林静茹
中国医学科学院阜外医院
Background:Evaluation of the tricuspid valve (TV) is crucial for clinical decision making and post-treatment follow-up in pulmonary hypertension (PH) patients. However, little is known about 4-dimensional (4D) TV geometric remodeling in patients with PH. The aim of this study was to examine the 4D geometry of the TV in PH and its correlation with PH severity.Methods:A total of 74 PH patients with mean pulmonary arterial pressure >25 mmHg and 15 age- and gender-matched healthy individuals were consecutively included from September 2017 to December 2018 in National Center for Cardiovascular Diseases, Fuwai Hospital. All participants underwent 2-dimensional (2D) and 4D transthoracic echocardiography and PH patients underwent right heart catheterization (RHC) within 48 hours of echocardiography. TV geometry was analyzed using a dedicated 4D echocardiography from the right ventricular-focused apical view.Results:Compared with controls, PH patients had significantly larger 4D tricuspid annular (TA) and TV tenting sizes except in the 2-chamber diameter. In high-quality image cases, maximal tenting height (MTH), coaptation point height, tenting volume and 4-chamber diameter had good or moderate correlation with PH severity graded according to RHC mean pulmonary artery pressure (r=0.705, r=0.644, r=0.602, r=0.472, respectively; P<0.001 for all). In multivariable linear regression analysis, PH severity was independently associated with coaptation point height (F=18.070, P<0.001 with an R2=0.647) and MTH (F=25.576, P<0.001 with an R2=0.378). Among all 4D TV parameters, MTH had the highest area under the receiver operating characteristic (ROC) curve (AUC) in high-quality image cases [AUC =0.857, 95% confidence interval (CI): 0.743-0.972; P<0.001], comparable to echocardiographic systolic pulmonary arterial pressure (AUC =0.847, 95% CI: 0.733-0.961; P<0.001).Conclusions:In PH, TV geometric remodeling occurs mainly in TA septal-lateral dimension and TV tenting height. Worsening PH is an independent determinant of TV coaptation point height and MTH, not TA size. MTH shows a great diagnostic potential to detect severe PH.
Quantitative imaging in medicine and surgery 2024
BACKGROUND:Intracardiac echocardiography (ICE) provides accurate left atrial (LA) anatomical information in the procedure of atrial fibrillation (AF) ablation but lacks LA functional assessment. LA reservoir strain (LASr) is an excellent marker of LA reservoir function. This study aimed to assess the agreement between LASr derived from ICE and transthoracic echocardiography (TTE) in AF patients and analyze the reproducibility of LASr assessed by ICE combined with speckle tracking imaging.METHODS:This study prospectively enrolled 110 patients with a clinical diagnosis of AF who were ready for AF ablation, including 71 patients with paroxysmal AF and 39 with persistent AF. TTE and ICE examinations were performed on each individual before AF ablation. LASr measurements derived from ICE and TTE images were using dedicated LA-tracking software. Pearson correlation coefficients (r) and Bland-Altman plots were used to evaluate the agreement of LASr between the two modalities. Intraclass correlation coefficients (ICCs) were used to assess intra- and inter-observer reproducibility.RESULTS:The agreement between LASr obtained from ICE and TTE, especially between LASrLPV (LASr derived from LA left pulmonary vein view of ICE) and LASrTTE (LASr derived from TTE) were good in both paroxysmal and persistent AF patients [r = 0.890 (P < 0.001) for overall population; r = 0.815 (P < 0.001) and Bias ± LOA: -0.3 ± 9.9% for paroxysmal AF; r = 0.775 (P < 0.001) and Bias ± LOA: -2.6 ± 3.9% for persistent AF, respectively]. But the values of LASr derived from ICE were slightly lower than those of TTE, especially in patients with persistent AF. The ICCs for LASr derived from ICE were excellent (all ICCs > 0.90).CONCLUSIONS:In patients with AF, LASr derived from ICE demonstrated excellent reproducibility and showed good agreement with LASr obtained from TTE. Obtaining LASr from ICE images may be a supplementary method to evaluate LA reservoir function in AF patients and expands the potential of ICE in the field of cardiac function assessment.
