李叶丹

中国医学科学院阜外医院 超声科

Echocardiography in the diagnosis of Shone's complex and analysis of the causes for missed diagnosis and misdiagnosis.

BACKGROUND:Shone's complex is a rare syndrome characterized by congenital left heart defects that can differ among the patients.AIM:To use echocardiography in the diagnosis of Shone's complex and analyze the causes of missed diagnosis and misdiagnosis.METHODS:This was a retrospective study of patients who underwent echocardiography and repair surgery from February 14, 2008, to November 22, 2019. The patients were followed once a year at the outpatient clinic after surgery.RESULTS:Sixty-six patients were included. The patients were 2.7 (0.8-5.6) years of age, and 54.5% were male. Ten (15.2%) had a history of heart surgery. The most common heart defect was the Annulo-Leaflet mitral ring (ALMR) (50/66, 75.8%), followed by coarctation of the aorta (CoA) (43/66, 65.2%). The patients had a variety of combinations of defects. Only two (3.0%) patients had all four defects. None of the patients had a family history of congenital heart disease. The preoperative echocardiographic findings were examined against the intraoperative findings. Echocardiography missed an ALMR in 31 patients (47.0%), a parachute mitral valve (PMV) in one patient (1.5%), subaortic stenosis in one patient (1.5%), and CoA in two patients (3.0%).CONCLUSION:Echocardiography is an effective method to diagnose the Shone's complex. Due to this disease's complexity and interindividual variability, Improving the understanding of the disease can reduce misdiagnosis and missed diagnosis.

1.1
4区
第一作者

World journal of clinical cases 2022

Ultrasound-Guided Percutaneous Balloon Aortic Valvuloplasty for Aortic Stenosis.

Percutaneous balloon aortic valvuloplasty (PBAV), which is used to treat symptomatic aortic stenosis, requires ionizing radiation and contrast agent for imaging guidance. The aim of the study is to evaluate the feasibility and effectiveness of ultrasound-guided PBAV in patients with aortic stenosis. This case series included 30 patients (14 males; mean age, 61.5 ± 4.5 years) with moderate/severe aortic stenosis treated with ultrasound-guided PBAV at the Ultrasound Department, Fuwai Hospital, Beijing, China, between January 2016 and July 2019. Cardiac function (New York Heart Association grade) was assessed before PBAV and 1 month after the procedure. Aortic peak jet velocity, aortic valve orifice area (AVA), mean transvalvular pressure gradient (MTPG), left ventricular end-diastolic diameter (LVDD), left ventricular ejection fraction (LVEF), and left ventricular end-systolic diameter (LVESD) were determined before and immediately after PBAV using Doppler echocardiography. Preprocedural cardiac function was grade I in 3 cases, grade II in 9 cases, grade III in 10 cases, and grade IV in 8 cases. Postprocedural cardiac function was grade I in 22 cases, grade II in 4 cases, and grade III in 4 cases, suggesting that cardiac function was improved by PBAV. Ultrasound-guided PBAV resulted in significant improvements (P < 0.05) in aortic peak jet velocity (3.68 ± 0.811 m/s vs. 4.79 ± 0.63 m/s), MTPG (33.77 ± 13.85 mmHg vs. 54.54 ± 13.81 mmHg), AVA (1.96 ± 0.25 cm2 vs. 0.98 ± 0.12 cm2), LVEDD (51.90 ± 3.21 mm vs. 65.60 ± 6.81 mm), LVEF (63.46 ± 11.29% vs. 56.31 ± 11.04%), and LVESD (35.50 2.62 mm vs. 45.20 ± 2.42 mm). Ultrasound-guided PBAV is feasible and achieves good short-term effects in patients with aortic stenosis.

2.1
3区
第一作者

Journal of interventional cardiology 2020