Optimal treatment of tannic acid for the anti-calcification of bovine jugular veins and the underlying mechanism.

OBJECTIVES:To evaluate the effects of combined treatment with tannic acid and ferric ions on the biomechanical and anti-calcification properties of glutaraldehyde-fixed bovine jugular veins after xenografting.METHODS:Two-point bending test and uniaxial tensile test were used to evaluate the flexural and biomechanical properties; Subcutaneous implantation in rat and right ventricular outflow tract reconstruction of sheep were used to evaluate the anti-calcification effects; The performance of the graft in sheep models was evaluated every month after the surgery with echocardiography examination. Markers of macrophages, T lymphocytes, smooth muscle cell osteogenic differentiation and matrix metalloproteinases in sheep explants were detected by immunohistochemistry.RESULTS:The flexibility of the bovine jugular veins cotreated with ferric ions-tannic acid was improved while maintaining biomechanical properties and excellent anti-calcification effects. Echocardiography results showed that the grafts functioned well in the animals without stenosis or reflux of the valve. Immunohistochemical studies showed that the osteogenic differentiation marker (Runx2) was detected in calcified regions and colocalised with the SMC marker (α-SMA). Compared to the glutaraldehyde-treated samples, T-cell marker (CD3), matrix metalloproteinase-2 and 9 expressions were reduced in the ferric ions-tannic acid treated group.CONCLUSION:Ferric ions-tannic acid treatment can give the conduits better flexibility with excellent biomechanical properties and anti-calcification effects, making it a promising bovine jugular veins processing method.

1.7
4区
第一作者

The International journal of artificial organs 2023

Effect of valve leaflet surface patterning on valve hydrodynamic performance.

OBJECTIVE:We aimed to elucidate the effects of the micro-structure of the pyrolytic carbon for artificial heart valves on its hydrodynamic performance.METHODS:Bileaflet mechanical valves of GKS 23 and 29 A were randomly selected. According to ISO5840, mean transvalvular pressure (MPG), regurgitation fraction (RF), and effective orifice area (EOA) of valve were assessed. Then, parallel-groove pattern was constructed by laser etching on leaflet surface, and the valves were subjected again to the same test.RESULTS:Compared with before patterning at 2, 3.5, 5, and 7 L/min, the MPG of the valves in two specifications were higher, the EOA was larger in 23 A, but smaller in 29 A, and the RF was contrary to EOA. At 5 L/min, the RF in both specifications was lower after etching at 45 bpm. At 70 bpm however, the RF in 23 A decreased, in 29 A increased.CONCLUSION:The parallel-groove pattern on leaflet surface affected the hemodynamic performance of the valve prostheses.

1.7
4区
第一作者

The International journal of artificial organs 2023