Multiple leadless pacemakers implanted in the right ventricle of swine.

AIMS:The miniaturized leadless pacemaker has recently emerged as a bradycardia therapy in humans, and many patients may need at least two pacemakers in their lifetime. Thus, the present study assessed the effect of two leadless pacemakers in the right ventricle (RV) on cardiac function in a swine model.METHODS AND RESULTS:Fourteen mini pigs were chronically studied. Each animal received two sequential leadless pacemakers in the RV with 1 month between two separate implantations. All animals were then followed for 6 months. Cardiac function was assessed with echocardiography at baseline, the second implantation, and the end of the 6-month follow-up. A necropsy at the end of the study was performed to measure the length of the fibrous tissue covering the devices and assess tricuspid valve integrity. Four animals died during the surgical procedure, and one animal died of infection during the follow-up period. In the remaining nine animals, there were no significant changes in left ventricular ejection fraction, aortic time integral, cardiac output, and left ventricular size from baseline to the end of the study. The mean length of fibrous tissue covering Micra devices was 14.3 ± 7.8 mm. No tricuspid valve injury was observed.CONCLUSION:Multiple leadless pacemakers implanted in the RV do not appear to impact cardiac function. Therefore, it appears safe to implant multiple leadless pacemakers in the same heart.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2016

The role of variability in night-time mean heart rate on the prediction of ventricular arrhythmias and all-cause mortality in implantable cardioverter defibrillator patients.

AIMS:This study was to use implantable cardioverter defibrillator (ICD) home monitoring (HM) feature to evaluate the role of mean night-time heart rate (MNHR) in the occurrence of ventricular arrhythmias (VAs) and mortality.METHODS AND RESULTS:This study retrospectively analysed clinical and ICD device data in 318 ICD patients. Data of the first 30-day MNHR (recorded 02:00-06:00 am) by HM were collected. The average and standard deviation of 30-day MNHR (AVHR and SDHR, respectively) were then determined in each patient. The primary endpoint was appropriate ICD treatment of VAs. The secondary endpoint was all-cause mortality. During a mean follow-up period of 32 ± 10 months, 179 of the 318 patients (56.3%) experienced VAs, 123 patients (38.7%) were treated by ICD shocks, and 37 patients (11.6%) died. The overall SDHR in this study cohort was 4.5 ± 3.0 bpm. Based on the receiver operating characteristic curve, the cut-off value of SDHR = 3.685 bpm was identified to predict VAs. In the Kaplan-Meier survival, SDHR ≥ 3.685 bpm was associated with increased VAs [hazard ratio (HR) = 1.885; 95% confidence interval (CI) = 1.362-2.609; P < 0.001], shock events (HR = 1.637; 95% CI = 1.11-2.414; P = 0.013), all-cause mortality (HR = 2.42; 95% CI = 1.266-4.627; P = 0.008), and the combined endpoints (HR = 1.872; 95% CI = 1.365-2.567; P < 0.001). In univariate and multivariate Cox models (adjusting for clinical factors), SDHR ≥ 3.685 bpm was still an independent predictor for all endpoints.CONCLUSION:In ICD population, SDHR ≥ 3.685 bpm was an independent predictor for VAs and all-cause mortality.

6.1
1区

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2015