张海龙
中国医学科学院阜外医院 核医学科
OBJECTIVE:Data involved the association between myocardial ischaemia and the outcome for unrevascularized coronary chronic total occlusion (CTO) patients were limited. The purpose of this study was to evaluate the predictive value of ischaemia detected by single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) for the adverse events in unrevascularized CTO patients. We further explored whether ischaemia generated from CTO vessel can independently predict the outcome.METHODS:Patients with at least one unrevascularized CTO on coronary angiography were enrolled in this study. Exercise stress/rest SPECT MPI was performed in all patients. All patients were then followed by telephone interview and reviewing of medical records.RESULTS:Patients with ischaemia experienced significantly higher rate of adverse events than non-ischaemia patients (40.7% vs 7.1%, P = 0.002). Ischaemia demonstrated on MPI [odds ratio (OR) = 7.656; 95% confidence interval (CI) 1.598-36.677; P = 0.011] was an independent predictor for adverse events. Moreover, CTO-ischaemia (OR = 5.466; 95% CI 1.015-29.420; P = 0.048), non-CTO ischaemia (OR = 29.174; 95% CI 3.245-262.322; P = 0.003), mixed-ischaemia (OR = 7.130, 95% CI 1.257-40.445; P = 0.027) were all independent predictors for outcome.CONCLUSION:Ischaemia demonstrated on MPI, especially CTO-ischaemia were independent predictors for the adverse events. SPECT MPI can aid to identify patients at risk of adverse events, who may benefit from subsequent CTO percutaneous coronary intervention.
Annals of nuclear medicine 2022
OBJECTS:Although balloon pulmonary angioplasty (BPA) has emerged as an alternative treatment option for chronic thromboembolic pulmonary hypertension (CTEPH), it is followed in some patients by residual PH. We studied the efficacy of BPA on pulmonary blood flow and the predictive value of ventilation/perfusion (V/Q) scanning.METHODS:We retrospectively reviewed the clinical database, which included patients diagnosed with CTEPH who had received BPA. All patients undergone V/Q scanning to quantify the extent of pulmonary perfusion abnormality before and after BPA. Pulmonary hemodynamics were assessed by right heart catheterization, and cardiac function and exercise capacity were evaluated at baseline and post-BPA. A total of 120 CTEPH patients were included for analysis.RESULTS:BPA significantly alleviated mean pulmonary arterial pressure (mPAP: 48.0 ± 12.9 mmHg vs 34.7 ± 10.3 mmHg, P < 0.001) and pulmonary vascular resistance (PVR: 8.8 ± 4.1 Wood units vs 5.2 ± 3.0 Wood units, P < 0.001), and improved cardiac function (N-terminal pro B-type natriuretic peptide: 1628.7 ± 2887.2 pg/mL vs 400.4 ± 669.3 pg/mL, P < 0.001) and exercise capacity (6-minute walking distance: 386 ± 122 m vs 461 ± 86 m, P < 0.001). The extent of pulmonary perfusion abnormality represented by the percentage of perfusion defects (PPDs%) was improved after BPA (50.1 ± 13.6 vs 35.6 ± 14.2, P < 0.001), with the right and inferior lung lobes benefitting the most. PPDs% < 35.5 at baseline and greater restoration of PPDs% after BPA (∆PPDs% > 20.6) were associated with a better response to BPA (PPDs% < 35.5: odds ratio [OR] 10.857, 95% confidence interval [95%CI] 1.393-84.635, P = 0.023; ∆PPDs% > 20.6: OR 1.035, 95% CI 1.002-1.068, P = 0.036).CONCLUSION:BPA significantly restored pulmonary blood flow, predominantly in the right and inferior lobes. V/Q scanning has the potential to predict the therapeutic response to BPA for CTEPH.
