周政

中国医学科学院阜外医院 心内科22病房

Prognostic effect of stress hyperglycemia ratio on patients with severe aortic stenosis receiving transcatheter aortic valve replacement: a prospective cohort study.

BACKGROUND:Stress hyperglycemia ratio (SHR) has recently been recognized as a novel biomarker that accurately reflects acute hyperglycemia status and is associated with poor prognosis of heart failure. We evaluated the relationship between SHR and clinical outcomes in patients with severe aortic stenosis receiving transcatheter aortic valve replacement (TAVR).METHODS:There were 582 patients with severe native aortic stenosis who underwent TAVR consecutively enrolled in the study. The formula used to determine SHR was as follows: admission blood glucose (mmol/L)/(1.59×HbA1c[%]-2.59). The primary endpoint was defined as all-cause mortality, while secondary endpoints included a composite of cardiovascular mortality or readmission for heart failure, and major adverse cardiovascular events (MACE) including cardiovascular mortality, non-fatal myocardial infarction, and non-fatal stroke. Multivariable Cox regression and restricted cubic spline analysis were employed to assess the relationship between SHR and endpoints, with hazard ratios (HRs) and 95% confidence intervals (CIs).RESULTS:During a median follow-up of 3.9 years, a total of 130 cases (22.3%) of all-cause mortality were recorded. Results from the restricted cubic spline analysis indicated a linear association between SHR and all endpoints (p for non-linearity > 0.05), even after adjustment for other confounding factors. Per 0.1 unit increase in SHR was associated with a 12% (adjusted HR: 1.12, 95% CI: 1.04-1.21) higher incidence of the primary endpoint, a 12% (adjusted HR: 1.12, 95% CI: 1.02-1.22) higher incidence of cardiovascular mortality or readmission for heart failure, and a 12% (adjusted HR: 1.12, 95% CI: 1.01-1.23) higher incidence of MACE. Subgroup analysis revealed that SHR had a significant interaction with diabetes mellitus with regard to the risk of all-cause mortality (p for interaction: 0.042). Kaplan-Meier survival analysis showed that there were significant differences in the incidence of all endpoints between the two groups with 0.944 as the optimal binary cutoff point of SHR (all log-rank test: p < 0.05).CONCLUSIONS:Our study indicates linear relationships of SHR with the risk of all-cause mortality, cardiovascular mortality or readmission for heart failure, and MACE in patients with severe aortic stenosis receiving TAVR after a median follow-up of 3.9 years. Patients with an SHR exceeding 0.944 had a poorer prognosis compared to those with lower SHR values.

9.3
1区

Cardiovascular diabetology 2024

Development and validation of a score predicting mortality for older patients with mitral regurgitation.

OBJECTIVE:To develop and validate a user-friendly risk score for older mitral regurgitation (MR) patients, referred to as the Elder-MR score.METHODS:The China Senile Valvular Heart Disease (China-DVD) Cohort Study functioned as the development cohort, while the China Valvular Heart Disease (China-VHD) Study was employed for external validation. We included patients aged 60 years and above receiving medical treatment for moderate or severe MR (2274 patients in the development cohort and 1929 patients in the validation cohort). Candidate predictors were chosen using Cox's proportional hazards model and stepwise selection with Akaike's information criterion.RESULTS:Eight predictors were identified: age ≥ 75 years, body mass index < 20 kg/m2, NYHA class III/IV, secondary MR, anemia, estimated glomerular filtration rate < 60 mL/min per 1.73 m2, albumin < 35 g/L, and left ventricular ejection fraction < 60%. The model displayed satisfactory performance in predicting one-year mortality in both the development cohort (C-statistic = 0.73, 95% CI: 0.69-0.77, Brier score = 0.06) and the validation cohort (C-statistic = 0.73, 95% CI: 0.68-0.78, Brier score = 0.06). The Elder-MR score ranges from 0 to 15 points. At a one-year follow-up, each point increase in the Elder-MR score represents a 1.27-fold risk of death (HR = 1.27, 95% CI: 1.21-1.34, P < 0.001) in the development cohort and a 1.24-fold risk of death (HR = 1.24, 95% CI: 1.17-1.30, P < 0.001) in the validation cohort. Compared to EuroSCORE II, the Elder-MR score demonstrated superior predictive accuracy for one-year mortality in the validation cohort (C-statistic = 0.71 vs. 0.70, net reclassification improvement = 0.320, P < 0.01; integrated discrimination improvement = 0.029, P < 0.01).CONCLUSIONS:The Elder-MR score may serve as an effective risk stratification tool to assist clinical decision-making in older MR patients.

