张也
中国医学科学院阜外医院 功能检测科
Objective: To explore and study the clinical usefulness of continuous dynamic recording of left cardiac function changes forevaluation the improvement in patients with chronic disease after 3 months of intensive control of individualized precision exercise overall manage program. Methods: From 2018 to 2021, 21 patients with chronic cardiovascular and cerebrovascular metabolic diseases mainly controlled by our team were selected to complete the cardiopulmonary exercise test (CPET) and Non-invasive synchronous cardiac function detector (N-ISCFD), electrocardiogram, radial pulse wave, jugular pulse wave and cardiogram data were continuously recorded for 50s.According to the titration results under CPET and continuous functional parameters monitoring, a holistic plan with individualized moderate exercise intensity as the core was developed for 3 months of intensive management, and then N-ISCFD data collection was repeatedafter signing the informed consent. All N-ISCFD data were analyzed in the 50s according to the optimal report mode of Fuwai Hospital and 52 cardiac functional indexes were calculated. The data before and after the enhanced control were compared and the paired T-test was used to statistically analyze the changes of groups. Results: Twenty-one patients with chronic diseases (16 male and 5 female) were (54.05±12.77,29~75) years, BMI (25.53±4.04,16.62~31.7) kg/m2.Comparison with baseline,the whole group analysis: ①The body weight, BMI, systolic blood pressure and diastolic blood pressure of patients were significantly decreased(P<0.01).②CPET Peak VO2 was (64.93±24.22, 26.96~103.48) %Pred before enhanced control, and (85.22±30.31, 43.95~140.48) %Pred after enhanced control, and increased (35.09±27.87, 0.12~129.35) % after enhanced control compared with before enhanced control. The AT, Peak VO2/HR, Peak Work Rate, OUEP, FVC, FEV1, FEV3/FVC% and MVV were significantly increased (P<0.01) and the Lowest VE/VCO2 and VE/VCO2 Slope were significantly decreased(P<0.01).③Core indicators of left heart function:Ejection fraction was significantly increased from (0.60±0.12,0.40~0.88) to(0.66±0.09, 0.53~0.87)(P< 0.01), by (12.39±14.90,-12.32~41.11)%. The total peripheral resistance was significantly decreased from (1579.52±425.45,779.46~2409.61) G/(cm4·s),to(1340.44±261.49,756.05~1827.01) G/(cm4·s)(P<0.01), by (12.00±17.27,37.79~28.61) %.The left stroke index, cardiac total power, ejective pressure and left ventricular end diastolic volumewere significantly improved (P<0.05).The change analysis of each indicator for each patient is shown in the individualized analysis section of this study. Conclusion: Use CPET and continuous functional monitoring we can safely and effectively develop the overall program of individualized exercise in patients with chronic diseases. Long-term intensive management and control can safely and effectively significantly improve the cardiovascular function of patients. Continuous dynamic recording of changes in left and right cardiac functional parameters can be a simple way to supplement CPET to evaluate cardiovascular function.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2022
Objective: The cardiopulmonary function of patients with chronic heart failure (CHF) was severely limited, but the holistic integrative exercise pathophysiology is still unclear. Methods: After signed the consent form, Eighty three patients with severe CHF from October 2016 to October 2017 in Fuwai Hospital were performed Ramp incremental loading program CardioPulmonary Exercise Testing (CPET), and 12 normal subjects served as control. CPET were performed according to standard of Harbor-UCLA MC and the circulatory, respiratory and metabolic parameters during CPET were measured and analyzed. Results: Peak oxygen uptake (Peak VO2) in CHF (14.33±2.69) ml/(min·kg), (44.25±14.74)%pred was significantly lower than control ((29.42±5.46) ml/(min·kg), (83.88±6.28)%pred). Other core parameters of CPET such as anaerobic threshold (AT), peak oxygen pulse, oxygen uptake efficiency platform (OUEP), the lowest of carbon dioxide output ventilation ratio (Lowest VE/VCO2), and carbon dioxide output ventilation slope (VE/VCO2 Slope) in CHF were significantly different with the control group(P<0.01). The core parameters of lung