赵鑫

中国医学科学院阜外医院 血管外科

[Chronic Debakey I aortic dissection in Marfan syndrome and hypertensive patients with modified stented elephant trunk surgery: a post-operative CT assessment].

OBJECTIVE:To assess the outcome of stented elephant trunk surgery for chronic DebakeyIaortic dissection in Marfan syndrome and hypertension patients by CT.METHODS:Between 2003 and 2008, 54 patients underwent the modified stented elephant trunk procedure and total arch replacement for chronic DebakeyIaortic dissection. Twenty-two patients were made a diagnosis of Marfan syndrome and the other 32 patients of hypertension. Aortic evolvement was evaluated with CT angiography by calculating the diameter ratios between the stent graft/true lumen and the aorta at the same level.RESULTS:CT study one year after discharge showed no difference in the diameter ratios of the stent and aorta at the carina level between groups (0.84 +/- 0.16 vs 0.80 +/- 0.23, P = 0.472), but had significant difference before and after surgery (0.29 +/- 0.16 vs 0.72 +/- 0.21, P < or = 0.001). And significant difference occurred at the different periods after discharge (0.72 +/- 0.21 vs 0.81 +/- 0.20, 0.81 +/- 0.20 vs 0.77 +/- 0.20, P < or = 0.001). The residual false lumen in the proximal descending aorta reached complete thrombosis in 59% of Marfan and 78% of hypertension.CONCLUSION:The modified stented elephant trunk technique is effective for closing the false lumen in the proximal descending aorta of chronic DebakeyIaortic dissection in Marfan syndrome and hypertension patients.

第一作者

Zhonghua yi xue za zhi 2010

Early influence of valve-related anticoagulation on false lumen thrombosis in aortic dissection patients after stented elephant trunk surgery.

BACKGROUND:Aim of the study was to assess the influence of anticoagulation on the false lumen after a stented elephant trunk procedure with mechanical valve replacement for aortic dissection patients.METHODS:Between 2003 and 2008, 181 out of 232 aortic dissection patients undergoing stented elephant trunk procedure concomitant with arch and/or proximal surgery were enrolled in this study. Fifty-five patients received an aortic valve replacement (AVR) with mechanical prosthesis. Patients were divided into two groups: with and without AVR. The aorta was evaluated by CT, and the diameter ratios between the true lumen and the aorta were calculated and the extent of thrombosis of the false lumen was quantified.RESULTS:Follow-up CT study at one year showed a significant difference between groups, mainly in the diameter ratios of the stent and aorta at the same level (P=0.003, at the stent end). Accordingly, CT data after hospital discharge differed significantly with regard to the extent of false lumen thrombosis at the carina level (P=0.020, at one year). Over one year after surgery, the residual false lumen around the stent-graft achieved complete thrombosis obliteration in 87.3% of patients with AVR and in 98.4% without AVR (P=0.005).CONCLUSIONS:Valve-related anticoagulation is associated with delay in false lumen thrombosis around the stent-graft.

0.3
第一作者

The Thoracic and cardiovascular surgeon 2010