徐仲英
中国医学科学院阜外医院 心血管内科
BACKGROUND:Coronary arteries drain into the left ventricle, known as coronary-left ventricular fistula (CLVF), an extremely rare anomalous coronary artery disease. Little is known about the outcomes following transcatheter closure (TC) or surgical closure (SC) of CLVF.METHOD:This was a single-center retrospective study including 42 consecutive patients who underwent either the TC or SC procedure from January 2011 to December 2021. The baseline and anatomic characteristics of the fistulas, procedural outcomes, and late outcomes were summarized and analyzed.RESULTS:The mean age was 31.6 ± 16.2 years, with 28 male patients (66.7%). Fifteen patients underwent SC group and the remaining received TC group. There were no differences in age, comorbidities, clinical presentations, and anatomic characteristics between the 2 groups. The procedural success rate was similar (93.3% vs. 85.2%, P = 0.639) without operative and in-hospital mortality in both groups. Notably, patients who underwent TC had a significantly shorter postoperative in-hospital length of stay (2.11 ± 1.49 vs. 7.73 ± 2.37 days, P<0.001). The median follow-up time was 4.6 years (2.5-5.7 years, TC group) and 3.98 years (0.42-7.15 years, SC group), respectively. No difference was observed in the incidence of recanalization of the fistula (7.4% vs. 6.7%, P = 1) and myocardial infarction (0% vs. 0%). Cerebral infarction due to discontinuation of anticoagulants happened to two patients in the TC group. Importantly, thrombotic occlusion of the fistulous tract with patent parent coronary artery was found in 7 patients of the TC group.CONCLUSION:Both transcatheter and SC are safe and effective for patients with CLVF. Thrombotic occlusion is a noteworthy late complication, and its presence indicates the use of anticoagulants lifelong.
Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese 2023
(1) Background: the indications for transcatheter closure of large patent ductus arteriosus (PDA) with severe pulmonary hypertension (PH) are still unclear, and scholars have not fully elucidated the factors that affect PH prognosis. (2) Methods: we retrospectively enrolled 134 consecutive patients with a PDA diameter ≥10 mm or a ratio of PDA and aortic >0.5. We collected clinical data to explore the factors affecting follow-up PH. (3) Results: 134 patients (mean age 35.04 ± 10.23 years; 98 women) successfully underwent a transcatheter closure, and all patients had a mean pulmonary artery pressure (mPAP) >50 mmHg. Five procedures were deemed to have failed because their mPAP did not decrease, and the patients experienced uncomfortable symptoms after the trial occlusion. The average occluder (pulmonary end) size was almost twice the PDA diameter (22.33 ± 4.81 mm vs. 11.69 ± 2.18 mm). Left ventricular end-diastolic dimension (LVEDD), mPAP, and left ventricular ejection fraction (LVEF) significantly reduced after the occlusion, and LVEF recovered during the follow-up period. In total, 42 of the 78 patients with total pulmonary resistance >4 Wood Units experienced clinical outcomes, and all of them had PH in the follow-up, while 10 of them had heart failure, and 4 were hospitalized again because of PH. The results of a logistic regression analysis revealed that the postoperative mPAP had an independent risk factor (odds ratio = 1.069, 95% confidence interval: 1.003 to 1.140, p = 0.040) with a receiver operating characteristic curve cut-off value of 35.5 mmHg (p < 0.001). (4) Conclusions: performing a transcatheter closure of large patent ductus arteriosus is feasible, and postoperative mPAP was a risk factor that affected the follow-up PH. Patients with a postoperative mPAP >35.5 mmHg should be considered for targeted medical therapy or should undergo right heart catheterization again after the occlusion.
