure simulation was planned on the personalized 3D model for each patient. Follow-up including electrocardiography (ECG), transthoracic echocardiography (TTE), and X-ray was traced.Results:3DP models of 12 patients were successfully printed. Twelve patients had been diagnosed with <25 mm ISVD and 4 of them had another secundum atrial septal defect (ASD). All patients were produced interventional therapy successfully. PDA occluder was implanted to closed ISVD, and ASD was closed using ASD occluder simultaneously. The average diameter of ISVD measured by TTE was (12.67±3.80), and the average diameter of sagittal axes and longitudinal axes measured by the 3D-printed model was (17.08±3.20) and (18.42±4.62) mm, respectively. The average size of PDA (diameter of pulmonary artery side) was (28.17±3.35) mm. Compared with the preoperative, the X-ray cardiothoracic ratio (0.51±0.04 vs. 0.47±0.06, P=0.007) and the right ventricle anterior-posterior diameter (31.17±5.65 vs. 24.58±3.75 mm, P<0.001) of postoperative was significantly decreased. During the average (47.75±27.52) months follow-up, it has achieved satisfying results, and there were no severe adverse events such as device transposition, death, and pericardial tamponade occurred.Conclusions:Assisting by 3D heart model, transcatheter closure of ISVD with PDA occluder had an excellent outcome. This method provides a new considerable treatment strategy for ISVD.

2.5
3区

Journal of thoracic disease 2022

Transcatheter closure of coronary artery fistula draining into left ventricle: a long-term study.

5.9
2区

Revista espanola de cardiologia (English ed.) 2021

Balloon pulmonary angioplasty with distal embolic protection device for chronic thromboembolic pulmonary hypertension.

39.3
1区

European heart journal 2021

Transcatheter Closure of Patent Ductus Arteriosus via Different Approaches.

Background: There have been marked advances in devices such as Amplatzer Duct Occluder II (ADO-II) or vascular plug through 5Fr delivery sheath for closure of patent ductus arteriosus (PDA) in the past five decades, making it possible for cardiologists to deliver occluders via different approaches. However, comparisons of these different approaches have not been reported. Therefore, the aim of this study was to summarize and compare the advantages of different approaches for PDA closure, and to guide clinical strategies. Methods: This retrospective study included all patients undergoing transcatheter closure of PDA from 2019 to 2020. Patients were matched by 1:1 propensity score matching (PSM). The retrograde femoral artery approach (FAA) and simple vein approach (SVA) groups were compared with the conventional arteriovenous approach (CAA). Results: The average age of the 476 patients was 21.05 ± 21.15 years. Their average weight was 38.23 ± 24.1 kg and average height was 130.14 ± 34.45 cm. The mean diameter of the PDA was 4.29 ± 2.25 mm. There were 127 men and 349 women, comprising 205 adults and 271 children. Among them, 197 patients underwent CAA, 223 underwent SVA, and 56 underwent retrograde FAA. The diameter in the FAA group was smaller than that in the other two groups, but was similar in adults and children. In the PSM comparison of CAA and SVA, 136 patients with CAA and 136 patients with SVA were recruited. Simple vein approach was associated with markedly reduced length of hospital stay, length of operation, and contrast medium usage as compared with CAA (all P < 0.05). In the PSM comparison of FAA and CAA, 30 patients with CAA and 30 patients with FAA were recruited. The operation duration was longer in the CAA than in the FAA group. There were no significant differences in postoperative complications among groups. Conclusion: Patent ductus arteriosus closure by using the SVA and FAA is safe and effective, and has certain advantages in some respects as compared with CAA.

3.6
3区

Frontiers in cardiovascular medicine 2021

Combination of F-ASO and Targeted Medical Therapy in Patients With Secundum ASD and Severe PAH.

