张宗耀

中国医学科学院阜外医院 核医学科

Prognostic value of myocardial flow reserve derived by quantitative SPECT for patients with intermediate coronary stenoses.

BACKGROUND:Functional assessment of myocardial ischemia is critical for patients with intermediate coronary stenosis. As the diagnosis performance of absolute quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) by single-photon emission tomography (SPECT) has been proven, its prognostic value in patients with intermediate coronary stenosis remains to be evaluated.METHODS:Patients with one or more target lesions of ≥ 50% to ≤ 80% diameter stenoses on invasive coronary angiography were prospectively included in this study. All patients were scheduled for clinically indicated SPECT myocardial perfusion imaging (MPI) within 3 months and agreed to provide informed consent to participate in quantitative SPECT acquisitions to obtain MBF and MFR values. The primary endpoint was defined as a composite of the major adverse cardiac events (MACE): Cardiac death, myocardial infarction, late revascularization and heart failure or unstable angina-related rehospitalization.RESULTS:One hundred and nineteen patients (mean age 57 ± 8 years, 62.2% men) were included in the analysis. The average lumen stenosis of patients was 67.0 ± 10.4%. Over a median follow-up duration of 1408 days (interquartile range 1297-1666 days), 18 patients (15.1%) had MACE. Patients with impaired MFR (MFR < 2) had a significantly higher incidence of events than those with preserved MFR (MFR ≥ 2) in Kaplan-Meier survival analysis (Log-rank = 8.105, P = 0.004), while no significant difference was found between patients with normal relative perfusion and those with relative perfusion abnormalities (log-rank = 0.098, P > 0.05). In a multivariate Cox hazards analysis, the SPECT-derived MFR remained an independent predictor of MACE (HR 0.352, 95% CI 0.145-0.854, P = 0.021).CONCLUSIONS:In a cohort of patients with angiographic intermediate coronary lesions, SPECT-derived MFR was an independent predictor of prognosis.

2.4
4区

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2023

68Ga-FAPI PET/CT for molecular assessment of fibroblast activation in right heart in pulmonary arterial hypertension: a single-center, pilot study.

BACKGROUND:Positron emission tomography (PET) imaging with radiolabeled fibroblasts activation protein inhibitor (FAPI) provides the opportunity to directly visualize fibrosis. This study aimed to investigate the feasibility of 68Ga-FAPI PET imaging in assessing right ventricular (RV) fibrotic remodeling and the relationship between FAPI uptake with parameters of pulmonary hemodynamics and cardiac function in pulmonary arterial hypertension (PAH) patients.METHODS:In this pilot study, sixteen PAH patients were enrolled to participate in cardiac 68Ga-FAPI PET/CT imaging. All patients underwent right heart catheterization and echocardiography for assessment of pulmonary hemodynamics and cardiac function within seven days. Cardiac FAPI uptake was visually assessed and quantified as maximum standardized uptake value (SUVmax).RESULTS:Twelve PAH patients exhibited FAPI uptake in RV free wall and insertion point. The overall activity of FAPI accumulated in the RV free wall (SUVmax: 2.5 ± 1.8, P < 0.001) and insertion point (SUVmax:2.5 ± 1.7, P < 0.001) was significantly upregulated compared to left ventricle (SUVmax:1.5 ± 0.5). Patients with tricuspid annular plane systolic excursion (TAPSE) < 17 mm presented significantly higher uptake than those with TAPSE ≥ 17 mm in both RV free wall (SUVmax: 3.4 ± 1.9 vs 1.7 ± 1.1, P = 0.010) and insertion point (SUVmax: 3.4 ± 1.9 vs 1.6 ± 0.7, P = 0.028), indicating RV uptake of FAPI was associated with RV dysfunction. There was significant positive correlation between cardiac FAPI uptake and total pulmonary resistance and the level of N-terminal pro b-type natriuretic peptide.CONCLUSIONS:68Ga-FAPI PET/CT imaging is feasible to directly visualize fibrotic remodeling of RV in patients with PAH.

2.4
4区

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2023

68Ga-FAPI right heart uptake in a patient with idiopathic pulmonary arterial hypertension.

2.4
4区

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2022

Assessment of cardiac amyloidosis with 99mTc-pyrophosphate (PYP) quantitative SPECT.