function, such as forced expiratory volume in the first second (FEV1), forced vital capacity (FVC), FEV1/FVC, and carbon monoxide diffusion (DLCO) were significantly decreased (P<0.01). Systolic blood pressure during all stages of CPET in CHF was significantly lower than control group (P<0.05); Heart rate at AT, peak and recovery stages were significantly lower than control (P<0.01). Minute ventilation, tidal volume and respiratory frequency at rest, warm-up were significantly higher than control (P<0.05). Tidal volume at recovery was significantly higher than control (P<0.05). VO2 at AT, peak and recovery stages in CHF were significantly higher than control (P<0.01). Oxygen pulse at AT and peak were significantly higher than control (P<0.01). Pulse oxygen saturation during all stages of CPET in CHF were significantly lower than control (P<0.01). Conclusion: The decreased holistic functional capacity of cardiogenic CHF dominantly due to circulatory limitation, and secondly due to respiratory and metabolic limitation.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: To verify that the cardiopulmonary exercise testing (CPET) performed by clinical subjects is the maximum extreme exercise, we designed The Max test(Max)during clinical CPET. We used Max to verify the accuracy of the quantitative CPET evaluation result, and whether it is feasible and safe to use the specific value of a certain index as the standard for stopping CPET. Methods: Two hundred and sixteen cases from Fuwai Hospital were selected during June 2017 to January 2019,including 41 healthy person(control group) and 175with cardiovascular diseases(patient group),The patients had a CPET peak RER ≤ 1.10, or the peak heart rate and peak blood pressure were basically non-responsive.The Max was first attempted in 60 subjects,and this study is further expanded . When the CPET ended, they had a 5-minute break, then the Max, during which, they cycled with a velocity of ≥ 60 r/min, at a constant intensity equivalent to to 130% of peak work,until exhausted.The difference and percentage difference between the peak heart rate and the peak oxygen uptake were calculated. ①If the percentage difference of heart rate and oxygen uptake are all less than -10%,then the Max is defined as failure,otherwise it is succesful. 2 If the percentage difference is between -10%~10%, then the Max is successful, which proved that the CPET is precise.③If the difference is ≥10%, the Max is successful, which proves that the CPET is non-extreme exercise. Results: Patient group's Peak VO2(L/min,ml/(min·kg)),anaerobic threshold (L/min,ml/(min·kg),%pred),Peak VO2/HR(ml/beat, % pred),Peak RER,Peak SBP,Peak WR,peak heart rate,OUEP (ratio,%pred) were lower than those of the control group(P<0.05).The VE/ VCO2 Slope (ratio,%pred)and Lowest VE/ VCO2(ratio,%pred) were higher in the patient group than in the control group (P<0.05).No adverse events occurred during the CPET and Max in all cases. Among the 216 cases,Max was successful in 198 cases(91.7%).CPET was proved to be maximum extreme exercise for 182 cases,non-maximum extreme exercise for 16 cases,and failed in 18 cases(8.3%).Conclusion: For CPET with a low peak RER and a maximum challenge,the Max can confirm the accuracy of the objective quantitative assessment of CPET. Max is safe and feasible,and that deserved further research and clinical application.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: The new theory of holistic integrative physiology and medicine, which describes the integrative regulation of respiratory, circulatory and metabolic systems in human body, generates the hypothesis of that breath is the origin of variability of circulatory parameters. We investigated the origin of heart rate variability by analyzing relationship between the breath and heart rate variability (HRV) during sleep. Methods: This retrospective study analyzed 8 normal subjects (NS) and 10 patients of chronic diseases without sleep apnea (CDs-no-SA). After signed the informed consent form, they performed cardiopulmonary exercise testing (CPET) in Fuwai Hospital and monitored polysomnography (PSG) and electrocardiogram (ECG) during sleep since 2014. We dominantly analyzed the correlation between the respiratory cycle during sleep and the heart rate variability cycle of the