Journal of clinical medicine 2023
Background:Transcatheter closure of inferior sinus venosus defect (ISVD) is still contraindication. To explore whether transcatheter closure with patent ductus arteriosus (PDA) occluders is possible for ISVD.Methods:From June 2014 to March 2021, 12 patients were recruited diagnosed as <25 mm ISVD. The three-dimensional printing (3DP) heart model was produced based on multi-slice computed tomography (MSCT) scans. Preoperative closure simulation was planned on the personalized 3D model for each patient. Follow-up including electrocardiography (ECG), transthoracic echocardiography (TTE), and X-ray was traced.Results:3DP models of 12 patients were successfully printed. Twelve patients had been diagnosed with <25 mm ISVD and 4 of them had another secundum atrial septal defect (ASD). All patients were produced interventional therapy successfully. PDA occluder was implanted to closed ISVD, and ASD was closed using ASD occluder simultaneously. The average diameter of ISVD measured by TTE was (12.67±3.80), and the average diameter of sagittal axes and longitudinal axes measured by the 3D-printed model was (17.08±3.20) and (18.42±4.62) mm, respectively. The average size of PDA (diameter of pulmonary artery side) was (28.17±3.35) mm. Compared with the preoperative, the X-ray cardiothoracic ratio (0.51±0.04 vs. 0.47±0.06, P=0.007) and the right ventricle anterior-posterior diameter (31.17±5.65 vs. 24.58±3.75 mm, P<0.001) of postoperative was significantly decreased. During the average (47.75±27.52) months follow-up, it has achieved satisfying results, and there were no severe adverse events such as device transposition, death, and pericardial tamponade occurred.Conclusions:Assisting by 3D heart model, transcatheter closure of ISVD with PDA occluder had an excellent outcome. This method provides a new considerable treatment strategy for ISVD.
Journal of thoracic disease 2022
Background: Transcatheter closure of paravalvular leak (PVL) has evolved into an alternative to surgery in high-risk patients. In this study, we introduce a new access for transcatheter closure of PVL and seek to evaluate the feasibility and safety of this access. Methods: We retrospectively analyzed patients undergoing transbrachial access for transcatheter mitral or aortic PVL closure (August 2017-November 2019) at our hospital. All patients underwent puncture of the brachial artery under local anesthesia. Results: The study population included 11 patients, with an average age of 55.91 ± 14.82 years. Ten out of 11 patients were successfully implanted with devices via the brachial artery approach, and one patient was converted to the transseptal approach. The technical success rate of transbrachial access was 90.9%. Mean NYHA functional class improved from 3.1 ± 0.5 before the procedure to 1.9 ± 0.5 after PVL closure. Severe paravalvular regurgitation (PVR) in five patients and moderate PVR in six patients prior to the procedure were significantly reduced to mild in four patients and none in seven patients after the procedure. Complications included one case of pseudoaneurysm and one case of moderate hemolysis aggravation after closure. One patient had an unknown cause of sudden death within 24 h after the procedure. The half-year mortality rate during follow-up was 9.1% (1/11). Conclusions: Transbrachial access for transcatheter closure of PVL may be a feasible and safe treatment and should include well-selected patients. It has several potential advantages of simplifying the procedure process and reducing postprocedural bed rest time.
Frontiers in cardiovascular medicine 2021
Background: There have been marked advances in devices such as Amplatzer Duct Occluder II (ADO-II) or vascular plug through 5Fr delivery sheath for closure of patent ductus arteriosus (PDA) in the past five decades, making it possible for cardiologists to deliver occluders via different approaches. However, comparisons of these different approaches have not been reported. Therefore, the aim of this study was to summarize and compare the advantages of different approaches for PDA closure, and to guide clinical strategies. Methods: This retrospective study included all patients undergoing transcatheter closure of PDA from 2019 to 2020. Patients were matched by 1:1 propensity score matching (PSM). The retrograde femoral artery approach (FAA) and simple vein approach (SVA) groups were compared with the conventional arteriovenous approach (CAA). Results: The average age of the 476 patients was 21.05 ± 21.15 years. Their average weight was 38.23 ± 24.1 kg and average height was 130.14 ± 34.45 cm. The mean diameter of the PDA was 4.29 ± 2.25 mm. There were 127 men and 349 women, comprising 205 adults and 271 children. Among them, 197 patients underwent CAA, 223 underwent SVA, and 56 underwent retrograde FAA. The diameter in the FAA group was smaller than that in the other two groups, but was similar in adults and children. In the PSM comparison of CAA and SVA, 136 patients with CAA and 136 patients with SVA were recruited. Simple vein approach was associated with markedly reduced length of hospital stay, length of operation, and contrast medium usage as compared with CAA (all P < 0.05). In the PSM comparison of FAA and CAA, 30 patients with CAA and 30 patients with FAA were recruited. The operation duration was longer in the CAA than in the FAA group. There were no significant differences in postoperative complications among groups. Conclusion: Patent ductus arteriosus closure by using the SVA and FAA is safe and effective, and has certain advantages in some respects as compared with CAA.
