Optimal treatment of tannic acid for the anti-calcification of bovine jugular veins and the underlying mechanism.

OBJECTIVES:To evaluate the effects of combined treatment with tannic acid and ferric ions on the biomechanical and anti-calcification properties of glutaraldehyde-fixed bovine jugular veins after xenografting.METHODS:Two-point bending test and uniaxial tensile test were used to evaluate the flexural and biomechanical properties; Subcutaneous implantation in rat and right ventricular outflow tract reconstruction of sheep were used to evaluate the anti-calcification effects; The performance of the graft in sheep models was evaluated every month after the surgery with echocardiography examination. Markers of macrophages, T lymphocytes, smooth muscle cell osteogenic differentiation and matrix metalloproteinases in sheep explants were detected by immunohistochemistry.RESULTS:The flexibility of the bovine jugular veins cotreated with ferric ions-tannic acid was improved while maintaining biomechanical properties and excellent anti-calcification effects. Echocardiography results showed that the grafts functioned well in the animals without stenosis or reflux of the valve. Immunohistochemical studies showed that the osteogenic differentiation marker (Runx2) was detected in calcified regions and colocalised with the SMC marker (α-SMA). Compared to the glutaraldehyde-treated samples, T-cell marker (CD3), matrix metalloproteinase-2 and 9 expressions were reduced in the ferric ions-tannic acid treated group.CONCLUSION:Ferric ions-tannic acid treatment can give the conduits better flexibility with excellent biomechanical properties and anti-calcification effects, making it a promising bovine jugular veins processing method.

1.7
4区

The International journal of artificial organs 2023

Effect of valve leaflet surface patterning on valve hydrodynamic performance.

OBJECTIVE:We aimed to elucidate the effects of the micro-structure of the pyrolytic carbon for artificial heart valves on its hydrodynamic performance.METHODS:Bileaflet mechanical valves of GKS 23 and 29 A were randomly selected. According to ISO5840, mean transvalvular pressure (MPG), regurgitation fraction (RF), and effective orifice area (EOA) of valve were assessed. Then, parallel-groove pattern was constructed by laser etching on leaflet surface, and the valves were subjected again to the same test.RESULTS:Compared with before patterning at 2, 3.5, 5, and 7 L/min, the MPG of the valves in two specifications were higher, the EOA was larger in 23 A, but smaller in 29 A, and the RF was contrary to EOA. At 5 L/min, the RF in both specifications was lower after etching at 45 bpm. At 70 bpm however, the RF in 23 A decreased, in 29 A increased.CONCLUSION:The parallel-groove pattern on leaflet surface affected the hemodynamic performance of the valve prostheses.

1.7
4区

The International journal of artificial organs 2023

Interventional Microbubble Enhanced Sonothrombolysis on Left Ventricular Assist Devices.

The left ventricular assist device (LVAD) is often used in the treatment of heart failure. However, 4% to 9% implanted LVAD will have thrombosis problem in one year, which is fatal to the patient's life. In this work, an interventional sonothrombolysis (IST) method is developed to realize the thrombolysis on LVAD. A pair of ultrasound transducer rings is installed on the shell of LVAD, and drug-loaded microbubbles are injected into the LVAD through the interventional method. The microbubbles are adhere on the thrombus with the coated thrombus-targeted drugs, and the thrombolytic drugs carried by the bubbles are brought into the thrombus by the cavitation of bubbles under the ultrasound. In a proof-of-concept experiment in a live sheep model, the thrombus on LVAD is dissolved in 30 min, without damages on LVADs and organs. This IST exhibits to be more efficient and safer compared with other thrombolysis methods on LVAD.

15.1
1区

Advanced science (Weinheim, Baden-Wurttemberg, Germany) 2022

Fabrication of a gradient hydrophobic surface with parallel ridges on pyrolytic carbon for artificial heart valves.