2.5
4区

Journal of geriatric cardiology : JGC 2023

Total Cholesterol Levels and Risk of Mortality or Heart Failure Rehospitalization in Patients With Valvular Heart Disease.

Low total cholesterol (TC) levels have been found to significantly increase mortality risk in patients experiencing heart failure. However, it is unclear whether the same relation applies specifically to patients with valvular heart disease (VHD). This study included patients with significant VHD from the China Valvular Heart Disease Study. Patients with atherosclerotic cardiovascular disease were excluded. The primary end point of this study was a combined indicator of either all-cause mortality or rehospitalization because of heart failure (HF). The association between TC and the primary outcome was evaluated using Cox proportional hazard models. The cut-off value of TC for predicting mortality or rehospitalization was determined by the maximally selected rank test. The study population comprised 6,235 patients with VHD. Over a 2-year follow-up period, there were 393 deaths and 265 HF rehospitalizations. The adjusted hazard models showed that for every 1 mmol/L decrease in TC, there was a 1.19-fold increased risk of death or HF rehospitalization (adjusted hazard ratio 1.19, 95% confidence interval 1.09 to 1.30, p <0.001). The optimal cut-off value of TC was 3.53 mmol/L; patients at or below this level had significantly higher mortality and HF rehospitalization rates. After adjustment for confounding factors, low TC levels (≤3.53 mmol/L) remained a significant risk factor for patients with aortic regurgitation, mitral regurgitation, and tricuspid regurgitation. Decreased TC levels are associated with an increased risk of death or HF rehospitalization among patients with VHD.

2.8
3区

The American journal of cardiology 2023

Development and validation of a deep learning-based fully automated algorithm for pre-TAVR CT assessment of the aortic valvular complex and detection of anatomical risk factors: a retrospective, multicentre study.

BACKGROUND:Pre-procedural computed tomography (CT) imaging assessment of the aortic valvular complex (AVC) is essential for the success of transcatheter aortic valve replacement (TAVR). However, pre-TAVR assessment is a time-intensive process, and the visual assessment of anatomical structures at the AVC shows interobserver variability. This study aimed to develop and validate a deep learning-based algorithm for pre-TAVR CT assessment and anatomical risk factor detection.METHODS:This retrospective, multicentre study used AVC CT scans to develop a deep learning-based, fully automated algorithm, which was then internally and externally validated. After loading CT scans into the algorithm, it automatically assessed the essential anatomical structure data required for TAVR planning. CT scans of 1252 TAVR candidates continuously enrolled from Fuwai Hospital were used to establish training and internal validation datasets, while CT scans of 100 patients with aortic valve disease across 19 Chinese hospitals served as an external validation dataset. The validation focused on segmentation performance, localisation and measurement accuracy of key anatomical structures, detection ability of specific anatomical risk factors, and improvement in assessment efficiency.FINDINGS:Relative to senior observers, our algorithm achieved significant consistent performance with remarkable accuracy, efficiency and ease in segmentation, localisation, and the assessment of the aortic annulus perimeter-derived diameter, and other basic planes, coronary ostia height, calcification volume, and aortic angle. The intraclass correlation coefficient values for the algorithm in the internal and external validation datasets were up to 0.998 (95% confidence interval 0.998-0.998), respectively. Furthermore, the algorithm demonstrated high alignment in detecting specific anatomical risk factors, with accuracy, sensitivity, and specificity up to 0.989 (95% CI 0.973-0.996), 0.979 (95% CI 0.936-0.995), 0.986 (95% CI 0.945-0.998), respectively.INTERPRETATION:Our algorithm efficiently performs pre-TAVR assessments by using AVC CT imaging with accuracy comparable to senior observers, potentially improving TAVR planning in clinical practice.FUNDING:National Key R&D Program of China (2020YFC2008100), CAMS Innovation Fund for Medical Sciences (2022-I2M-C&T-B-044).