ECG R-R interval. The HRV cycle included the HR increase from the lowest to the highest and decrease from the highest to the lowest point. The number of HRV (HRV-n), average HRV time and other parameters were calculated. The breath cycle included complete inhalation and subsequent exhalation. The number of breath (B-n), average breath time and other breath parameters were analyzed and calculated. We analyzed each person's relationship between breath and HRV; and the similarities and differences between the NS and CDs-no-SA groups. Independent sample t test was used for statistical analysis, with P<0.05. Results: CPET core parameter such as Peak VO2 (83.8±8.9)% in NS were significantly higher than that (70.1±14.9)% in patients of chronic diseases without sleep apnea (P<0.05), but there was no difference between their AHI (1.7±1.3) in NS and AHI (2.9±1.2) in CDs-no-SA (P>0.05). The B-n and the HRV-n (6581.63±1411.90 vs 6638.38±1459.46), the average B time and the average HRV time (4.19±0.57)s vs (4.16±0.62)s in NS were similar without significant difference (P>0.05). The comparison of the numbers in CDs-no-SA were the number (7354.50±1443.50 vs 7291.20±1399.31) and the average times ((4.20±0.69)s vs (4.23±0.68)s) of B and HRV were similar without significant difference (P>0.05). The ratios of B-n/HRV-n in NS and CDs-no-SA were (0.993±0.027 vs 1.008±0.024) and both were close to 1 and similar without significant difference (P>0.05). The average magnitude of HRV in NS ((5.74±3.21) bpm) was significantly higher than that in CDs-no-SA ((2.88±1.44) bpm) (P<0.05). Conclusion: Regardless of the functional status of NS and CDs-no-SA, there is a similar consistency between B and HRV. The origin of initiating factors of HRV is the respiration.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: Under the guidance of the new theory of holistic integrated physiology and medicine, the effect of individualized accurate exercise program on the overall functional state was studied according to cardiopulmonary exercise testing (CPET). Methods: Li xx, female, 31 years old, has a fast heart rate since childhood (90~100 bpm), usually feel cold, especially in autumn and winter, and general health good. CPET was performed after signing the informed consent form at Fuwai Hospital in September 2019. Peak oxygen uptake, anaerobic threshold (AT), and peak cardiac output were (69~72)% pred, respectively, and the oxygen uptake ventilation efficiency and carbon dioxide exhaust ventilation efficiency were basically normal (96~100)% pred. The resting heart rate was fast, the blood pressure was low, the blood pressure response was weak during exercise, and the heart rate was mainly increased. The holistic integrated physiology medical theory pointed out that she was in weak health and heart weakness was the main manifestation. CPET was used to guide individualized precise exercise intensity titration, combine continuous beat-by-beat blood pressure, ECG, pulse and blood glucose dynamic monitoring to formulate an holisticplan of individualized quantitative exercise .Reexamine CPET after 8 weeks' strengthening management. Results: After 8 weeks of intensive holistic management, the limbs were warm and the cold symptoms disappeared. Re-examination of CPET peak oxygen uptake, AT and peak cardiac output were (90~98)% pred, which increased by (30~36)% respectively, and the holistic weak functional status was significantly improved; basically normal oxygen uptake ventilation efficiency and carbon dioxide exhaust ventilation efficiency also increased by (10~37)% respectively; resting heart rate and blood pressure basically returned to normal, and blood pressure and heart rate response during exercise were normal. Continuous ambulatory blood glucose monitoring indicated that the average blood glucose level decreased slightly and became more stable. Repeated measurement results of continuous ECG and beat-to-beat blood pressure also indicated a decrease in heart rate and an increase in blood pressure during rest, exercise and during sleep, and radial pulse wave. The amplitude of the dicrotic wave increases and becomes more pronounced. Conclusion: The new theoretical system to guide CPET to formulate an holistic plan for individualized precision exercise can safely and effectively enhance myocardial contractility, increase stroke volume, increase blood pressure, lower heart rate, stabilize and slightly lower blood glucose, and improve holistic functional status.