朱达
云南省阜外心血管病医院 心内科
Prior to clinical application, reliability of percutaneous ventricular assist devices(pVAD) requires to be tested systematically. Currently, there's a lack of dedicated reliability testing equipment and methodologies for pVAD. Considering the structural and functional aspects of percutaneous ventricular assist devices, this study conducts research on pVAD reliability test engineering. Test setups, clinical conditions, failure modes, effects analysis, and evaluation models have been investigated. A highly feasible methodological approach for percutaneous ventricular assist device reliability assessment has been formed. This study offers valuable insights into standardizing their reliability evaluation in clinical settings.
Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation 2024
Objective: To evaluate the feasibility and safety of transcatheter tricuspid valve edge-to-edge repair guided by only transesophageal echocardiography (TEE). Methods: Patients with severe tricuspid regurgitation in Fuwai Yunnan Cardiovascular Hospital who met the inclusion criteria based on clinical and echocardiographic evaluationand underwent transcatheter tricuspid valve edge-to-edge repair between January 2022 and May 2023 were prospectively enrolled. The procedure was performed under general anesthesia with endotracheal intubation and solely guided by TEE. The patients underwent clinical evaluation, electrocardiogram and transthoracic echocardiography one month after the procedure. Results: A total of 22 patients (12 males and 10 females) were included, with an average age of (71.3±6.7) years. All 22 patients successfully underwent the transcatheter tricuspid valve edge-to-edge repair under TEE guidance, with an average of (1.5±0.6) clips implanted. Immediately after procedure, six patients had no or trace regurgitation, 15 patients had mild regurgitation, and one patient had moderate regurgitation. All 22 patients completed 30-day follow-up, with four patients having trace regurgitation, 17 patients having mild regurgitation, and one patient having moderate regurgitation. Echocardiographic measurements revealed that effective regurgitant orifice area, regurgitant volume, vena contracta width, and proximal isovelocity surface area radius significantly decreased after the procedure (all P<0.05). In addition, inferior vena cava width, right atrial volume, tricuspid annular diameter, and right ventricular end-diastolic diameter significantly improved (all P<0.05), but tricuspid annular plane systolic excursion and right ventricular fractional area change did not show significant differences compared with those before the procedure (both P>0.05). Conclusion: It has been preliminarily confirmed that transcatheter tricuspid valve edge-to-edge repair solely guided by TEE is feasible and safe, but requires more large-scale studies for further validation.
Zhonghua yi xue za zhi 2024
Although the use of bioabsorbable occluder is expected to reduce the risk of metal occluder-related complications, it has not been approved due to incomplete degradation and new complications. Novel fully bioabsorbable occluders were designed to overcome such limitations. The aim of this study was to investigate the efficacy and safety of a fully biodegradable occluder in patients with ventricular septal defects. 125 patients with perimembranous ventricular septal defect (VSD) larger than 3 mm were screened from April 2019 to January 2020 in seven centers. 108 patients were enrolled and randomized into the bioabsorbable occluder group (n = 54 patients) and nitinol occluder group (n = 54). A non-inferiority design was utilized and all patients underwent transcatheter device occlusion. Outcomes were analyzed with a 24-month follow-up. All patients were successfully implanted and completed the trial. No residual shunt >2 mm was observed during follow-up. Transthoracic echocardiography showed a hyperechoic area corresponding to the bioabsorbable occluder which decreased primarily during the first year after implantation and disappeared within 24 months. Postprocedural arrhythmia was the only occluder-related complication with an incidence of 5.56% and 14.81% for the bioabsorbable and nitinol groups, respectively (P = 0.112). The incidence of sustained conduction block was lower in the bioabsorbable occluder group (0/54 vs. 6/54, P = 0.036) at 24-month follow-up. In conclusion, the novel fully bioabsorbable occluder can be successfully and safely implanted under echocardiography guidance and reduce the incidence of sustained postprocedural arrythmia. The efficacy and safety of this fully biodegradable occluder are non-inferior to that of a traditional nitinol one.