11.1
1区

EBioMedicine 2023

Can Measuring the 'Dual Anchors of Aorta' Enhance the Success Rate of TAVR?-A Single-Center Experience.

INTRODUCTION:Chronic severe aortic regurgitation (AR) has a poor long-term prognosis, especially among old-age patients. Considering their advancing age, the surgical approach of aortic valve replacement may not always be the best alternative modality of treatment in such patients. Therefore, this study's primary goal was to provide an initial summary of the medium- and short-term clinical effectiveness of transcatheter aortic valve replacement (TAVR) guided by accurate multi-detector computed tomography (MDCT) measurements in patients with severe and chronic AR, especially in elderly patients.METHODS:The study enrolled retrospectively and prospectively patients diagnosed with severe AR who eventually underwent TAVR procedure from January 2019 to September 2022 at Fuwai cardiovascular Hospital, Beijing. Baseline information, MDCT measurements, anatomical classification, perioperative, and 1-year follow-up outcomes were collected and analyzed. Based on a novel anatomical categorization and dual anchoring theory, patients were divided into four categories according to the level of anchoring area. Type 1, 2, and 3 patients (with at least two anchoring regions) will receive TAVR with a transcatheter heart valve (THV), but Type 4 patients (with zero or one anchoring location) will be deemed unsuitable for TAVR and will instead receive medical care (retrospectively enrolled patients who already underwent TAVR are an exception).RESULTS:The mean age of the 37 patients with severe chronic AR was 73.1 ± 8.7 years, and 23 patients (62.2%) were male. The American Association of Thoracic Surgeons' score was 8.6 ± 2.1%. The MDCT anatomical classification included 17 cases of type 1 (45.9%), 3 cases of type 2 (8.1%), 13 cases of type 3 (35.1%), and 4 cases of Type 4 (10.8%). The VitaFlow valve (MicroPort, Shanghai, China) was implanted in 19 patients (51.3%), while the Venus A valve (Venus MedTech, Hangzhou, China) was implanted in 18 patients (48.6%). Immediate TAVR procedural and device success rates were 86.5% and 67.6%, respectively, while eight cases (21.6%) required THV-in-THV implantation, and nine cases (24.3%) required permanent pacemaker implantation. Univariate regression analysis revealed that the major factors affecting TAVR device failure were sinotubular junction diameter, THV type, and MDCT anatomical classification (p < 0.05). Compared with the baseline, the left ventricular ejection fraction gradually increased, while the left ventricular end-diastolic diameter remained small, and the N-terminal-pro hormone B-type natriuretic peptide level significantly decreased within one year.CONCLUSION:According to the results of our study, TAVR with a self-expanding THV is safe and feasible for patients with chronic severe AR, particularly for those who meet the criteria for the appropriate MDCT anatomical classification with intact dual aortic anchors, and it has a significant clinical effect for at least a year.

3.9
3区

Journal of clinical medicine 2023

[Single center experience of transcatheter aortic valve replacement with a simplified operative protocol].

Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.

Zhonghua xin xue guan bing za zhi 2022

[Preliminary evaluation on the efficacy of emergency transcatheter aortic valve replacement: a multicenter study].

