王墨扬
中国医学科学院阜外医院 心血管内科
BACKGROUND:Stress hyperglycemia ratio (SHR) has recently been recognized as a novel biomarker that accurately reflects acute hyperglycemia status and is associated with poor prognosis of heart failure. We evaluated the relationship between SHR and clinical outcomes in patients with severe aortic stenosis receiving transcatheter aortic valve replacement (TAVR).METHODS:There were 582 patients with severe native aortic stenosis who underwent TAVR consecutively enrolled in the study. The formula used to determine SHR was as follows: admission blood glucose (mmol/L)/(1.59×HbA1c[%]-2.59). The primary endpoint was defined as all-cause mortality, while secondary endpoints included a composite of cardiovascular mortality or readmission for heart failure, and major adverse cardiovascular events (MACE) including cardiovascular mortality, non-fatal myocardial infarction, and non-fatal stroke. Multivariable Cox regression and restricted cubic spline analysis were employed to assess the relationship between SHR and endpoints, with hazard ratios (HRs) and 95% confidence intervals (CIs).RESULTS:During a median follow-up of 3.9 years, a total of 130 cases (22.3%) of all-cause mortality were recorded. Results from the restricted cubic spline analysis indicated a linear association between SHR and all endpoints (p for non-linearity > 0.05), even after adjustment for other confounding factors. Per 0.1 unit increase in SHR was associated with a 12% (adjusted HR: 1.12, 95% CI: 1.04-1.21) higher incidence of the primary endpoint, a 12% (adjusted HR: 1.12, 95% CI: 1.02-1.22) higher incidence of cardiovascular mortality or readmission for heart failure, and a 12% (adjusted HR: 1.12, 95% CI: 1.01-1.23) higher incidence of MACE. Subgroup analysis revealed that SHR had a significant interaction with diabetes mellitus with regard to the risk of all-cause mortality (p for interaction: 0.042). Kaplan-Meier survival analysis showed that there were significant differences in the incidence of all endpoints between the two groups with 0.944 as the optimal binary cutoff point of SHR (all log-rank test: p < 0.05).CONCLUSIONS:Our study indicates linear relationships of SHR with the risk of all-cause mortality, cardiovascular mortality or readmission for heart failure, and MACE in patients with severe aortic stenosis receiving TAVR after a median follow-up of 3.9 years. Patients with an SHR exceeding 0.944 had a poorer prognosis compared to those with lower SHR values.
Cardiovascular diabetology 2024
Background:Clinical evidence of transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve was relatively scarce.Aims:Our goal was to explore determinants of device success after transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve morphology.Methods:In this retrospective multicenter analysis, we included 59 patients with symptomatic severe aortic stenosis with type-0 bicuspid aortic valve morphology who underwent transcatheter aortic valve replacement. Type-0 bicuspid aortic valve was identified with multidetector computed tomography scans. The technical success rate was 89.8%, and the device success rate was 81.4%. Patients were divided into a device success group and a device failure group according to Valve Academic Research Consortium- 3 criteria.Results:When we compared the two groups, we found that the ellipticity index of the aortic root and the presence of bulky calcifications at the commissure were statistically different (ellipticity index 35.7 ± 1.7 vs. 29.7 ± 1.1, p = 0.018; bulky calcification at the commissure, 54.5% vs. 4.5%, p < 0.001). Further multivariate logistic analysis showed that bulky calcification at the commissure had a negative correlation with device success (odds ratio 0.030, 95% confidence interval 0.003-0.285, p = 0.002). Yet there was no statistical correlation between the ellipticity index and device success (odds ratio 0.818, 95% confidence interval 0.667-1.003, p = 0.053).Conclusions:The presence of bulky calcifications at the commissure is negatively correlated with device success after transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve.
Frontiers in cardiovascular medicine 2023
INTRODUCTION:The strategy for initiating antithrombotic therapy to prevent bioprosthetic valve thrombosis (BPVT) after transcatheter aortic valve replacement (TAVR) remains uncertain. There is still lacking evidence on the efficacy and safety of early 6 months usage of single-antiplatelet therapy (SAPT) or oral anticoagulant (OAC) after TAVR in patients without anticoagulant indications.METHODS AND ANALYSIS:This is a multicentre, randomised controlled, open-label trial, and 650 patients undergoing TAVR from 13 top TAVR centres in China will be recruited. Each eligible participant will be randomly assigned to two groups (1:1 ratio) as (1) SAPT (aspirin 75-100 mg for 6 months) group or (2) OAC group (warfarin, therapeutic international normalised ratio at 1.8-2.5 for 6 months), both followed by sequential aspirin 75-100 mg for 6 months. Participants in both groups will be invited for three follow-up visits of 1, 6 and 12 months after discharge. We will use both the net clinical benefit endpoint (composite of all-cause mortality, myocardial infarction, stroke/transient ischaemic attacks, peripheral artery thrombosis, intracardiac thrombosis and major bleeding and disabling or life-threatening bleeding) and the BPVT endpoint evaluated by four-dimensional CT as our primary endpoints. P value of <0.05 of two-sided test will be considered statistically significant.ETHICS AND DISSEMINATION:The present study was approved by the Institutional Review Boards at Fuwai Hospital, National Center for Cardiovascular Diseases of China (Approval No. 2023-1947). All patients will be informed of the details of the study and will sign an informed consent prior to inclusion in the study. Results of this study will be published in a peer-reviewed journal.TRIAL REGISTRATION NUMBER:NCT05375474.