Frontiers in cardiovascular medicine 2021
AIMS:The aim of this study was to evaluate the safety and efficacy of percutaneous closure in patients with a ruptured sinus of Valsalva aneurysm (RSVA).METHODS AND RESULTS:A total of 29 patients with RSVA were retrospectively enrolled in our study. All patients were successfully treated by percutaneous closure and had a complete closure at discharge; however, two patients had a trivial procedure-related aortic regurgitation (AR) after the procedure. On a mean follow-up of 29.7±23.8 months (range 1-83 months), the two procedure-related AR disappeared three months and two years after the procedure, respectively. Trivial residual shunt was found in one patient, sinus of Valsalva aneurysm ruptured again in one patient and trivial to moderate AR was found in two patients during the follow-up.CONCLUSIONS:In appropriately selected patients with RSVA, percutaneous closure is an attractive alternative to surgery with high technical success and good short-term and midterm outcomes; however, long-term follow-up is mandatory.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology 2018
BACKGROUND:Limited data have reported the outcomes of percutaneous closure of patent ductus arteriosus (PDA) in patients with unilateral absence of pulmonary artery (UAPA). This study aimed to evaluate the symptomatology, diagnosis and therapy, especially the transcatheter closure of PDA in patients with PDA associated with UAPA.MATERIALS AND METHODS:Patients diagnosed with PDA and UAPA were retrospectively enrolled from August 2010 through January 2016. Clinical data, treatment and follow-up information were evaluated.RESULTS:Thirteen patients (6 males and 7 females) were diagnosed with PDA associated with UAPA. Percutaneous closure was successfully conducted in 6 patients successfully. The median age was 7 years (7 months to 37 years). The mean diameter of the PDA and occluders were 4.7 ± 1.8mm (2-7mm) and 11.3 ± 3.9mm (6-14mm), respectively. The mean pulmonary artery pressure was 41.5 ± 13.5mmHg (25-62mmHg). The diameter of PDA has no relationship with the degree of pulmonary artery pressure (r = 0.239, P = 0.648). In 4 patients, systolic pulmonary arterial pressure decreased significantly after closure with 69.0 ± 10.7 versus 48.0 ± 11.3mmHg (P = 0.146), and also the mean pulmonary arterial pressure was 54.5 ± 5.7 mm Hg versus 30.5 ± 3.9mmHg (P = 0.04). In all, 1 patient had a trace residual shunt, which disappeared within 24 hours.CONCLUSIONS:In appropriate patients with PDA associated with UAPA, transcatheter closure of PDA has the potential to improve the pulmonary artery hypertension. Further follow-up is required to monitor the long-term outcomes.
The American journal of the medical sciences 2017
BACKGROUND:Transcatheter closure has been a recognised treatment strategy for multiple atrial septal defects (mASDs). This study aimed to examine the feasibility, effectiveness, and safety of transcatheter closure of mASDs using dual Amplatzer septal occluder (ASO) devices.METHODS:We retrospectively reviewed 34 patients who underwent transcatheter closure of mASDs using dual ASO devices from April 2005 to December 2014.RESULTS:Eight men and 26 women who successfully underwent transcatheter closure of mASDs were included. Ten (29.4%) patients had 3 defects or more. The mean diameters of the larger and smaller defects were 14.0±3.9 mm (8-20 mm) and 9.1±2.6 mm (4-15 mm), respectively. The mean diameters of the larger and smaller devices were 22.2±4.8 mm (13-30 mm) and 17.3±4.1 mm (10-26 mm), respectively. Devices were deployed by the "sandwiches" technique or an interleaved pattern. Immediately after the procedure, 23 (67.6%) patients had complete closure and 11 patients had a residual shunt (6 trivial, 3 small, 1 moderate, 1 large). During the 6 months of follow-up, 30 (88.2%) patients had complete closure of the shunt and 4 patients had a residual shunt (1 large, 3 small). Complications included 2 cases of pericardial effusion, which disappeared at 3 months.CONCLUSIONS:Simultaneous device implantation in transcatheter closure of mASDs is feasible and effective. The incidence rate of residual shunts is slightly high in the short term, but tends to decrease during mid-term follow-up.