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: Based on the hypothesis that respiration causes variability of circulatory indicators proposed by the holistic integrated physiology and medicine theory, the correlation between respiration and heart rate variability during sleep in chronically ill patients with abnormal sleep breathing is analyzed. Methods: Eleven chronically ill patients with abnormal sleep breathing and apnea-hypopnea index (AHI) ≥15 times/hr are recruited. After signing the informed consent, they completed the standardized symptomatic restrictive extreme exercise cardiopulmonary exercise testing (CPET) and sleep breathing monitoring Calculate and analyze the rules of respiratory nasal airflow and ECG RR interval heart rate variability during the oscillatory breathing (OB) phase and the normal steady breathing phase of the patient during sleep, and use the independent sample t test to compare with normal people and no sleep breathing abnormalities in the same period in this laboratory. Of patients with chronic diseases are more similar and different. Results: The peak oxygen uptake and anaerobic threshold (AT) of CPET in chronic patients with abnormal sleep apnea were (70.8±13.6)% Pred and (71.2±6.1)% Pred; 5 cases of CPET had exercise induced oscillatory breathing (EIOB), 6 An example is unstable breathing, which indicates that the overall functional status is lower than normal. In this group of patients with chronic diseases, AHI (28.8±10.0) beats/h, the ratio of the total time of abnormal sleep breathing to the total time of sleep (0.38±0.25); the length of the OB cycle (51.1±14.4)s. The ratio (Bn/HRV-B-n) of the number of breathing cycles in the normal and steady breathing period to the number of heart rate variability cycles in this group of patients with chronic diseases is 1.00±0.04, and the CV (SD of HRV-B-M/x) is (0.33 ±0.11), blood oxygen saturation (SpO2) did not decrease significantly, the average amplitude of heart rate variability (HRV-B-M) of each respiratory cycle rhythm was (2.64±1.59) bpm, although it was lower than normal people (P<0.05) , But it was similar to chronic patients without sleep apnea (P>0.05). In this group of patients with chronic diseases, the ratio of the number of respiratory cycles to the number of heart rate variability cycles (OB-Bn/OB-HRV-B-n) during OB is (1.22±0.18), and the average amplitude of heart rate variability for each respiratory cycle rhythm in OB (OB -HRV-B-M) is (3.56±1.57)bpm and its variability (OB-CV = SD of OB-HRV-B-M/x) is (0.59±0.28), the average amplitude of heart rate variability in each OB cycle rhythm (OB-HRV-OB-M) is (13.75±4.25)bpm, SpO2 decreases significantly during hypoventilation during OB, and the average decrease in SpO2 during OB (OB-SpO2-OB-M) is (4.79±1.39)%. The OB-Bn/OB-HRV-B-n ratio, OB-HRV-OB-M and OB-SpO2-OB-M in the OB period are all significantly higher than the corresponding indicators in the normal stable breathing period Large (P<0.01). Although OB-HRV-B-M has no statistically significant difference compared with HRV-B-M in normal stable breathing period (P>0.05), its variability OB-CV is significantly increased (P<0.01). Conclusion: The heart rate variability of chronic patients with abnormal sleep breathing in the OB phase is greater than that of the normal stable breathing period. When the breathing pattern changes, the heart rate variability also changes significantly. The number of breathing cycles in the stable breathing period is equal to the number of heart rate variability cycles.The ratio is the same as that of normal people and chronically ill patients without sleep apnea, confirming that heart rate variability is respiratory origin; and the reduction of heart rate variability relative to the respiratory cycle during OB is directly caused by hypopnea or apnea at this time, and heart rate variability is also breathing source.