Cardiovascular ultrasound 2023
BACKGROUND:Myocardial work (MW) derived from the left ventricular pressure-strain loop is a novel and noninvasive method for assessing left ventricular function that accounts for loading conditions. We aimed to explore whether global MW combined with treadmill exercise stress could detect significant coronary artery disease (CAD) in patients with angina pectoris.METHODS:Eighty-five patients with angina pectoris and no prior CAD history were included. All patients underwent treadmill exercise stress echocardiography and coronary angiography. Global MW was constructed from speckle-tracking echocardiography indexed to the brachial systolic blood pressure. The association between MW parameters and the presence of significant CAD was assessed with logistic regression. The discriminative power of MW parameters to detect CAD was assessed with receiver operative characteristic curve, net reclassification improvement, and integrated discrimination improvement analysis.RESULTS:Twenty-five patients had a positive exercise echocardiogram, while significant coronary artery stenosis (≥70% in one or more major epicardial vessels or ≥50% in the left main coronary artery) was observed in 41 patients. The global wasted work (GWW) and global work efficiency (GWE) were significantly higher or lower, respectively, in patients with significant CAD compared with those of nonsignificant CAD at the peak exercise and during recovery periods (P < .05 for all). Multivariate logistic regression analysis demonstrated that peak GWE and recovery GWW could predict significant CAD. Peak GWE had the highest area under the receiver operating characteristic curve (AUC) among all global MW parameters (AUC = 0.836). Furthermore, a model comprising peak GWE and recovery GWW performed better for the identification of significant CAD than peak GWE alone (AUC = 0.856).CONCLUSIONS:Peak GWE could detect significant CAD. The new model, incorporating peak GWE and recovery GWW, not only identified but also provided additional value for estimating the probability of significant CAD. Global MW parameters combined with exercise stress perform as an accurate noninvasive screening before the invasive diagnostic technique.
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography 2022
Background: Left bundle branch pacing (LBBP) is an alternative strategy for His bundle pacing (HBP). This study aimed to analyze the long-term performance of LBBP and the potential factors affecting long-term cardiac function. Methods: Patients with LBBP were continuously enrolled from January 2018 to August 2020. Pacing parameters, electrocardiogram (ECG), and echocardiography were collected. The anatomic position of LBBP leads was described by echocardiographic and fluoroscopic parameters. Results: A total of 91 patients with a median follow-up of 18 months were enrolled. Most patients maintained stable pacing parameters during follow-up. The intra-septal position of the 3830 lead also remained stable as the distance from the lead tip to the left surface of the ventricular septum was 0.4 (0, 1.4) mm. The overall level of left ventricular ejection fraction (LVEF) slightly increased. 59 patients had improved LVEF (∆LVEF > 0), while 28 patients had unchanged or reduced LVEF (∆LVEF ≤ 0). The declines of baseline LVEF, ∆ Paced QRSd, and corrected longitudinal distance (longit-dist) of lead-implanted site correlated with LVEF improvement, and these three factors had negative linear correlations with ∆LVEF. Patients with tricuspid valve regurgitation (TVR) deterioration had longer follow-up duration (20.5 vs. 15.0 months, p = 0.01) and shorter Lead-TVA-dist (18.6 vs. 21.6 mm, p = 0.04) than those without TVR deterioration. Conclusion: Patients with LBBP generally remained stable in pacing performance, anatomic lead positions, and cardiac function in long-term follow-up. Baseline LVEF, ∆ Paced QRSd, and corrected longit-dist might be associated with potential LVEF decrease, which required further confirmation.