Effective surface modification to endow pyrolytic carbon (PYC) with long-term anti-thrombotic performance is highly demanded. In this work, a gradient hydrophobic surface on PYC was prepared by creating parallel ridges via the combination of laser etching technology and surface fluorosilanization. Scanning electron microscopy (SEM) observation confirms that the gradient hydrophobic surface is composed of a bare PYC region and four regions of parallel ridges with varying distances. The gradient hydrophobic surface is stable in air, phosphate buffer solution (PBS), and flowing PBS. Additionally, the gradient hydrophobic surface on PYC shows spontaneous droplet motion and much lower flow resistance than bare PYC. Compared to bare PYC, the gradient hydrophobic surface on PYC exhibits better blood compatibility and anti-adhesion performance. The results presented in this paper confirm that creating a gradient hydrophobic surface is an effective way of achieving long-lasting anti-thrombosis property.

5.8
2区

Colloids and surfaces. B, Biointerfaces 2021

Controllable synthesis of biomimetic nano/submicro-fibrous tubes for potential small-diameter vascular grafts.

Mimicking the morphological structure of native blood vessels is critical for the development of vascular grafts. Herein, small-diameter composite vascular grafts that integrate the nanofibrous bacterial cellulose (BC) and submicrofibrous cellulose acetate (CA) were fabricated via a combined electrospinning and step-by-step in situ biosynthesis. Scanning electron microscopy (SEM) observation shows the nano/submicro-fibrous morphology and well-interconnected porous structure of the BC/CA grafts. It is found that the BC/CA graft with a suitable BC content demonstrates lower potential of thrombus formation and enhanced endothelialization as compared to the BC and CA counterparts. Western blotting and RT-qPCR results suggest that the BC/CA-2 graft promotes endothelialization by improving expressions of genes vWF-1 and CD31 and protein CD31. The in vivo tests demonstrate much lower inflammatory response to the BC/CA graft. These results suggest that the BC/CA graft shows a great potential as an artificial graft for rapid formation of an endothelial cell monolayer.

7.0
3区

Journal of materials chemistry. B 2020

Laser-induced wettability gradient surface on NiTi alloy for improved hemocompatibility and flow resistance.

Blood contacting materials with anti-thrombotic surfaces are highly demanded in clinics. Despite considerable research on surface modifications, limited progress has been made on effective prevention of thrombosis for artificial implants such as mechanical valve prosthesis. Herein, wettability gradient surface, which can ideally exhibit good hemocompatibility and low flow resistance, was developed for potential reduction of thrombosis. The wettability gradient surface on a model substrate of nickel-titanium (NiTi) alloy was prepared via a simple and economic method that combined laser microfabrication and surface stearic acid self-assembly approach. Scanning electron microscopy (SEM) observation confirmed that the wettability gradient surface was composed of a smooth NiTi region and three porous regions with different pore sizes and distances. Contact angle measurement revealed that, together with a low surface energy layer, the structural topography gradient could create a wettability gradient surface on NiTi alloy which could drive droplet motion. When compared with bare NiTi, such wettability gradient surface exhibited better anti-adhesion property, which was beneficial to the hemocompatibility and thus showing a lower hemolysis rate. Additionally, the wettability gradient surface also showed much lower flow resistance than bare NiTi. These results demonstrate that the developed wettability gradient surface may be used to reduce thrombosis.

7.9
1区

Materials science & engineering. C, Materials for biological applications 2020

Long-term results of triple-layered small diameter vascular grafts in sheep carotid arteries.

There is an urgent clinical for small diameter vascular grafts (SDVGs) for use in the treatment of coronary artery disease. Moreover, biodegradable SDVGs are drawing increasing attention because they have the potential to restore vascular function with the degradation of vascular graft and tissue regeneration. In this study, we designed triple-layered SDVGs to mimic the native arterial structure, with each layer contributing its unique porosity to the porous structure. We evaluated triple-layered SDVGs in a sheep carotid arterial replacement model. After implantation for 12 months, two grafts were patent and indicated the feasibility of using grafts in large animals. Nevertheless, it was determined that both grafts formed aneurysms at the proximal end. The prevention of such aneurysms remains a challenge for future investigation.

2.2
4区

Medical engineering & physics 2020

Numerical investigation of the influence of a bearing/shaft structure in an axial blood pump on the potential for device thrombosis.