OBJECTIVES:This study was conducted to investigate the combined use of fenestrated atrial septal occluder (F-ASO) and targeted medical therapy (TMT) in patients with secundum atrial septal defect (ASD) and severe pulmonary arterial hypertension (PAH).BACKGROUND:Treatment of patients with ASD and severe PAH is still challenging.METHODS:After ethical approval was obtained, 56 consecutive patients with ASD with severe PAH were included (7 men, 49 women; median age 50.5 years; mean ASD size 26.9 ± 4.6 mm). After 3 months of TMT, transcatheter closure was performed using F-ASO in patients with ratios of pulmonary to systemic blood flow ≥1.5. TMT was continued post-operatively together with 6 months of dual-antiplatelet therapy. The hemodynamic variables during baseline, TMT alone, and combined treatment with F-ASO were compared.RESULTS:After only TMT, systolic pulmonary arterial pressure (-14.5 mm Hg; p < 0.001), pulmonary vascular resistance (-3.9 Wood units; p < 0.001), and exercise capacity (+72.0 m; p < 0.001) improved. Ratio of pulmonary to systemic blood flow increased by 0.9 (p < 0.001), with adverse cardiac remodeling (right ventricular dimension +3.5 mm; p < 0.001). Closure with F-ASO (median size 34.0 mm) led to further decrease in systolic pulmonary artery pressure (-6.0 mm Hg; p < 0.001). Follow-up (median duration 10 months) revealed further improvement in exercise capacity (+60.5 m; p < 0.001), with favorable cardiac remodeling (right ventricular dimension -9.9 mm; p < 0.001). In addition, all fenestrations were stable (p = 0.699), with negligible shunt (median ratio of pulmonary to systemic blood flow 1.1) and no complications. One year later, pulmonary artery pressure was normalized in 8 of 19 patients, and PAH recurred in 5 patients after discontinuation of TMT.CONCLUSIONS:In patients with ASD and severe PAH, combination of F-ASO and TMT was a safe and effective procedure. Compared with TMT alone, the combined treatment further improved exercise capacity, with favorable cardiac remodeling.

11.3
1区

JACC. Cardiovascular interventions 2020

Fistula between the right pulmonary artery and the left atrium coexisting with a secundum-type atrial septal defect: An unusual case of cyanosis in a girl.

A fistula between the pulmonary artery (PA) and the left atrium (LA) is a rare congenital heart disease that usually presents with cyanosis, clubbing, and dyspnea, as well as the signs and symptoms of a right-to-left shunt. Herein, we report a 16-year-old girl with a fistula between the right PA and the LA. This type of fistula could lead to systemic desaturation. This patient also had an atrial septal defect of the secundum type and has been followed up without treatment. The clinical manifestations and treatment of fistulas located between the PA and LA are also reviewed in this report.

1.5
4区

Echocardiography (Mount Kisco, N.Y.) 2019

Off-label use of duct occluder in transcatheter closure of secundum atrial septal defect with no rim to right pulmonary vein.

OBJECTIVE:Transcatheter closure is usually contraindicated in secundum atrial septal defect with no rim to right pulmonary vein. The morphology of an atrial septal defect is special in these patients, and the off-label use of a duct occluder might make transcatheter closure possible with the assistance of a personalized heart model. However, the related data are absent. This study was performed to investigate the off-label use of a duct occluder in the transcatheter closure of an atrial septal defect with no right pulmonary vein rim.METHODS:Seven consecutive patients with an atrial septal defect (2 male/5 female; 40.1 ± 15.2 years) with no right pulmonary vein rim were referred for attempted transcatheter closure, and a personalized heart model was produced on the basis of multislice computed tomography images. With the elastic heart model, in vitro trial occlusion was performed with a duct occluder for preoperative evaluation, and the results were compared with postoperative outcomes.RESULTS:A single atrial septal defect was identified in 6 patients, and a double atrial septal defect was identified in another patient (1 atrial septal defect with no right pulmonary vein rim and 1 with sufficient surrounding rims). The size of the atrial septal defect was 13.4 ± 2.2 mm, and the in vitro balloon-stretched diameter was 20.2 ± 3.2 mm in the heart model. In vitro trial occlusion was achieved in all patients, and subsequent in vivo transcatheter closure was performed successfully with the duct occluder of the same size (24.3 ± 3.1 mm). During follow-up (1.57 ± 0.84 years), mild pericardial effusion was identified in 2 patients and disappeared within 3 months. No other complications occurred.CONCLUSIONS:By using a personalized heart model, the off-label use of a duct occluder is feasible and safe in the transcatheter closure of an atrial septal defect with no right pulmonary vein rim. Further research is required to evaluate the long-term outcomes.

6.0
1区

The Journal of thoracic and cardiovascular surgery 2019