Frontiers in physiology 2022
Background: Four-dimensional automatic right ventricular quantification technology (4D auto-RVQ) is a new method that can simultaneously measure right ventricular (RV) structure and strain. The role of 4D auto-RVQ in determining RV function and hemodynamics is not clear. The role of 4D auto-RVQ in determining RV function and hemodynamics is not clear. We assessed the 4D auto-RVQ to measure right heart structure, function, and hemodynamics in patients with pulmonary hypertension (PHTN) correlated with right heart catheterization (RHC). Methods: We enrolled a prospective cohort of 103 patients with PHTN and 25 healthy controls between September 2017 and December 2018. All patients with PHTN underwent echocardiography and RHC. Patients were included if they underwent two-dimensional (2D) and 4D auto-RVQ echocardiographic sequences on the same day as RHC. We analyzed RV functional indices using 2D and 4D auto-RVQ analyses. We divided patients with PHTN into three groups according to echocardiographic image quality as follows: high (n = 24), average (n = 48), and poor (n = 4). Hemodynamic parameters were measured using RHC, including mean right atrial pressure, mean pulmonary arterial pressure, RV cardiac index (RV-CI), and pulmonary vascular resistance. Results: There were significant differences in most 2D and 4D auto-RVQ parameters between patients with PHTN and healthy controls. Interobserver variability showed significant agreement with 4D auto-RVQ for most measurements except for 4D end-diastolic volume. Indices measured by auto 4D-RVQ in the high-quality image group had a good correlation with RHC but not in the average- and poor-quality image group. Mid-RV diameter showed the best predictive power for the right RV-CI [area under the curve (AUC) 0.935; 95% confidence interval (CI), 0.714-0.997; p < 0.001]. RV end-systolic volume >121.50 mL had a 71.43% sensitivity and a 100% specificity to predict right RV-CI (AUC, 0.890; 95% CI, 0.654-0.986; p < 0.001). Conclusions: 4D auto-RVQ may be used to estimate RV function and some hemodynamic changes compared with RHC in PHTN patients with high image quality. Furthermore, a large sample of the study is needed to evaluate RV function by 4D auto-RVQ in PHTN patients with average image quality.
Frontiers in cardiovascular medicine 2021
BACKGROUND:Myocardial layer-specific strain can identify myocardial ischemia. Global myocardial work efficiency (GWE) based on non-invasive left ventricular (LV) pressure-strain loops is a novel parameter to determine LV function considering afterload. The study aimed to compare the diagnostic value of GWE and myocardial layer-specific strain during treadmill exercise stress testing to detect significant coronary artery disease (CAD) with normal baseline wall motion.METHODS:Eighty-nine patients who referred for coronary angiography due to suspected of CAD were included. Forty patients with severe coronary artery stenosis were diagnosed with significant CAD, and 49 were defined as non-significant CAD. Stress echocardiography was performed 24 h before angiography. Layer-specific longitudinal strains were assessed from the endocardium, mid-myocardium, and epicardium by 2D speckle-tracking echocardiography. Binary logistic regression analyses were performed to evaluate the association between significant CAD and echocardiographic parameters. A receiver operating characteristic curve was used to assess the capability of layer-specific strain and GWE to diagnose significant CAD.RESULTS:Patients with significant CAD had the worse function in all three myocardial layers at peak exercise compared with those with non-significant CAD when assessed with global longitudinal strain (GLS). At the peak exercise and recovery periods, GWE was lower in patients with significant CAD than in patients with non-significant CAD. In multivariable binary logistic regression analysis, peak endocardial GLS (OR: 1.35, p = 0.006) and peak GWE (OR: 0.76, p = 0.001) were associated with significant CAD. Receiver operating characteristic curves showed peak GWE to be superior to mid-myocardial, epicardial, and endocardial GLS in identifying significant CAD. Further, adding peak GWE to endocardial GLS could improve diagnostic capabilities.CONCLUSIONS:Both GWE and endocardial GLS contribute to improving the diagnostic performance of exercise stress echocardiography. Furthermore, adding peak GWE to peak endocardial GLS provides incremental diagnostic value during a non-invasive screening of significant CAD before radioactive or invasive examinations.