BACKGROUND:99mTc-PYP scintigraphy provides differential diagnosis of ATTR cardiomyopathy (ATTR-CM) from light chain cardiac amyloidosis and other myocardial disorders without biopsy. This study was aimed to assess the diagnostic feasibility and the operator reproducibility of 99mTc-PYP quantitative SPECT.METHOD:Thirty-seven consecutive patients who underwent a 99mTc-PYP thorax planar scan followed by SPECT and CT scans to diagnose suspected ATTR-CM were enrolled. For the quantitative SPECT, phantom studies were initially performed to determine the image conversion factor (ICF) and partial volume correction (PVC) factor to recover 99mTc-PYP activity concentration in the myocardium for calculating the standardized uptake value (SUV) (unit: g/ml). SUVmax was compared among groups of ATTR-CM, AL cardiac amyloidosis, and other pathogens (others) and among categories of Perugini visual scores (grades 0-3). The intra- and inter-operator reproducibility of quantitative SPECT was verified, and the corresponded repeatability coefficient (RPC) was calculated.RESULTS:The ICF was 79,327 Bq/ml to convert count rate in pixel to 99mTc activity concentration. PVC factor as a function of the measured activity concentration ratio in the myocardium and blood-pool was [y = 1.424 × (1 - exp(- 0.759 × x)) + 0.104]. SUVmax of ATTR-CM (7.50 ± 2.68) was significantly higher than those of AL (1.96 ± 0.35) and others (2.00 ± 0.74) (all p < 0.05). SUVmax of grade 3 (8.95 ± 1.89) and grade 2 (4.71 ± 0.23) were also significantly higher than those of grade 1 (1.92 ± 0.31) and grade 0 (1.59 ± 0.39) (all p < 0.05). Correlation coefficient (R2) of SUVmax reached 0.966 to 0.978 with only small systematic difference (intra = - 0.14; inter = - 0.23) between two repeated measurements. Intra- and inter-operator RPCs were 0.688 and 0.877.CONCLUSIONS:99mTc-PYP quantitative SPECT integrated with adjustable PVC factors is feasible to quantitatively and objectively assess the burden of cardiac amyloidosis for diagnosis of ATTR-CM.

4.0
2区

EJNMMI physics 2021

Comparison of V/Q SPECT and CT Angiography for the Diagnosis of Chronic Thromboembolic Pulmonary Hypertension.

Background Accurate methods for identifying obstructions in both large and small vessels are crucial for diagnosis and treatment of chronic thromboembolic pulmonary hypertension (CTEPH). Purpose To compare the performance of ventilation-perfusion (V/Q) scanning, V/Q SPECT, and CT pulmonary angiography (PA) in CTEPH by using digital subtraction PA as the reference standard. Materials and Methods This prospective study was conducted from January 2016 to January 2018. A total of 229 participants suspected of having CTEPH were evaluated with V/Q SPECT, V/Q planar scintigraphy, CT PA, and digital subtraction PA. Participants underwent all four procedures within 1 week. Differences in the diagnostic performance of V/Q SPECT, V/Q planar scintigraphy, and CT PA were evaluated with areas under the curve receiver operator curve, the McNemar test, and generalized estimating equations analysis. Results A total of 150 participants (mean age, 42 years ± 15 [standard deviation]; 99 women) were enrolled. Digital subtraction PA assessments confirmed CTEPH in 51 participants and indicated that 602 of 1020 lung segments (20 segments per participant) were obstructed. The three imaging methods showed high sensitivity (V/Q SPECT, 98%; V/Q planar scintigraphy, 98%; CT PA, 94%) and specificity (V/Q SPECT, 89%; V/Q planar scintigraphy, 91%; CT PA, 96%) (all P > .05). However, both V/Q scanning techniques were more sensitive (V/Q SPECT: 85%, P < .001 vs CT PA: 67%; V/Q planar scintigraphy: 83%, P < .001 vs CT PA: 67%), and less specific (V/Q planar scintigraphy: 51%, P = .03 vs CT PA: 60%; V/Q SPECT: 42%, P < .01 vs CT PA: 60%) than was CT PA for segmental analysis. Areas under the curve for CT PA, V/Q planar scintigraphy, and V/Q SPECT were 0.95, 0.95, and 0.94, respectively (all P > .05), for individual analysis, and 0.64, 0.67, and 0.64, respectively, by segment (V/Q planar scintigraphy vs V/Q SPECT, P = .02; V/Q planar scintigraphy vs CT PA, P = .08; V/Q SPECT vs CT PA, P = .94). Conclusion Ventilation-perfusion scanning was more sensitive and less specific than was CT pulmonary angiography for detecting vascular obstructions at the segmental pulmonary arterial level. © RSNA, 2020 See also the editorial by Swift and Rajaram in this issue.

19.7
1区

Radiology 2020

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure.

AIM:The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF).METHODS:Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting 99mTc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and 18F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually.RESULTS:There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT.CONCLUSION:CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

2.4
4区

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 2019