BMJ open 2023
BACKGROUND:Pre-procedural computed tomography (CT) imaging assessment of the aortic valvular complex (AVC) is essential for the success of transcatheter aortic valve replacement (TAVR). However, pre-TAVR assessment is a time-intensive process, and the visual assessment of anatomical structures at the AVC shows interobserver variability. This study aimed to develop and validate a deep learning-based algorithm for pre-TAVR CT assessment and anatomical risk factor detection.METHODS:This retrospective, multicentre study used AVC CT scans to develop a deep learning-based, fully automated algorithm, which was then internally and externally validated. After loading CT scans into the algorithm, it automatically assessed the essential anatomical structure data required for TAVR planning. CT scans of 1252 TAVR candidates continuously enrolled from Fuwai Hospital were used to establish training and internal validation datasets, while CT scans of 100 patients with aortic valve disease across 19 Chinese hospitals served as an external validation dataset. The validation focused on segmentation performance, localisation and measurement accuracy of key anatomical structures, detection ability of specific anatomical risk factors, and improvement in assessment efficiency.FINDINGS:Relative to senior observers, our algorithm achieved significant consistent performance with remarkable accuracy, efficiency and ease in segmentation, localisation, and the assessment of the aortic annulus perimeter-derived diameter, and other basic planes, coronary ostia height, calcification volume, and aortic angle. The intraclass correlation coefficient values for the algorithm in the internal and external validation datasets were up to 0.998 (95% confidence interval 0.998-0.998), respectively. Furthermore, the algorithm demonstrated high alignment in detecting specific anatomical risk factors, with accuracy, sensitivity, and specificity up to 0.989 (95% CI 0.973-0.996), 0.979 (95% CI 0.936-0.995), 0.986 (95% CI 0.945-0.998), respectively.INTERPRETATION:Our algorithm efficiently performs pre-TAVR assessments by using AVC CT imaging with accuracy comparable to senior observers, potentially improving TAVR planning in clinical practice.FUNDING:National Key R&D Program of China (2020YFC2008100), CAMS Innovation Fund for Medical Sciences (2022-I2M-C&T-B-044).
EBioMedicine 2023
This study analyzed computed tomography (CT) measurement characteristics and anatomical classifications based on transcatheter aortic valve replacement (TAVR) in patients with aortic regurgitation (AR) to establish a preliminary summary of CT anatomical characteristics and to design a novel self-expanding transcatheter heart valve (THV). This single-center retrospective cohort study included 136 patients diagnosed with moderate-to-severe AR at Fuwai Hospital from July 2017 to April 2022. Patients were classified into four anatomical classifications according to dual-anchoring multiplanar measurement of where THV anchoring took place. Types 1-3 were considered candidates for TAVR, whereas type 4 was not. Among 136 patients with AR, there were 117 (86.0%) tricuspid, 14 bicuspid, and five quadricuspid valves. Dual-anchoring multiplanar measurement showed that the annulus was smaller than left ventricular outflow tract (LVOT) at 2, 4, 6, 8, and 10 mm on the annulus. The ascending aorta (AA) 40 mm was wider than AA 30 mm and AA 35 mm, but narrower than AA 45 mm and AA 50 mm. For 10% oversize of the THV, the proportions of the annulus, LVOT, and AA unable to meet the diameter were 22.8%, 37.5%, and 50.0%, respectively, and the proportions of anatomical classification types 1-4 were 32.4%, 5.9%, 30.1%, and 31.6%, respectively. The novel THV could significantly improve the type 1 proportion (88.2%). Existing THVs cannot meet the anatomical characteristics of patients with AR. Conversely, based on anatomical characteristics, the novel THV could theoretically facilitate TAVR.