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: On the basis of preliminarily verifying the use of ultra-fast reaction polymer matrix optical fiber oxygen sensor and its measuring system to record the continuous and dynamic changes of carotid artery oxygen partial pressure (PaO2), in order to analyze and discuss the influence of lung ventilation on the continuous and dynamic changes of PaO2, we designed a whole animal experimental study in vivo. Methods: Four hybrid goats were selected, and the skin was cut and exposed directly under general anesthesia and tracheal intubation. The oxygen sensor, connected with the measuring system, was inserted directly into the left carotid artery to continuously record the dynamic changes of PaO2. With normal minute ventilation,mechanical ventilation is implemented through three tidal volumes: normal tidal volume (VT=15 ml/kg, Rf=20 bpm), half tidal volume (halved VT, doubled Rf) and double tidal volume (doubled VT, halved Rf). Each tidal volume was stable for 10~15 min respectively. We analyzed and calculated the average values of PaO2, the fluctuation magnitudes of PaO2 changes between breaths of last 180 s and the delay times of lung-carotid artery were. We analyzed the effects of different tidal volumes. Results: The heart rate and blood pressure of living goats were maintained stable during the mechanical ventilation experiment with normal ventilation volume Lung-carotid artery delay time is 1.4~1.8 s (about 3 heartbeats at this time). Under normal tidal volume of mechanical ventilation, the average value of PaO2 was (102.94±2.40, 99.38~106.16) mmHg, and the fluctuation range was (21.43±1.65, 19.21~23.59) mmHg, accounting for (20.80± 1.34, 18.65~22.22)% of the average value. Under the condition of halving tidal volume, the average value of PaO2 was maintained at (101.01±4.25, 94.09~105.66) mmHg, which was slightly decreased but not significant (P>0.05 compared with normal mechanical ventilation), but the fluctuation range of PaO2 was significantly reduced to (18.14±1.43, 16.46~20.05) mmHg, accounting for 17.5% of the average value. Under double tidal volume mechanical ventilation, although the average value of PaO2 increased slightly remained at (106.42±4.74, 101.19~114.08) mmHg (P>0.05 compared with normal mechanical ventilation and P<0.05 compared with half tidal volume mechanical ventilation), the fluctuation magnitude of PaO2 increased significantly to (26.58±1.88, 23.46~28.46)mmHg. Conclusion: Inspiration and expiration of normal lung ventilation are the initial factors for the increase and decrease of PaO2 in carotid artery. Under normal ventilation, halving tidal volume and doubling tidal volume significantly changed the fluctuation magnitude of PaO2, but the average value of PaO2 changed only slightly, while the lung-carotid delay time was similar.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: Observe the increased anatomical dead space of the mask, summarize the law of exercise induced oscillatory breathing (EIOB) in the results of CPET's new 9 figure, and analyze its incidence and age groups that are prone to oscillatory breathing. Methods: After signed the informed consent form by guardian, 501 children from pre-school to middle-school, aged 3~14 year, performed Harbor-UCLA standard protocol CPET with strict quality control in the CPET laboratory of Liaocheng Children's Hospital since 2014. CPET data was interpreted second by second from the breath by breath collection, averaged by 10s and then display by 9 plots. We analyzed the trends, pattern, incidence and age difference for EIOB and gas leakage. Results: The incidence of EIOB was the highest in the 3 to 6-year-old group, which was 42%. The 7 to 10-year-old group was 29.4% and the 11- to 14-year-old group was 29.9%. The three groups were tested by chi-square (x2=7.512), and the difference was statistically significant (P<0.05). 14 out of 508 children had air leakage during CPET, the incidence rate was 2.7%. Conclusion: The phenomenon of oscillatory breathing (OB) in children may be caused by the increased anatomical dead space of the mask, and it is not caused by disease. To improve the quality of CPET and to reduce clinical misdiagnosis, it is recommended to use a mouthpiece to decrease the dead space rather than the musk.