Objectives: To explore the efficacy and safety of emergency transcatheter aortic valve replacement (TAVR). Methods: Data of patients who underwent emergency TAVR in eight centers, namely Fuwai Hospital, Wuhan Asia Heart Hospital, Xijing Hospital, Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Guangdong Provincial People's Hospital, Zhongshan Hospital Affiliated to Fudan University, the First Affiliated Hospital of Zhengzhou University, the Second Xiangya Hospital of Central South University, between May 2017 and December 2020 were retrospectively analyzed. The use of mechanical circulatory support system (MCS) and the results of laboratory tests (N-terminal B-type natriuretic peptide (NT-proBNP)) and echocardiography (mean aortic valve cross valve pressure difference and left ventricular ejection fraction) before and after operation were collected. The primary endpoint was all-cause death, and the secondary endpoints were stroke, major bleeding, major vascular complications, myocardial infarction, permanent pacemaker implantation, and acute renal injury. Device success was caculated, which refered to absence of procedural mortality and correct positioning of a single prosthetic heart valve into the proper anatomical location and intended performance of the prosthetic heart valve (mean aortic valve gradient<20 mmHg(1 mmHg=0.133 kPa) or peak velocity<3 m/s, with no moderate or severe prosthetic valve regurgitation). Kaplan-Meier survival curve was used to estimate the survival rate of patients during follow-up. Results: This study included 48 patients. The age was (72.5±8.1) years, and 34 patients were males (70.8%). Device success rate was 91.7% (44/48). The mean aortic valve transvalvular pressure was significantly decreased after operation ((12.3±6.4)mmHg vs. (60.2±23.8)mmHg, P<0.000 1). Left ventricular ejection fraction was significantly increased ((41.5±11.7)% vs. (31.0±11.3)%, P<0.000 1). NT-proBNP significantly decreased (3 492.0 (1 638.8, 7 165.5) ng/L vs. 12 418.5 (6 693.8, 35 000.0) ng/L, P<0.000 1). In-hospital all-cause mortality was 8.3% (4/48). During hospitalization, the rate of stroke was 2.1% (1/48), major bleeding was 6.3% (3/48), major vascular complications was 10.4% (5/48), myocardial infarction was 4.2% (2/48), permanent pacemaker implantation was 6.3% (3/48), and the rate of acute renal injury was 12.5% (6/48). MCS was used in 20 patients (41.7%). The median follow-up time was 196 days. During the follow-up, one patient died (due to systemic metastasis of pancreatic cancer), two cases suffered new myocardial infarction and one case received permanent pacemaker implantation. The survival rate of 30 days, 1 year and 2 years after the operation were 91.7% (44/48), 89.6% (43/48), 89.6% (43/48), respectively. Conclusion: Emergency TAVR may be a safe and effective treatment for patients with severe decompensated aortic valve stenosis.

第一作者

Zhonghua xin xue guan bing za zhi 2022

Anatomical morphology of the aortic valve in Chinese aortic stenosis patients and clinical results after downsize strategy of transcatheter aortic valve replacement.

BACKGROUND:The study aimed to describe the aortic valve morphology in Chinese patients underwent transcatheter aortic valve replacement (TAVR) for symptomatic severe aortic stenosis (AS), and the impact of sizing strategies and related procedural outcomes.METHODS:Patients with severe AS who underwent TAVR were consecutively enrolled from 2012 to 2019. The anatomy and morphology of the aortic root were assessed. "Downsize" strategy was preformed when patients had complex morphology. The clinical outcomes of patients who performed downsize strategy were compared with those received annular sizing strategy. The primary outcome was device success rate, and secondary outcomes included Valve Academic Research Consortium-3 clinical outcomes variables based on 1-year follow-up.RESULTS:A total of 293 patients were enrolled. Among them, 95 patients (32.4%) had bicuspid aortic valve. The calcium volume (Hounsfield Unit-850) of aortic root was 449.90 (243.15-782.15) mm 3 . Calcium is distributed mostly on the leaflet level. Downsize strategy was performed in 204 patients (69.6%). Compared with the patients who performed annular sizing strategy, those received downsize strategy achieved a similar device success rate (82.0% [73] vs . 83.3% [170], P  = 0.79). Aortic valve gradients (downsize strategy group vs . annular sizing group, 11.28 mmHg vs. 11.88 mmHg, P  = 0.64) and percentages of patients with moderate or severe paravalvular regurgitation 2.0% (4/204) vs . 4.5% (4/89), P  = 0.21) were similar in the two groups at 30 days after TAVR. These echocardiographic results were sustainable for one year.CONCLUSIONS:Chinese TAVR patients have more prevalent bicuspid morphology and large calcium volume of aortic root. Calcium is distributed mostly on the leaflet level. Compare with annular sizing strategy, downsize strategy provided a non-inferior device success rate and transcatheter heart valve hemodynamic performance in self-expanding TAVR procedure.

6.1
3区

Chinese medical journal 2022

[Initial clinical experience of left bundle branch pacing after transcatheter aortic valve implantation].