Frontiers in cardiovascular medicine 2021
To explore the value of right ventricular (RV) parameters detected by three-dimensional echocardiography (3DE) in risk stratification in pulmonary arterial hypertension (PAH) patients. We prospectively recruited 130 pulmonary hypertension patients from National Center for Cardiovascular Diseases, Fuwai Hospital. Each participant was performed a transthoracic echocardiography and 3DE parameters were measured using an off-line software (4D RV Function 2.0, TomTec). Patients were classified into low, intermediate-high risk group based on 2015 ESC Guidelines. A total of 91 PAH patients (34 ± 12 years old, 25 males) were enrolled, among which, 42 were classified into low risk group, while 49 were intermediate-high risk group. Compared with low-risk patients, those with intermediate-high risk had significantly larger 3DE-RV volumes, worse ejection fraction (EF) and tricuspid annular plane systolic excursion, and decreased longitudinal strain (LS). Receive operating characteristic curves illustrated all the 3DE parameters were able to predict intermediate-high risk stratification, especially 3D-RVEF (area under curve, 0.82, 95% CI 0.73-0.91, P < 0.001). And 3D-RVEF < 26.39% had a 81.6% sensibility and 73.8% specificity to predict intermediate-high risk stratification. Univariate and multivariate Logistic regression analyses identified 3D-RV end-diastolic (OR 1.02, 95% CI 1.01-1.03, P = 0.002) and end-systolic (OR 1.03, 95% CI 1.01-1.04, P < 0.001) volumes, 3D-RVEF (OR 0.82, 95% CI 0.75-0.90, P < 0.001) and LS of free wall (OR 1.17, 95% CI 1.05-1.31, P = 0.005) as independent predictors of intermediate-high risk stratification. In conclusion, RV volumes, EF and free wall strain detected by 3DE were independent predictors of intermediate-high risk stratification in PAH patients, among which, RVEF showed the best predictive capacity.
The international journal of cardiovascular imaging 2020
BACKGROUND:The 2016 guidelines for left ventricular diastolic dysfunction diagnosis has been simplified from previous versions; however, multiparametric diagnosis approach still exists indeterminate left ventricular diastolic dysfunction category. Left atrial (LA) strain was recently found useful to predict elevated left ventricular (LV) filling pressures noninvasively. This study aimed to (1) analyze the diagnostic value of LA strain for noninvasive assessment of LV filling pressures in patients with stable coronary artery disease (CAD) with preserved LV ejection fraction (LVEF), using invasive hemodynamic assessment as the gold standard, and (2) explore whether LA strain combined with conventional diastolic parameters could detect elevated LV filling pressures alone.METHODS:Sixty-four patients with stable CAD having LVEF > 50% and 30 healthy controls were enrolled. Two-dimensional speckle-tracking echocardiography was used to measure LA strain during the reservoir (LASr), conduit, and contraction phases. LV end-diastolic pressure (LVEDP), as a surrogate for LV filling pressures, was invasively obtained by left heart catheterization. Logistic regression was used to calculate the odds ratio to predict LV filling pressures. Pearson's correlation was used to analyze associations between echocardiographic parameters and LVEDP. The area under the receiver-operating characteristic curve was calculated to determine the capability of the echocardiographic parameters to detect elevated LVEDP. Inter-technique agreement was analyzed by contingency tables and tested by kappa statistics.RESULTS:LASr and the ratio of early-diastolic transmitral flow velocity (E) to tissue Doppler early-diastolic septal mitral annular velocity (E/E'septal) significantly predicted elevated LV filling pressures. LASr was combined with E/E'septal to generate a novel parameter (LASr/E/E'septal). LASr/E/E'septal had the best predictive ability of elevated LV filling pressures. LVEDP was negatively correlated with LASr and LASr/E/E'septal but positively correlated with E/E'septal. The area under the receiver-operating characteristic curve of LASr/E/E'septal was higher than that of LASr alone (0.83 vs. 0.75), better than all conventional LV diastolic parameters. Inter-technique agreement analysis showed that LASr/E/E'septal had good agreement with the invasive LVEDP measurement, better than the 2016 guideline (kappa = 0.63 vs. 0.25).CONCLUSIONS:LASr provided additive diagnostic value for the noninvasive assessment of LV filling pressures. LASr/E/E'septal had the potential to be a better single noninvasive index to predict elevated LV filling pressures in patients with stable CAD and preserved LVEF.