Adverse events caused by flow-induced thrombus formation around the bearing/shaft of an axial blood pump remain a serious problem for axial blood pumps. Moreover, excessive anticoagulation with thrombosis around the bearing potentially increases the risk of postoperative gastrointestinal bleeding. The purpose of this study is to analyze the influence of the bearing structure on the thrombosis potential of an axial blood pump. The bearing/shaft structure was embedded into an axial blood pump numerical model. The numerical simulation and analysis are focused on the low wall shear stresses, recirculation, and residence time close to the bearing region to evaluate the potential for thrombosis around the bearing. Then, the flow field near the blood pump bearing was tested via in vitro particle image velocimetry experiments to verify the numerical results. The simulation results showed that after embedding the bearing/shaft structure a recirculation zone appeared in the outlet guide vane bearing/shaft region, the residence time increased 11-fold in comparison to the pump without the bearing/shaft structure, the scalar shear stress in the shaft surface was less than 7.8 Pa, and the stress accumulation was less than 0.10 Pa s. The numerical results showed that platelets that flow through the bearing region are exposed to significantly lower wall shear stress and a longer residence time, leading to activated platelet adhesion. The reduced stress accumulation and increased time in the bearing region lead to increased platelet activation.

1.7
4区

The International journal of artificial organs 2019

Numerical Investigation of the Influence of Blade Radial Gap Flow on Axial Blood Pump Performance.

The gaps between the blades and the shroud (or hub) of an axial blood pump affect the hydraulics, efficiency, and hemolytic performance. These gaps are critical parameters when a blood pump is manufactured. To evaluate the influence of blade gaps on axial blood pump performance, the flow characteristics inside an axial blood pump with different radial blade gaps were numerically simulated and analyzed with special attention paid to the hydraulic characteristics, gap flow, hydraulic efficiency, and hemolysis index (HI). In vitro hydraulic testing and particle image velocimetry testing were conducted to verify the numerical results. The simulation results showed that the efficiency and pressure rise decreased when the gap increased. The efficiency of the axial blood pump at design point decreased from 37.1% to 27.1% and the pressure rise decreased from 127.4 to 71.2 mm Hg when the gap increased from 0.1 to 0.3 mm. Return and vortex flows were present in the outlet guide vane channels when the gap was larger than 0.2 mm. The HI of the blood pump with a 0.1 mm gap was 1.5-fold greater than that with a 0.3 mm gap. The results illustrated poor hydraulic characteristics when the gap was larger than 0.15 mm and rapidly deteriorated hemolysis when the gap was larger than 0.1 mm. The numerical and experimental results demonstrated that the pressure rise, pump efficiency, and scalar shear stress decreased when the gap increased. The HI did not strictly decrease with gap increases. The preliminary results encourage the improvement of axial blood pump designs.

4.2
3区

ASAIO journal (American Society for Artificial Internal Organs : 1992) 2019

[Design of an axial blood pump of diffuser with splitter blades and cantilevered main blades].

An implantable axial blood pump was designed according to the circulation assist requirement of severe heart failure patients of China. The design point was chosen at 3 L/min flow rate with 100 mm Hg pressure rise when the blood pump can provide flow rates of 2-7 L/min. The blood pump with good hemolytic and anti-thrombogenic property at widely operating range was designed by developing a structure that including the spindly rotor impeller structure and the diffuser with splitter blades and cantilevered main blades. Numerical simulation and particle image velocimetry (PIV) experiment were conducted to analyze the hydraulic, flow fields and hemolytic performance of the blood pump. The results showed that the blood pump could provide flow rates of 2-7 L/min with pressure rise of 60.0-151.3 mm Hg when the blood pump rotating from 7 000 to 11 000 r/min. After adding the splitter blades, the separation flow at the suction surface of the diffuser has been reduced efficiently. The cantilever structure changed the blade gap from shroud to hub that reduced the tangential velocity from 6.2 m/s to 4.3-1.1 m/s in blade gap. Moreover, the maximum scalar shear stress of the blood pump was 897.3 Pa, and the averaged scalar shear stress was 37.7 Pa. The hemolysis index of the blood pump was 0.168% calculated with Heuser's hemolysis model. The PIV and simulated results showed the overall agreement of flow field distribution in diffuser region. The blood damage caused by higher shear stress would be reduced by adopting the spindle rotor impeller and diffuser with splitter blades and cantilevered main blades. The blood could flow smoothly through the axial blood pump with satisfactory hydraulics performance and without separation flow.

Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi 2019