The international journal of cardiovascular imaging 2023
INTRODUCTION:Chronic severe aortic regurgitation (AR) has a poor long-term prognosis, especially among old-age patients. Considering their advancing age, the surgical approach of aortic valve replacement may not always be the best alternative modality of treatment in such patients. Therefore, this study's primary goal was to provide an initial summary of the medium- and short-term clinical effectiveness of transcatheter aortic valve replacement (TAVR) guided by accurate multi-detector computed tomography (MDCT) measurements in patients with severe and chronic AR, especially in elderly patients.METHODS:The study enrolled retrospectively and prospectively patients diagnosed with severe AR who eventually underwent TAVR procedure from January 2019 to September 2022 at Fuwai cardiovascular Hospital, Beijing. Baseline information, MDCT measurements, anatomical classification, perioperative, and 1-year follow-up outcomes were collected and analyzed. Based on a novel anatomical categorization and dual anchoring theory, patients were divided into four categories according to the level of anchoring area. Type 1, 2, and 3 patients (with at least two anchoring regions) will receive TAVR with a transcatheter heart valve (THV), but Type 4 patients (with zero or one anchoring location) will be deemed unsuitable for TAVR and will instead receive medical care (retrospectively enrolled patients who already underwent TAVR are an exception).RESULTS:The mean age of the 37 patients with severe chronic AR was 73.1 ± 8.7 years, and 23 patients (62.2%) were male. The American Association of Thoracic Surgeons' score was 8.6 ± 2.1%. The MDCT anatomical classification included 17 cases of type 1 (45.9%), 3 cases of type 2 (8.1%), 13 cases of type 3 (35.1%), and 4 cases of Type 4 (10.8%). The VitaFlow valve (MicroPort, Shanghai, China) was implanted in 19 patients (51.3%), while the Venus A valve (Venus MedTech, Hangzhou, China) was implanted in 18 patients (48.6%). Immediate TAVR procedural and device success rates were 86.5% and 67.6%, respectively, while eight cases (21.6%) required THV-in-THV implantation, and nine cases (24.3%) required permanent pacemaker implantation. Univariate regression analysis revealed that the major factors affecting TAVR device failure were sinotubular junction diameter, THV type, and MDCT anatomical classification (p < 0.05). Compared with the baseline, the left ventricular ejection fraction gradually increased, while the left ventricular end-diastolic diameter remained small, and the N-terminal-pro hormone B-type natriuretic peptide level significantly decreased within one year.CONCLUSION:According to the results of our study, TAVR with a self-expanding THV is safe and feasible for patients with chronic severe AR, particularly for those who meet the criteria for the appropriate MDCT anatomical classification with intact dual aortic anchors, and it has a significant clinical effect for at least a year.
Journal of clinical medicine 2023
Background:The association between prior percutaneous coronary intervention (PCI) and prognosis after coronary artery bypass grafting (CABG) remains uncertain. We aimed to evaluate the aforementioned association in a meta-analysis.Methods:PubMed, Cochrane's Library, and Embase databases were searched for potential studies. A random-effects model was used for the meta-analysis. Meta-regression was performed to evaluate the influence of study characteristics on the outcomes.Results:Thirty-six follow-up studies with 308,284 patients were included, and 40,892 (13.3%) patients had prior PCI. Pooled results showed that prior PCI was associated with higher risks of early (in-hospital or within 1 month) all-cause mortality [odds ratio (OR): 1.26, 95% confidence interval (CI): 1.11-1.44, p = 0.003; I 2 = 64%] and major adverse cardiovascular events (MACEs; OR: 1.36, 95% CI: 1.12-1.66, p = 0.002, I 2 = 79%), but not with late (follow-up durations from 1 to 13 years) mortality (OR: 1.03, 95% CI: 0.95-1.13, p = 0.44, I 2 = 46%) or MACEs (OR: 1.03, 95% CI: 0.97-1.09, p = 0.38, I 2 = 0%). Meta-regression showed that the study characteristics of patient number, age, sex, diabetic status, and proportion of patients with prior PCI did not affect the outcomes. Sensitivity analyses limited to multivariate studies excluding patients with acute PCI failure showed similar results (early mortality, OR: 1.25, p = 0.003; early MACE, OR: 1.50, p = 0.001; late mortality, OR: 1.03, p = 0.70).Conclusion:The current evidence, mostly from retrospective observational studies, suggests that prior PCI is related to poor early clinical outcomes, but not to late clinical outcomes, after CABG.