Science bulletin 2023
European heart journal. Case reports 2023
BACKGROUND:This study used an atrial septal shunt to compare the treatment progress and prognosis for patients with heart failure (HF) who have different ejection fractions.METHODS:Twenty HF patients with pulmonary hypertension, who required atrial septal shunt therapy, were included in this study. The patients underwent surgery between December 2012 and December 2020. They were divided into two groups based on their ejection fraction: a group with reduced ejection fraction (HFrEF) and a group with preserved ejection fraction(HFpEF) + mid-range ejection fraction (HfmrEF). Echocardiography was utilized to evaluate parameters such as left ventricular dimension (LVD), left ventricular ejection fraction (LVEF), and left ventricular end-diastolic volume (LVEDV). Hemodynamic parameters were measured using cardiac catheterization. The patient's cardiac function was assessed using the six-minute walking test (6MWT), KCCQ score, NYHA classification, and the degree of functional mitral regurgitation (FMR). Followed-up visits were conducted at 1, 3, and 6 months, and any adverse effects were recorded.RESULTS:The LVEF values were consistently higher in the HFpEF+HFmrEF group than HFrEF group at all periods (P < 0.05). Differences in LVD were observed between the two groups before the surgery. Statistically, significant differences were found at the preoperative stage, 1 month, and 3 months (P < 0.05, respectively). However, the LVEDV showed a significant difference between the two groups only at 3 months (P = 0.049). Notably, there were notable variations in LAPm, LAPs, and the pressure gradient between the LA-RA gradient at baeline, after implantation, and during the 6 months follow-up (all P < 0.05).CONCLUSION:Following treatment, the HFpEF+HFmrEF group exhibited more significant improvements in echocardiographic and cardiac catheterization indices than the HFrEF group. However, there was no statistically significant difference between the two groups regarding the 6MWT and KCCQ scores. It is important to note that the findings of this study still require further investigation in a large sample size of patients.
Journal of cardiothoracic surgery 2023
INTRODUCTION:Calcific aortic valve disease (CAVD) is an active and cellular-driven fibrocalcific process characterised by differentiation of valve interstitial cells (VICs) towards an osteogenic-like phenotype. A recently identified lncRNA, lncTSI, has been reported to inhibit fibrogenesis through transforming growth factor (TGF)-β/Smad3 pathway. Here, the present study aimed to investigate the role of lncTSI in CAVD.METHODS:The effect of TGF-β1 on lncTSI of VICs was measured. TGF-β1, RUNX2 and collagen I expression between calcified aortic valve tissue and normal samples by immunohistochemistry and western blotting. Human VICs were cultured and treated with TGF-β1. SiRNA and pcDNA3.1-lncTSI plasmid transfection were used to silence and overexpress lncTSI in VICs for 48 h, Smads phosphorylation, RUNX2 and collagen I expression were then verified by western blotting. In ApoE-/- mice fed with 0.25 % high-cholesterol diet, AAV2-lncTSI were injected intravenously to observe their effect on the formation of aortic valve calcification.RESULTS:lncTSI was highly expressed in VICs treated with TGF-β1. lncTSI was transcriptionally regulated by Smad3 and reversely inhibited TGF-β1-induced Smad3 phosphorylation and downregulated profibrotic gene expression. Silencing lncTSI increased TGF-β1-induced Smad3 phosphorylation, and subsequently, upregulated RUNX2 and collagen I expressions in VICs. While overexpression of lncTSI reversed the production of RUNX2 and collagen I in VICs. In a mouse CAVD model of 24 week 0.25 % high-cholesterol diet feeding, overexpression of lncTSI significantly reduced calcium deposition, RUNX2, pSmad3, and collagen I expression in aortic valve leaflets, with less aortic valve stenosis.CONCLUSIONS:The novel findings of present study suggested that lncTSI alleviated aortic valve calcification through negative regulation of the TGF-β/Smad3 pathway. The results may help elucidate new diagnostic and therapeutic targets to prevent CAVD progression.
Metabolism: clinical and experimental 2023
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Zhonghua xin xue guan bing za zhi 2023
European heart journal. Cardiovascular Imaging 2023
Zhonghua xin xue guan bing za zhi 2023
Science bulletin 2022