Propensity-matched comparison of balloon-expandable and self-expanding valves for transcatheter aortic valve replacement in a Chinese population.

Background:Balloon-expandable valves (BEV) and self-expanding valves (SEV) for transcatheter aortic valve replacement (TAVR) have shown promising results in Western populations. Herein, we comparatively evaluated their hemodynamics and early clinical outcomes in a Chinese population.Methods:One hundred seventy-eight patients with symptomatic aortic stenosis who had undergone transfemoral TAVR using SEV (n=153; Venus-A, 97; VitaFlow, 56) or BEV (n=25; Sapien3) from September 2020 to April 2021 were retrospectively enrolled, and 25 pairs were propensity-score matched for 10 baseline variables. The primary study outcomes were aortic valve hemodynamics and postoperative complications at discharge and 3-month follow-up.Results:TAVR was successful in all patients. Compared with SEV group, the BEV group had similarly distributed baseline characteristics, procedural time, hospital stay, new pacemaker implantation, and paravalvular regurgitation grade. We also observed that the BEV group had lower rates of balloon pre-dilation (60% vs. 92%, P=0.018), post-dilation (0 vs. 20%, P=0.050) and second valve implantation (0 vs. 24%, P=0.022); higher mean transaortic gradient (14.3±6.1 vs. 10.8±4.9, P=0.030) and proportion of patients with elevated gradients (20% vs. 0, P=0.050) at discharge; and similar rehospitalization, mean transaortic gradient, new pacemaker implantation, and paravalvular regurgitation grade than the SEV group at the 3-month follow-up. There were no deaths in either group. However, the proportion of patients with elevated gradients in SEV group was higher at 3 months than before discharge (24% vs. 0, P=0.022).Conclusions:BEV and SEV for transfemoral TAVR appear comparably safe and effective, with high device success and favorable 3-month clinical outcomes. However, the transaortic gradient and new pacemaker implantation in the SEV group increased during follow-up, warranting larger studies with longer-term follow-up.

4区

Annals of translational medicine 2022

Long-Term Outcomes of Patients with Self-Expandable Transcatheter Heart Valve Embolized in the Aorta.

This study assesses the long-term outcomes of patients who suffered from self-expandable transcatheter heart valve (THV) embolized in the aorta in transcatheter aortic valve implantation (TAVI).We retrospectively reviewed the patients with self-expandable THV embolized in the aorta. Follow-up computed tomography was performed to assess the THV migration, struct fractures, and device-related aortic complications.Of the 539 TAVI patients, 11 suffered from self-expandable THV embolized in the aorta. Two patients underwent open-heart surgery to remove the embolized THVs in the ascending aorta. Embolized THVs were repositioned in the aortic arch distal to the left subclavian artery (n = 3) and the thoracic descending aorta (n = 6). Three patients died during a median follow-up time of 40 months. The remaining eight survivors presented with New York Heart Association functional class I or II at the last follow-up. Degeneration of embolized prostheses with thick leaflets and rolled cusp edges was observed in three patients. There was no evidence of valve migration, strut fracture, prosthesis-associated aortic complication, and thrombosis attached on embolized valve for all patients with THVs repositioned in the aorta.Self-expandable THV embolization can be effectively managed in TAVI. Although some embolized valves exhibited leaflet degeneration, the long-term safety of repositioning embolized self-expandable THV in the aorta is assured.

1.5
4区

International heart journal 2021

Application of the descending branch of the lateral circumflex femoral artery in coronary artery bypass grafting.

OBJECTIVE:To investigate a technical method for harvesting and using the descending branch of the lateral circumflex femoral artery (DLCFA) in coronary artery bypass grafting (CABG).METHODS:Between January 2017 and January 2019, 40 patients (36 in the planed selection group and 4 in the temporary decision group) with mean age of 49.1 ± 7.5 years received DLCFA as an arterial conduit in CABG. In all patients, the DLCFA was successfully harvested via an anterior thigh incision. Depending on the location of the target vessel, the DLCFA was used as a free graft or a composite graft.RESULTS:Of the 44 patients in the planned selection group, DLCFA harvesting was abandoned in 8 patients because computed tomographic angiography revealed anatomical variation or stenosis of the superficial femoral artery. Of the 5 patients in the temporary decision group, harvesting was abandoned in 1 because of short length and thin caliber. On an average, 3.7 ± 0.9 distal anastomoses were created during CABG, with no adverse effects. The length of the harvested DLCFA was 9.9 ± 1.7 cm, with an average proximal lumen diameter of 3.4 ± 0.7 mm. The DLCFA was used as a free graft in 26 patients and as a "Y"-shape composite graft in 14 patients. Total arterial CABG was performed in 75% of the patients.CONCLUSIONS:The DLCFA is an alternative conduit for CABG. It can be harvested easily and safely. However, preoperative computed tomographic angiography examination is necessary for the smooth application of the DLCFA, and an appropriate strategy for graft establishment should be considered.

6.0
1区

The Journal of thoracic and cardiovascular surgery 2021

Comparison of Procedural and 1-Year Clinical Results of Transcatheter Aortic Valve Implantation Using Prostheses with Different Design of Support Frame.

Our study aimed to investigate whether the frame design of transcatheter heart valve (THV) affects the procedural and clinical results of transcatheter aortic valve implantation (TAVI).We retrospectively reviewed 163 patients with aortic stenosis who underwent TAVI using different types of THV (Edwards SAPIEN, n = 31; Venus-A, n = 63; and J-Valve, n = 69). The procedural outcomes and follow-up results for 1-year were compared among groups.The patients who underwent TAVI using J-Valve had a higher mean transaortic pressure gradient than those using SAPIEN or Venus-A after TAVI (1-year follow-up; P = 0.017, P < 0.001, respectively), whereas no difference was observed between the patients with SAPIEN and Venus-A prosthesis (P = 0.150). The incidence of permanent pacemaker implantation was highest in patients with Venus-A (19.0%), followed by SAPIEN (9.7%), and lowest in J-Valve (4.3%) (P = 0.025). No difference was observed in the 30-day mortality rate among the groups (P = 1.000). Moreover, Kaplan-Meier survival analysis revealed that there was no significant difference in the 1-year cumulative patient survival rate among three patient cohorts (log-rank, P = 0.850).The frame design of THVs could affect the valve-related hemodynamics and the incidence of permanent pacemaker implantation in TAVI, whereas it did not influence the survival rate of TAVI patients during 1-year follow-up period. All three THVs provided a convincing short-term outcome for TAVI patients.

1.5
4区

International heart journal 2020