The American journal of the medical sciences 2016
AIMS:Pericardial effusion (PE) without obvious periprocedural complications (e.g., cardiac perforation, device erosion) may occur after transcatheter closure of secundum atrial septal defects (ASD). The aim of the study was to investigate the incidence and predictors of PE unrelated to procedural complications.METHODS AND RESULTS:We included all patients who had undergone successful percutaneous ASD closure from June 2009 to April 2014 (n=2,652) with no pre-existing PE or cardiac perforation or erosion. Transthoracic echocardiography (TTE) was performed during the procedure and one, three, and six months postoperatively. After device implantation, fifty patients (1.9%) developed new-onset PE (37 immediately, 13 during follow-up). These patients were asymptomatic, stable haemodynamically, and had no new arrhythmias. PE appeared mild (5.1±1.9 mm) and homogeneously echolucent by TTE. PE diminished spontaneously. Compared with 2,602 patients without PE, factors independently predicting asymptomatic PE were the device touching the atrial free wall, device size, patient age, and total defect size. Areas under the receiver operating characteristic curves were 0.78 (p<0.001), 0.66 (p<0.001) and 0.77 (p<0.001) for device size, patient age, and total defect size, respectively.CONCLUSIONS:This is the first systematic report of a new type of PE. Our data provide new insights into new-onset PE after percutaneous ASD closure.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology 2016
BACKGROUND:Transthoracic Doppler-echocardiography (TTE) can estimate mean pulmonary arterial pressure (MPAP) and pulmonary capillary wedge pressure (PCWP) reliably, and cardiac magnetic resonance (CMR) is the best modality for non-invasive measurement of cardiac output (CO). We speculated that the combined use of TTE and CMR could provide a feasible method for non-invasive measurement of pulmonary vascular resistance (PVR) in pulmonary arterial hypertension (PAH).METHODS AND RESULTS:Right heart catheterization (RHC) was undertaken in 77 patients (17M/60F) with PAH, and simultaneous TTE was carried out to evaluate MPAP, PCWP and CO. Within 2 days, CO was measured again with CMR in similar physiological status. Then, PVR was calculated with the integrated non-invasive method: TTE-derived (MPAP-PCWP)/CMR-derived CO and the isolated TTE method: TTE-derived (MPAP-PCWP)/TTE-derived CO, respectively. The PVR calculated with integrated non-invasive method correlated well with RHC-calculated PVR (r = 0.931, 95% confidence interval 0.893 to 0.956). Between the integrated non-invasive PVR and RHC-calculated PVR, the Bland-Altman analysis showed the satisfactory limits of agreement (mean value: - 0.89 ± 2.59). In comparison, the limits of agreement were less satisfactory between TTE-calculated PVR and RHC-calculated PVR (mean value: - 1.80 ± 3.33). Furthermore, there were excellent intra- and inter-observer correlations for the measurements of TTE and CMR (P < 0.001 for all).CONCLUSIONS:The combined use of TTE and CMR provides a clinically reliable method to determine PVR non-invasively. In comparison with RHC, the integrated method shows good accuracy and repeatability, which suggests the potential for the evaluation and serial follow-up in patients with PAH.TRANSLATIONAL PERSPECTIVE:In PAH, the non-invasive measurement of PVR is very important in clinical practice. Up to now, however, the widely accepted non-invasive method is still unavailable. Since TTE can estimate (MPAP-PCWP) reliably and CMR is the best image modality for the measurement of CO, the combined use of two modalities has the potential to determine PVR non-invasively. In this research, the integrated non-invasive method showed good diagnostic accuracy and repeatability compared with RHC. Therefore, it might be a feasible method for non-invasive measurement of PVR in patients with PAH.
International journal of cardiology. Heart & vasculature 2015