Therapeutic advances in chronic disease 2022
BACKGROUND:The study aimed to describe the aortic valve morphology in Chinese patients underwent transcatheter aortic valve replacement (TAVR) for symptomatic severe aortic stenosis (AS), and the impact of sizing strategies and related procedural outcomes.METHODS:Patients with severe AS who underwent TAVR were consecutively enrolled from 2012 to 2019. The anatomy and morphology of the aortic root were assessed. "Downsize" strategy was preformed when patients had complex morphology. The clinical outcomes of patients who performed downsize strategy were compared with those received annular sizing strategy. The primary outcome was device success rate, and secondary outcomes included Valve Academic Research Consortium-3 clinical outcomes variables based on 1-year follow-up.RESULTS:A total of 293 patients were enrolled. Among them, 95 patients (32.4%) had bicuspid aortic valve. The calcium volume (Hounsfield Unit-850) of aortic root was 449.90 (243.15-782.15) mm 3 . Calcium is distributed mostly on the leaflet level. Downsize strategy was performed in 204 patients (69.6%). Compared with the patients who performed annular sizing strategy, those received downsize strategy achieved a similar device success rate (82.0% [73] vs . 83.3% [170], P = 0.79). Aortic valve gradients (downsize strategy group vs . annular sizing group, 11.28 mmHg vs. 11.88 mmHg, P = 0.64) and percentages of patients with moderate or severe paravalvular regurgitation 2.0% (4/204) vs . 4.5% (4/89), P = 0.21) were similar in the two groups at 30 days after TAVR. These echocardiographic results were sustainable for one year.CONCLUSIONS:Chinese TAVR patients have more prevalent bicuspid morphology and large calcium volume of aortic root. Calcium is distributed mostly on the leaflet level. Compare with annular sizing strategy, downsize strategy provided a non-inferior device success rate and transcatheter heart valve hemodynamic performance in self-expanding TAVR procedure.
Chinese medical journal 2022
Background: Aortic stenosis (AS) increases left ventricular afterload, leading to cardiac damage and heart failure (HF). Transcatheter aortic valve replacement (TAVR) is an effective therapy for AS. No inotropic agents including levosimendan have been evaluated in patients undergoing TAVR. Methods: A total of 285 patients underwent TAVR between 2014 and 2019; 210 were included in the matched analysis and 105 received 0.1 μg/kg body weight/min levosimendan immediately after the prosthesis had been successfully implanted. Medical history, laboratory tests, and echocardiography results were analyzed. Endpoints including 2-year all-cause mortality, stroke, or HF-related hospitalization, and a combination of the above were analyzed by Cox proportional hazard models. Results: The levosimendan group had no difference in 2-year mortality compared with the control group (hazard ratio [HR]: 0.603, 95% confidence interval [CI]: 0.197-1.844; p = 0.375). However, levosimendan reduced stroke or HF-related hospitalization (HR: 0.346; 95% CI: 0.135-0.884; p = 0.027) and the combined endpoint (HR: 0.459, 95% CI: 0.215-0.980; p = 0.044). After adjusting for multiple variants, levosimendan still reduced stroke or HF-related hospitalization (HR: 0.346, 95% CI: 0.134-0.944; p = 0.038). Conclusion: Prophylactic levosimendan administration immediately after valve implantation in patients undergoing TAVR can reduce stroke or HF-related hospitalization but does not lower all-cause mortality.
Frontiers in pharmacology 2022
BACKGROUND:The success of transcatheter aortic valve replacement (TAVR) in native aortic regurgitation (AR) is limited by the absence of calcified anchoring structures. We sought to evaluate transfemoral TAVR in patients with native AR using a novel aortic root imaging classification.METHODS:From March to November 2021, 81 patients with severe AR were prospectively enrolled in 2 cardiac centers in China. All were evaluated using multidetector computed tomography (MDCT) and classified into 4 anatomic types in reference to transcatheter heart valve (THV) anchoring: Type 1: anchoring at the left ventricular outflow tract (LVOT), annulus, and ascending aorta (AA); Type 2: anchoring at the annulus and AA; Type 3: anchoring at the annulus and LVOT; and Type 4: anchoring at only 1 level or none at all. Based on the dual-anchoring strategy, patients with Types 1-3 were considered TAVR candidates. Procedural and 30-day outcomes were assessed according to Valve Academic Research Consortium-3 definitions.RESULTS:TAVR was performed in 32 (39.5%) patients (71.9 ± 8.0 years of age, 71.9% were male) using 2 self-expanding THVs. Types 1, 2, and 3 comprised 13 (40.6%), 11 (34.4%), and 8 (25.0%) cases, respectively. The procedural and device success rates were 100% and 93.8%, respectively, with 2 THV migration. Eight patients (25.0%) required a permanent pacemaker, and 2 (6.3%) developed moderate paravalvular leaks. No deaths or other major complications occurred during the study.CONCLUSIONS:The novel anatomic classification and dual-anchoring strategy were associated with a high procedural success rate with favorable short-term safety and clinical outcomes.
Echocardiography (Mount Kisco, N.Y.) 2022