Cardiovascular ultrasound 2020
BACKGROUND:Models of intracardiac thrombus are very difficult to establish and have rarely been reported. We designed and established a new, inexpensive, practical animal model for intracardiac thrombus created with epicardial echocardiographic guidance.METHODS:Male New Zealand white rabbits weighing 2 to 3.9 kg (3.10±0.58 kg) were used in this study. Cylindrical thrombi were created in plastic tubing and then aspirated with saline into a syringe. The thrombus in saline suspension was then slowly injected into a heart chamber and confirmed with echocardiography, including two-dimensional and contrast-enhanced ultrasound.RESULTS:Intracardiac thrombi were created successfully in the left ventricle, right ventricle, and left and right atrial appendages. The average preparation time was about 3 hours. There were no significant differences among the four heart chambers in the success rate of thrombus model creation. Thrombi embolized to the pulmonary artery after failure of the right heart model. After failure of the left heart model, emboli were found in the carotid artery, renal artery, and truncus coeliacus. In two cases thrombi extended from the left ventricular apex into the aorta and in one case the thrombus extended from the left atrial appendage to the left atrium; there was no such extension from the other chambers. The rabbits' vital signs remained stable after establishment of the model, with no significant changes in heart structure or function.CONCLUSIONS:This new method of creating an intracardiac thrombus model in rabbits showed initial success.
American journal of translational research 2019
To investigate and compare the value of right ventricular longitudinal strain detected by two-dimensional and three-dimensional speckle-tracking echocardiography in risk stratification evaluation in pre-capillary pulmonary hypertension. We consecutively screened 66 patients diagnosed with pre-capillary pulmonary hypertension in our center. According to the risk assessment recommended by 2015 European Society of Cardiology Guidelines, all participants were classified into low- and intermediate-high-risk group. Two-dimensional and three-dimensional strains were measured using off-line softwares (GE EchoPAC version 201 and TomTec, 4D RV Function 2.0). Fifty-seven pre-capillary pulmonary hypertension patients (average 35 years old, 18 males and 39 females) were finally enrolled in our study, 32 (56.1%) were classified in low-risk group, while 25 (43.9%) were in the intermediate-high-risk group. Clinical data associated with disease severity, such as N-terminal pro-brain natriuretic peptide (r = 0.574, P < 0.001), peak oxygen consumption (r = -0.484, P < 0.001), and 6-min walking distance (r = -0.356, P = 0.008) were significantly correlated with two-dimensional right ventricular longitudinal strain; while the correlations with three-dimensional right ventricular longitudinal strain were weaker. Receiver operating characteristic curves for the detection of intermediate-high risk stratification showed two-dimensional right ventricular longitudinal strain had the best predictive capacity (area under curve, 0.82, 95% CI: 0.71-0.93, P < 0.001). Univariate and Multivariate Logistic regression analyses identified two-dimensional right ventricular longitudinal strain as an independent predictor (OR: 1.42, 95% CI: 1.18-1.71, P < 0.001) of intermediate-high risk stratification in this cohort of pre-capillary pulmonary hypertension patients, the predictive capacity retained (OR: 1.45, 95% CI: 1.18-1.78, P < 0.001) after adjusted by age, gender, and body mass index, while three-dimensional speckle-tracking echocardiography parameters were not. In conclusion, when used for the detection of intermediate-high risk stratification in pre-capillary pulmonary hypertension, two-dimensional right ventricular longitudinal strain was better than three-dimensional right ventricular longitudinal strain.
Pulmonary circulation 2019