Objective: To investigate the efficacy and safety of left bundle branch pacing(LBBP) in patients after transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study. A total of 35 patients underwent TAVI and received pacemaker implantation from January 2018 to December 2020 in Beijing Fuwai Hospital were enrolled. Patients were divided into LBBP group (n=12) and right ventricular apex pacing (RVAP) group (n=23) according to the pacing position. The success rate of operation in LBBP group was calculated, and the occurrence of complications were observed, and the parameters of pacemaker were measured on the 3rd day and 1, 3 and 6 months after operation. The N-terminal pro-B-type natriuretic peptide (NT-proBNP), echocardiographic and ECG indexes were compared between the two groups on the 3rd day and 1, 3, and 6 months after pacemaker implantation. Result: A total of 35 patients were included, The age was (76.4±7.7) years, including 19 males (54.3%). The procedure time ((86.58±17.10)min vs. (68.74±9.18)min, P<0.001) and fluoroscopy duration ((20.08±4.44)min vs. (17.00±2.26)min, P<0.001) were significantly longer in LBBP group compared with RVAP group. The operation success rate of LBBP group was 11/12. There was no serious operation related complications such as pneumothorax, hemothorax, electrode dislocation, infection, and lower limb bleeding. The patients were followed up for 7.43 (5.21, 9.84) months. The programmed parameters of pacemaker were in the ideal range and stable during follow-up. At 3 and 6 months after operation, the left ventricular ejection fraction in LBBP group was higher than that in RVAP Group (at 3 months: (60.75±2.89)% vs. (57.35±3.33)%, P=0.004; at 6 months: (63.17±3.33)% vs. (56.17±3.97)%, P<0.001), NT-proBNP values was lower in LBBP group than that in RVAP Group (at 3 months: 822 (607, 1 150)ng/L vs. 1 052 (902, 1 536)ng/L, P=0.006; at 6 months: 440 (330,679)ng/L vs. 783 (588, 1 023)ng/L, P=0.001). At 1, 3 and 6 months after operation, the QRS duration was shorter in LBBP group than that in RVAP group (1 month: 99 (97, 107)ms vs. 126(124, 130)ms, P<0.001; 3 months: 98(96, 105)ms vs. 129(128, 133)ms, P<0.001; 6 months: 96(94, 104)ms vs. 130(128, 132)ms, P<0.001). Conclusions: For patients with permanent pacemaker indications after TAVI, LBBP is feasible, safe and reliable. It could improve the cardiac function in the short term, the long-term effect of LBBP needs to be further observed.

Zhonghua xin xue guan bing za zhi 2022

The effects of levosimendan in patients undergoing transcatheter aortic valve replacement- a retrospective analysis.

Background: Aortic stenosis (AS) increases left ventricular afterload, leading to cardiac damage and heart failure (HF). Transcatheter aortic valve replacement (TAVR) is an effective therapy for AS. No inotropic agents including levosimendan have been evaluated in patients undergoing TAVR. Methods: A total of 285 patients underwent TAVR between 2014 and 2019; 210 were included in the matched analysis and 105 received 0.1 μg/kg body weight/min levosimendan immediately after the prosthesis had been successfully implanted. Medical history, laboratory tests, and echocardiography results were analyzed. Endpoints including 2-year all-cause mortality, stroke, or HF-related hospitalization, and a combination of the above were analyzed by Cox proportional hazard models. Results: The levosimendan group had no difference in 2-year mortality compared with the control group (hazard ratio [HR]: 0.603, 95% confidence interval [CI]: 0.197-1.844; p = 0.375). However, levosimendan reduced stroke or HF-related hospitalization (HR: 0.346; 95% CI: 0.135-0.884; p = 0.027) and the combined endpoint (HR: 0.459, 95% CI: 0.215-0.980; p = 0.044). After adjusting for multiple variants, levosimendan still reduced stroke or HF-related hospitalization (HR: 0.346, 95% CI: 0.134-0.944; p = 0.038). Conclusion: Prophylactic levosimendan administration immediately after valve implantation in patients undergoing TAVR can reduce stroke or HF-related hospitalization but does not lower all-cause mortality.

5.6
2区

Frontiers in pharmacology 2022