Annals of nuclear medicine 2022
Background Accurate methods for identifying obstructions in both large and small vessels are crucial for diagnosis and treatment of chronic thromboembolic pulmonary hypertension (CTEPH). Purpose To compare the performance of ventilation-perfusion (V/Q) scanning, V/Q SPECT, and CT pulmonary angiography (PA) in CTEPH by using digital subtraction PA as the reference standard. Materials and Methods This prospective study was conducted from January 2016 to January 2018. A total of 229 participants suspected of having CTEPH were evaluated with V/Q SPECT, V/Q planar scintigraphy, CT PA, and digital subtraction PA. Participants underwent all four procedures within 1 week. Differences in the diagnostic performance of V/Q SPECT, V/Q planar scintigraphy, and CT PA were evaluated with areas under the curve receiver operator curve, the McNemar test, and generalized estimating equations analysis. Results A total of 150 participants (mean age, 42 years ± 15 [standard deviation]; 99 women) were enrolled. Digital subtraction PA assessments confirmed CTEPH in 51 participants and indicated that 602 of 1020 lung segments (20 segments per participant) were obstructed. The three imaging methods showed high sensitivity (V/Q SPECT, 98%; V/Q planar scintigraphy, 98%; CT PA, 94%) and specificity (V/Q SPECT, 89%; V/Q planar scintigraphy, 91%; CT PA, 96%) (all P > .05). However, both V/Q scanning techniques were more sensitive (V/Q SPECT: 85%, P < .001 vs CT PA: 67%; V/Q planar scintigraphy: 83%, P < .001 vs CT PA: 67%), and less specific (V/Q planar scintigraphy: 51%, P = .03 vs CT PA: 60%; V/Q SPECT: 42%, P < .01 vs CT PA: 60%) than was CT PA for segmental analysis. Areas under the curve for CT PA, V/Q planar scintigraphy, and V/Q SPECT were 0.95, 0.95, and 0.94, respectively (all P > .05), for individual analysis, and 0.64, 0.67, and 0.64, respectively, by segment (V/Q planar scintigraphy vs V/Q SPECT, P = .02; V/Q planar scintigraphy vs CT PA, P = .08; V/Q SPECT vs CT PA, P = .94). Conclusion Ventilation-perfusion scanning was more sensitive and less specific than was CT pulmonary angiography for detecting vascular obstructions at the segmental pulmonary arterial level. © RSNA, 2020 See also the editorial by Swift and Rajaram in this issue.
Radiology 2020
OBJECTIVE:To assess the value of (99m)Tc-N-NOET ((99m)Tc-N-ethoxy-N-ethyl dithiocarbamato-nitrito) myocardial perfusion SPECT for the diagnosis of coronary artery disease.METHODS:A total of 42 patients [mean age (54 +/- 9) years, 35 men] with suspected chest pain were included in this study. 740 MBq of (99m)Tc-N-NOET was injected intravenously during bicycle exercise when the heart rate attained reached more than 85% of the expected maximum, or in cases of angina pectoris, severe arrhythmias and ischemic ST segment changes. (99m)Tc-N-NOET 740 MBq, SPECT myocardial imaging acquisitions were obtained at 15 minutes and 2 hours after (99m)Tc-N-NOET injection. Coronary angiography was performed in all patients.RESULTS:Coronary artery stenosis was detected in 26 patients and normal coronary angiography was shown in 16 patients. (99m)Tc-N-NOET myocardial perfusion imaging was abnormal in twenty-one patients out of the 26 patients with significant coronary artery stenosis (sensitivity, 81%); 14 out of 16 patients with normal angiography had a normal myocardial perfusion imaging (specificity, 88%). The positive predictive value, negative predictive value and predictive accuracy of (99m)Tc-N-NOET myocardial perfusion imaging for detection of CAD was 91%, 74% and 83%, respectively. The sensitivity of the imaging for detecting single vessel, double vessels and triple vessels disease were 60% (6/10), 86% (6/7) and 100% (9/9), respectively. There was mild (99m)Tc-N-NOET lung uptake in patients with coronary artery stenosis 15 minutes post (99m)Tc-N-NOET injection.CONCLUSION:SPECT myocardial perfusion imaging with (99m)Tc-N-NOET supplied an important diagnostic tool for detecting coronary artery disease. Lung uptake with stress (99m)Tc-N-NOET might be related to coronary artery disease.
Zhonghua xin xue guan bing za zhi 2007