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: In order to explore the mechanism of neonatal spontaneous breathing, the difference of oxygen and carbon dioxide between umbilical cord arteries and veins before the start of spontaneous breathing after birth has been analyzed among people. In this part, the related information is analyzed individually. Methods: After all fetal parents signed the informed consent before birth, and before the newborn was born and did not breathe, the umbilical cord was exposed as quickly as possible, and the heparinized arterial indwelling needle was inserted into the umbilical artery and umbilical vein in the direction of newborn and placenta, and then blood was taken continuously. Although dozens of mothers were selected,but only 3 cases were collected from Pua and Puv blood samplers at the same time for blood gas analysis and determination, and the differences and dynamic changes of umbilical vein and umbilical artery were calculated and analyzed. Results: In all 3 none spontaneous breathing newborns,PuvO2 was significantly higher than PuaO2 at the same time (P<0.01), with an average difference of (24.17±7.09) mmHg; while PuvCO2 was significantly lower than PuaCO2 (all P<0.01), with an average difference of (-7.67±3.70) mmHg.The difference of Puv-uaO2 was significantly higher than those of Puv-uaCO2 (P<0.05). Conclusion: PuaO2 decreases gradually with time (heartbeat frequency) before spontaneous breathing after the delivered fetus as a newborn, and it induces the first inhalation to start spontaneous breathing when it reaches the threshold of triggering breathing.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021
Objective: To observe the effect of healthy volunteers different work rate increasing rate cardiopulmonary exercise testing (CPET) on the sub-peak parameters . Methods: Twelve healthy volunteers were randomly assigned to a moderate (30 W/min), a relatively low (10 W/min) and relatively high (60 W/min) three different work rate increasing rate CPET on different working days in a week. The core indicators related to CPET sub-peak exercise of 12 volunteers were compared according to standard Methods: anaerobic threshold (AT), oxygen uptake per unit power (ΔVO2/ΔWR), oxygen uptake eficiency plateau,(OUEP), the lowest average of 90 s of carbon dioxide ventilation equivalent (Lowest VE/ VCO2), the slope of carbon dioxide ventilation equivalent (VE/ VCO2 Slope) and intercept and anaerobic threshold oxygen uptake ventilation efficiency value (VO2/ VE@AT) and the anaerobic threshold carbon dioxide ventilation equivalent value (VE/ VCO2@AT). Paired t test was performed on the difference of each parameter in the three groups of different work rate increasing rate. Results: Compared with the relatively low and relatively high work rate increasing rate group, the moderate work rate increasing rate group uptake eficiency plateau, (42.22±4.76 vs 39.54±3.30 vs 39.29±4.29) and the lowest average of 90 s of carbon dioxide ventilation equivalent (24.13±2.88 vs 25.60±2.08 vs 26.06±3.05) was significantly better, and the difference was statistically significant (P<0.05); Compared with the moderate work rate increasing rate group, the oxygen uptake per unit work rate of the relatively low and relatively high work rate increasing rate group increased and decreased significantly ((8.45±0.66 vs 10.04±0.58 vs 7.16±0.60) ml/(min·kg)), difference of which was statistically significant (P<0.05); the anaerobic threshold did not change significantly ((0.87±0.19 vs 0.87±0.19 vs 0.89±0.19) L/min), the difference was not statistically significant (P>0.05). Conclusion: Relatively low and relatively high power increase rate can significantly change the CPET sub-peak sports related indicators such as the effectiveness of oxygen uptake ventilation, the effectiveness of carbon dioxide exhaust ventilation, and the oxygen uptake per unit work rate. Compared with the moderate work rate increasing rate CPET, the lower and higher work rate increasing rate significantly reduces the effectiveness of oxygen uptake ventilation and the effectiveness of carbon dioxide exhaust ventilation in healthy individuals. The standardized operation of CPET requires the selection of a work rate increasing rate suitable for the subject, so that the CPET sub-peak related indicators can best reflect the true functional state of the subject.
Zhongguo ying yong sheng li xue za zhi = Zhongguo yingyong shenglixue zazhi = Chinese journal of applied physiology 2021